Installation and Operating Instruction

2. Installation

3. Detection area 

6. Settings carried out using remote control (optional)

Remote control LUXOMAT

®

 IR-PD

1. Check Battery:

 

open battery compartment by pressing the 

plastic springs together and removing the 

battery-holder.

2.   IMPORTANT 

Please pay attention, that the setting is Potentio-

meter 1 at “TEST” and Potentiometer 2 

not

 at 

“SUN”. All values which have been program-

med using the remote control will be deleted in 

the event of power failure in the position “TEST/

SUN”. Please switch Potentiometer 2 over to 

“MOON” or any other value.

Caution:

 

Settings with remote control supersede the 

settings by courtesy of potentiometers.

LUXOMAT

®

PD5-M-1C-Clip

 1. Mounting preparations

Work on the 230 V mains supply 

may only be carried out by qualified 

professionals or by instructed persons 

under the direction and supervision of 

qualified skilled electrical personnel 

in accordance with electrotechnical 

regulations.

Disconnect supply before installing!

When in Master/Slave mode of 

operation, the Master-appliance must 

always be installed at the location 

where there is least daylight.

The product enters an initial 60-second 

self-test cycle, when the supply is first 

connected. The occupancy detector is 

ready for operation.

4. Self test cycle

The 

LUXOMAT

®

 PD5-M-1C-Clip is supplied 

with a 90 cm long, 5 x 0.75, colour-coded 

cable and is pre-wired. 

The detector has been specially developed 

for clipping onto fluorescent lamps of size 

T5+T8.

It is particularly suitable for use with 

suspended light-strips or for ceiling appli-

cations where holes caused by installation 

are to be avoided. Two clip sizes of the 

type required are enclosed. Carry out the 

clipping-on procedure as follows: 

The height-adjustable clip can be inserted 

in the housing easily as long as the mark-

ings on the clip-shaft and the housing are 

in line with each other. Once the correct 

distance to the light has been established, 

lock the shaft by rotating through 90° in 

an anti-clockwise direction.

Option:

Wall bracket for remote 

control IR-PD

IR-PD

IR-PD-Mini

5. Putting into operation / Settings

Follow-up time for light control

 The time can be set infinitely variably at between 

15 sec. and 16 min. 
 Symbol 

TEST

: test mode (every movement switches on 

the light for a period of 1 second, switching it off for a 

period of 2 seconds after that regardless of the level of 

brightness)

 

Twilight-switch for light control (relay 1)

The switch-on value for the light can be set at between 10 

and 2000 Lux. Using the rotary control, the luminance set 

points can be set as desired.

Symbol

 

Night-time operation

 

Symbol

 

:   Daytime/Night-time operation

Mounting 

height

Range (circular detection) T=18°C 

seated

walking 

across

walking 

towards

2.00 m

r = 2.00 m

r = 4.00 m

r = 2.00 m

2.50 m

r = 2.50 m

r = 5.00 m

r = 3.00m

3.00 m

r = 3.00 m

r = 6.00 m

r = 3.70 m

3.50 m

r = 7.00 m

r = 4.30 m

4.00 m

r = 8.00 m

r = 4.80 m

4.50 m

r = 9.00 m

r = 4.50 m

5.00 m

r = 10.00 m r = 6.00 m

GB

Reset when open: 

Deletes all values 

set with the 

remote control; 

the settings on 

the potentiometer 

apply

Unlocking device

or

or

Lock device

Permanent tamper protection 

Fully automatic/semi automatic 

mode (see page 2, point 5)

max

50

Lux

1500

Lux

ON

OFF

��

���

����

���

��

���

��

���

max

50

Lux

1500

Lux

ON

OFF

t < 5 s

Settings for relay 

Channel 1: 

Settings for master with remote control

Note: 

The buttons for channel 2 (

R2

) have 

no function for the PD5-M-1C-Clip.

��

���

��

���

Target value for brightness

Automatic reading in of the current light value

as a new target light value

Lag times for channel 1

Pulse function for channel 1, 

1s every 9 s on motion detection

The pulse function can only be selected in fully automatic mode.

Activate test mode when closed

To deactivate: 

press reset

Resetting when closed

The lighting relay is switched off, i.e. 

opened and the follow-up times reset.

Permanent protection against sabotage 

This function blocks the unit permanently (green LED is 

illuminated). This operating mode can only be activated 

during the period of 5 seconds after pressing the “lock“ 

button. This status will only permit actuating the function 

“Light on/Light off”. The procedure for leaving this mode is as 

follows:

 

1. Switch off the current

 2. 

Apply current for 31 - 59 seconds (green LED flashes)

 3. 

Switch of the current again

 4. 

Apply current, wait for selftest cycle

 5. 

Open detector

Light on/off when closed

The light will remain switched on/off for as long as move-

ments are detected in the areas of coverage. Once the last 

movement has been detected, the light will remain on for the 

duration of the follow-up time as per setting. 

The appliance will then return independently to the mode 

selected (Fully or Semi-automatic).

��

���

����

���

Explanation of button functions

max

50

Lux

1500

Lux

ON

OFF

t < 5 s

120 60 50

40

30

15

10

A

16 10

5

2

1

30

15

TEST

2000

1200

600

200

40

5