5. USER INTERFACES
Continued from the previous page
Address
Access
Description
0xF306
-/W
Bits 7-3: AN1 – switching time of measurement circuit
•
0
→
1/64 sec
•
1
→
2/64 sec
..
.
•
30
→
31/64 sec
Bits 2-0: AN1 – number of samples for averaging
•
0
→
one sample
•
1
→
two samples
•
2
→
four samples
•
4
→
eight samples
•
5
→
sixteen samples
...
0xF400
-/W
AN2 – sampling period [sec]
0xF401
-/W
AN2 – multiplicative constant (with sign)
0xF402
-/W
AN2 – additive constant (with sign)
0xF403
-/W
AN2 – hysteresis value (with sign)
0xF404
-/W
AN2 – lower limit (with sign)
0xF405
-/W
AN2 – upper limit (with sign)
0xF406
-/W
Bits 7-3: AN2 – switching time of measurement circuit
•
0
→
1/64 sec
•
1
→
2/64 sec
..
.
•
30
→
31/64 sec
Bits 2-0: AN2 – number of samples for averaging
•
0
→
one sample
•
1
→
two samples
•
2
→
four samples
•
4
→
eight samples
•
5
→
sixteen samples
...
0xF500
-/W
CNT1 – Multiplicative constant
0xF501
-/W
CNT1 – Upper limit
0xF502
-/W
CNT1 – Time of limit exceeded [sec]
0xF503
-/W
CNT1 – Time for resetting measurement [sec]
...
0xF600
-/W
CNT2 – Multiplicative constant
To be continued on the next page