IE
-MultiWay
44
LOOPBACK TESTING
The IE-MultiWay includes Loopback testing functionality. This feature is selectable via
iView2 within the OAM AH configuration. The menu choices for all ports includes:
•
Terminate/initiate
•
Process/ignore
OAM Loopback is controlled by using the “Loopback” and “Ignore Rx” control parameters.
Selecting “Initiate” from the “Loopback” control tells the client to start a loopback process
with the peer. Selecting “Process” from the “Ignore Rx” control tells the client to process
received loopback commands.
Only AH “Active” units can send a Loopback command to a remote unit. Either Active or
Passive AH units can respond to a Loopback command, but must be configured to
process these commands or they will be ignored.
Select Loopback to display loopback data and define how loopback is configured:
Select Event Log to display the OAM event log showing fault changes that have occurred
via OAM configuration:
The OAM Event Log table displays a history of the threshold crossing events and non-
threshold crossing events that have occurred at the Ethernet OAM AH Level. There is a
maximum of 8 events that can be displayed. When the maximum number of events is
reached older entries are deleted to make room for newer entries.
Содержание IE-MultiWay
Страница 1: ...IE MultiWay USER MANUAL ...
Страница 37: ...IE MultiWay 37 BANDWIDTH Select Bandwidth to display configure bandwidth settings for each port ...
Страница 41: ...IE MultiWay 41 AGENT INFO Select Agent Info obtain data on IP address firmware version and other info ...
Страница 45: ...IE MultiWay 45 Select Statistics to display OAM statistics ...
Страница 58: ...IE MultiWay 58 PRODUCT APPLICATION ...