background image

—–  10 —– 

INSTALLER REGISTRATION FORM

 

Please complete and return this form to Kinetic Electronics Limited. 

We can then send you any updated product information, current promotions etc.  

 

 

Name:

 

 

 

 

 

 

 

     Position:

 

Company:

  

 

 

 

 

 

     Tel:

 

Address:

   

 

 

 

 

 

     Fax:

 

 

 

 

 

 

 

 

 

     E-Mail:

 

 

 

Post Code:

 

 

Which distributors do you 

 

 

1. 

regularly buy from? 

 

 

 

 

 

 

 

2. 

 
 

 

 

 

 

 

3. 

 

 

 

 

 

 

 

 

 

 

 

 

How many Alarm Systems do you install each month?

 

 

How many of the following ‘Kinetic’ products do use each month?  

 

 
 

 

 

 

EXTERNAL SOUND UNITS

 

 
 

 

 

 

SLA BATTERIES

 

 
 

 

 

 

MYLAR EXTENSION  SPEAKERS

 

 

 

 

 

 

 

 

 

 

SOUND BOMBS 

 
 

 

 

 

ALARM CABLE

 

 
 

 

 

 

CCTV CAMERA SYSTEMS

 

 

 

Please complete and Fax to 0161 654 9596, Post to the address overleaf  

or email [email protected].   

Many Thanks! 

 

 

………………………………………………………………………………………………………………………………………………………………………

Содержание AZ-120

Страница 1: ...AZ TECH EXTERNAL SOUNDERS Quality through People products INSTALLATION GUIDE...

Страница 2: ...al Sound Unit Sounder Connections Page 4 Set up and Operation procedure Page 5 Indications of Alarm status Flashing LED indicators Installing Multiple Units Connecting two or more units Page 6 Safety...

Страница 3: ...alone SAB SCB operation and trickle charge of the battery when a hold off voltage is applied SAB SCB SAB Self activating Bell unit The standard sounder operating mode providing maximum sounder volume...

Страница 4: ...of the cardboard outer box and insert wall plugs Affix the Sound Unit backplate to the exterior wall ensuring that your connecting cable has been inserted through the appropriate cable entry hole INST...

Страница 5: ...ront cover over the backplate and locate into position You should hear the click of the microswitch depressing as the cover locates Secure with the fixing screw provided and insert the protective scre...

Страница 6: ...from the Control Panel ie as a result of someone cutting the connecting cable to the Sound Unit or due to total loss of Power to the Control panel INSTALLING MULTIPLE UNITS If more than one Sound Unit...

Страница 7: ...e their own method of testing the strobe and siren which should be utilised Failing that simply arm the system and cause an alarm activation to confirm correct operation of the External Sound unit Tem...

Страница 8: ...Panels AZTECH ESU SABT TAMP RTN BELL BELL TR HO SUPPLY HO SUPPLY STR STROBE Connections For A1 OMNICRON MICROMARK STROBE NOT CONNECTED AZTECH ESU SCB RT TAMP RTN BELL BELL TR BELL SUPPLY SCB A SUPPLY...

Страница 9: ...ST ST Connections For PYRONIX Control Panels Paragon E Plus Conqueror Super Sterling 10 Matrix Euro AZTECH ESU TAMP RTN BELL TR SUPPLY SUPPLY STROBE Castle BT BT BT TR BA BELL NO PGM1 NO BELL B S or B...

Страница 10: ...ingle Piezo Single Piezo Twin Piezo Strobe Xenon tube 90 flashes min 90 flashes min 90 flashes min Indication Twin LED Twin LED Twin LED SAB SCB YES YES Timer Panel determined 15 9 minute cut off 5 se...

Страница 11: ...s Fax E Mail Post Code Which distributors do you 1 regularly buy from 2 3 How many Alarm Systems do you install each month How many of the following Kinetic products do use each month EXTERNAL SOUND U...

Страница 12: ...Kinetic Electronics Limited Unit 7 Stakehill Industrial Estate Middleton Manchester M24 2RW Tel 0161 654 9595 Fax 0161 654 9596 Email sales kinetic security co uk www kinetic security co uk RoHS...

Отзывы: