PG. 6 EDGEWINDER
GETTING STARTED
ALL MACHINES:
1. Check oil & filters. Read
Engine Operation
Manual.
Your first oil change should be done
at 5 hours.
2. LPG tanks should only be filled by
authorized agents. Tanks should be filled by
weight
, not by volume. A filled tank will run
6-8 hours.
3. Connect LPG tank to hose (see:
OPERATION
#4 in left hand column of this
page).
4. Open propane (LPG) tank valve (counter
clockwise).
5. Set throttle control at idle for 12 V & choke
for electric start.
6. 12 volt system — turn key to the “Start”
position & move throttle toward “Fast”
position. If engine does not start, release key
and return to step #5. If hard starting, refer to
step #1.
7. Electric Start — push “Start” button till
engine starts. Starter should not be
engaged for more than 10 seconds at a
time. If hard starting is a problem refer to
#1.
8. All machines are equipped with tamper
proof fuel systems. If a fuel problem exists,
contact an authorized service center.
9. All machines are equipped with a multi-function
maintenance meter. The functions include the
following: hours, service alert and tachometer.
(See
Engine Maintenance Meter
).
ENGINE MAINTENANCE METER
This multi-function meter acts as a preventive
maintenance tool, which benefits you with
increased fuel economy, less down-time and
longer engine life.
The meter’s displays are:
Hour Meter:
Displays total run hours when
machine is off.
Tachometer:
Indicates engine RPM during
operation.
Service Alert:
The display flashes to alert you
to lube and change the oil at 25 hour intervals.
The service alert only flashes during operation
and it warns you to change the oil for only two
hours. After the two hours is reached, the alert
will automatically reset to the next 25 hour
interval. Therefore, it is recommended that a
separate maintenance log be kept to track oil
changes.
EDGEWINDER OPERATION
To transport machine, pull in reverse or push
forward by raising brush off floor.
Adjust handle to comfortable position. To
obtain maximum control, operate with handle
over engine.
Start engine with the throttle in the choke
position. The clutch will disengage when
throttle is moved to the slow position (1500
RPM).
Engage the brush by moving the throttle past
1/4 (1900 RPM). Brush should be replaced
when bristle length reaches 1/2".
Operate engine throttle at: 1/2 for Scrubbing
3/4 for Stripping
KEEP MACHINE MOVING TO AVOID
FLOOR DAMAGE.
EDGEWINDER CLEAN-UP
To access underside of machine, tip to right (as
viewed from operator position).
Rinse underside of machine after use.
Brush should be replaced when bristle length
reaches
1/2".
EDGEWINDER MAINTENANCE
Brush Replacement
1. Access underside.
2. Remove 4 nuts with a 9/16" wrench or
socket.
3. Remove brush.
4. Replace washers and nuts.
Belt Replacement
1. Access underside.
2. Remove brush.
3. Remove belt from idler pulley and engine
sheave.
4. Pull belt out from driveshaft area.
5. Reverse procedure for replacement.
EDGEWINDER PG. 3
WARNING!
!
NOTES