Azbil NX-SVG Скачать руководство пользователя страница 7

E1

CP-UM-5928JE

Network Instrumentation Modules 

Smart Device Gateway 

Model NX-SVG 

Installation Manual

Thank you for purchasing an Azbil Corporation product.
This manual contains information for ensuring the correct use 

of this product. 
This manual should be read by those who design and main-

tain equipment that uses this product.
Be sure to keep this manual nearby for handy reference.
Please read “Terms and Conditions” from the following URL 

before ordering and use.
https://www.azbil.com/products/factory/order.html

NOTICE

Be sure that the user receives this manual before the product is used.
Copying or duplicating this user’s manual in part or in whole is 
forbidden. The information and specifications in this manual are 
subject to change without notice.
Considerable effort has been made to ensure that this manual is 
free from inaccuracies and omissions. If you should find an error or 
omission, please contact the azbil Group.
In no event is Azbil Corporation liable to anyone for any indirect, 
special or consequential damages as a result of using this product.

SAFETY PRECAUTIONS

Safety precautions are for ensuring safe and correct use of 

this product, and for preventing injury to the operator and 

other people or damage to property. You must observe these 

safety precautions. Also, be sure to read and understand the 

contents of this user’s manual.
If this equipment is used in a manner not specified by the 

manufacturer, the built-in protection provided by the equip-

ment will be impaired.

 

z

Key to symbols on the side of the case

 WARNING

Warnings are indicated when mishandling this prod-

uct might result in death or serious injury to the user.

 CAUTION

Cautions are indicated when mishandling this product 

might result in minor injury to the user, or only physi-

cal damage to this product.

 WARNING

Before removing, mounting, or wiring this device, be sure 

to turn off the power to the device and any connected 

devices.  

Failure to do so might cause electric shock.

 WARNING

Be sure to check that this device has been correctly 

wired before turning on the power. Incorrect wiring of 

this device may lead to hazardous conditions or device 

failure.

 CAUTION

Install or remove the DIN rail locking tab using a tool 

such as a screwdriver. Otherwise, you might be injured.
Do not disassemble this device.  

Doing so might cause device failure.
Do not block ventilation holes.  

Doing so might cause fire or device failure.
Do not allow wire clippings, metal shavings or water to 

enter the case of this device.  

They might cause fire or device failure.
Do not touch live parts such as the power terminals. 

Doing so might cause electric shock.
Before wiring this device, except when connecting net-

work cables, be sure to turn off the power. 

Failure to do so might cause device failure.
Wire this device correctly by using the wiring method, 

power, and installation method specified in this user’s 

manual. 

Failure to do so might cause electric shock, fire or de-

vice failure.
Make sure that there are no loose connections. Failure 

to do so might cause overheating or device failure.
Supply power to all linked modules from the same 

power source. Using two or more power sources can 

cause fire or faulty operation. 
Do not use unused terminals on this device as relay 

terminals. Doing so might cause electric shock, fire or 

device failure.
Firmly tighten the terminal screws to the torque listed 

in the specifications. Insufficient tightening of terminal 

screws might cause electric shock or fire.
If there is a risk of a power surge caused by lightning, 

use a surge absorber (surge protector) to prevent fire or 

device failure.
Use this device within the operating ranges given in the 

specifications (temperature, humidity, voltage, vibra-

tion, shock, mounting orientation, atmosphere, etc.). 

Failure to do so might cause fire or device failure.
This device should be handled by a specialist with ex-

pertise in electrical safety. 

Otherwise, there is a danger of electric shock.
If this device is used in the manner not specified by the 

manufacturer, the protective function of the device may 

be impaired.
When removing dirt from the device, never use an or-

ganic solvent such as thinner or benzene, or a detergent. 

Doing so might cause device failure.
Make sure that devices and equipment connected to 

this device have reinforced insulation suitable for the 

maximum operating voltage of this device’s power sup-

ply and input/output components. 

Failure to do so might cause electric shock, fire or de-

vice failure.
Use a battery that meets the specifications given in this 

document. Otherwise, there is a danger of fire or device 

failure.

Содержание NX-SVG

Страница 1: ...J1 CP UM 5928JE NX NX SVG URL https www azbil com jp product factory order html DIN 2 NX SVG NX SVG 1 CP UM 5928JE...

Страница 2: ...ROR ID F1 F2 RUN MOD COM NST FAIL 1 0 ID USB LAN1 RS 485 CH1 DA DB SG LAN2 LAN RS 485 RS 485 CH2 1 DC24 V 2 DC24 V RS 485 CH2 4 DA 5 DB 6 SG LED PWR ON OFF RUN MOD COM LAN2 LAN2 NST LAN2 LAN2 LAN2 LAN...

Страница 3: ...J3 15 m 30 Vrms 42 4 V DC60 V LAN RS 485 RS 485 CH2 DIN DIN DIN DIN DIN DIN 2 mm...

Страница 4: ...uit 1 25 mm2 16AWG 30 m M3 5 8 mm 0 6 N m 1 70 W LAN1 LAN2 LAN1 RJ 45 LAN2 RS 485 CH1 RS 485 CH2 RS 485 CH1 DA SG DB RS 485 CH1 RS 485 CH2 1 2 4 5 6 DA DB SG 150 5 1 2 W SG USB USB USB USB 1 LED USB R...

Страница 5: ...V 0 3 2 m s2 10 150 Hz XYZ 2h 0 9 8 m s2 3 0 3 mg m3 2000 m Pollution degree 2 20 70 5 95 RH 0 9 8 m s2 10 150 Hz XYZ 2h 0 300 m s2 DIN 3 60 cm 1 3 6 DC500 V 20 M I O AC500 V 1 min I O 6 W 10 A 30 s...

Страница 6: ...il com jp 0466 20 2143 2018 2 F 2019 4 5 V LAN 2 LAN1 LAN2 IEEE802 3 10BASE T 100BASE TX AutoMDI MDI X RJ 45 100BASE TX UTP 4P Cat 5e ANSI TIA EIA 568B 100 m RS 485 2 RS 485 CH1 RS 485 CH2 1 31 RS 485...

Страница 7: ...ing tab using a tool such as a screwdriver Otherwise you might be injured Do not disassemble this device Doing so might cause device failure Do not block ventilation holes Doing so might cause fire or...

Страница 8: ...power LAN and RS 485 of adjacent modules Does not connect RS 485 CH2 terminals Power supply terminal 1 24 V DC 2 24 V DC RS 485 CH2 terminals 4 DA 5 DB 6 SG These terminals cannot be connected with th...

Страница 9: ...S 485 CH2 terminals cannot be connected Connection of modules must be done before they are mounted on the DIN rail When connected modules share the power and communication connections eliminating the...

Страница 10: ...the LAN1 and LAN2 connectors Insert an RJ 45 connector into the LAN1 connector on the de vice The side connectors on the base are LAN2 connectors Connecting to RS 485 CH1 and CH2 Connect wires to the...

Страница 11: ...stance 0 m s2 Mounting angle Reference plane 3 z z Operating conditions Ambient temperature 0 to 50 C below the installed module Ambient humidity 10 to 90 RH without condensation Allowable power suppl...

Страница 12: ...500 m No of wires 3 Terminating resistor External 150 0 5 W min Transmission speed Selectable from 4800 9600 19200 38400 57600 and 115200 bps Data bits 7 bits 8 bits Stop bits 1 bit 2 bits Parity bit...

Страница 13: ...Sie vor dem Einschalten des Ger ts unbedingt ob es sachgerecht verdrah tet wurde ACHTUNG Die folgenden Vorsichtshinweise sind zu beachten um elektrische Schl ge Feuer und andere Gefahrenzust nde zu ve...

Страница 14: ...ssere osservati al fine di prevenire scosse elettri che incendi e altre condizioni pericolose Prima di rimuovere montare o cablare questo dispositivo accertarsi di disatti vare l alimentazione di ques...

Страница 15: ...sor el rango y los par me tros seg n corresponda para el objetivo de control Aseg rese de que el terminal de tierra del bastidor est correctamente puesto a tierra 100 m x antes de conectar el controla...

Страница 16: ...X4 MEMO...

Отзывы: