39
Chapter 7. SPECIFICATIONS
Item
Specifications
Insulation resistance
Between each terminal and flow path metal parts: min. 50MΩ
(500Vmegger dc)
Protection
IP54 (JIS C 0920) splash-proof and dustproof structure
Applicable standards
EN61010-1: 2010
EN61326-2-3: 2013, EN61326-1: 2013 (To be used in an industrial
electromagnetic environment)
During EMC testing, the reading or output may fluctuate by the
equivalent of ± 8 % FS.
Over-voltage category
Category II
Pollution degree
Pollution degree 2
Altitude
2000m or less
*1
: Factory adjustment is done on the basis of the 13A-46MJ/m
3
gas composition shown in the
table below. When used with 13A-45MJ/m
3
gas, change the value of parameter
GaS.C
(gas
composition compensation coefficient) to 1.029.
Gas type
(as used by Azbil Corporation)
Calorific value
MJ/m
3
(N)
Methane
(%)
Ethane
(%)
Propane
(%)
Butane
(%)
Fuel gas 13A-46MJ/m
3
46.04655
88
5.8
4.5
1.7
Fuel gas 13A-45MJ/m
3
45.007
88.9
6.8
3.1
1.2
When used for fuel gas with a different composition than the above, contact the azbil Group.
*2
: Propane gas composition: propane 98%, (class B)
*3