(2) Set the communications settings
as shown:
Transmission speed (B): 9600
Date length (D):
8
Parity (P):
Odd
Stop bit (S):
1
Flow control (F):
Xon/Xoff
Then, click the
[OK]
button.
(3) Click the
[Settings]
tab seen in
step (1), and the screen shown in
the figure below will appear.
Click the
[ASCII Settings]
button.
(4) Configure the settings as shown
below and click
[OK]
. The screen
returns to that shown in step (3).
Click
[OK]
again.
■
Specifications
■
External dimensions
■
Panel cutout dimensions
A. S. OUT
SW.OUT
ch
1
2
3
4
40
27.6
35.4
32
40
Note: Dimensions exclude mounting
part and mounting retainer
70
70
45
+0.6 0
45
+0.6
0
Unit: mm
Unit: mm
Item
Specification
Flow rate display
7 segment LED, 3 digit display
Flow rate display
Selectable from: disabled, 2, 4, and
moving average function
8 times
(shown every 125 ms)
•
Disabled: no moving average display
•
Twice: average of 2 flow rates every
125 ms
•
4 times: average of 4 flow rates every
125 ms
•
8 times: average of 8 flow rates every
125 ms
Output indication (SW.OUT) Red LED lights up when output is ON
Auto scan channel
Green LED for the displayed
display
channel lights up
Console keys
: up,
: down,
: mode
Communications
RS-232C communications
Operating temperature -10 to +50°C (without condensation
without freezing)
Storage temperature
-20 to +80°C (without condensation
without freezing)
Dielectric strength
500Vac 1min
Insulation resistance
100M
Ω
or more (500Vdc megger)
Vibration resistance
88.3 m/s
2
(total amplitude 1.5mm 10 to
55Hz)
Shock resistance
490 m/s
2
(non-repeated shock)
Case material
PBT
Mass
Approx. 45g (without cables)
Item
Specification
Power
24Vdc +/- 10%
Supply voltage for flow 24Vdc +/- 10%
sensor
Current consumption
100mA max (not including flow sensor
current)
Applicable sensor type MCS100A100 (-3 to 3 L/min)
MCS100A104 (0 to 3L/min))
MCS100A108 (-500 to 500mL/min)
MCS100A112 (0 to 500mL/min)
MCS100A120 (0 to 10L/min)
Number of connected
1 to 4
sensors
Input voltage range
1 to 5Vdc
Maximum applied voltage 5.3Vdc
Number of outputs
4
Output type
NPN open collector
Response time
3 ms (Response time before the switch
output turns on is variable and can be
selected from 3, 20, 100, and 1000 ms.)
Load voltage
30Vdc or less
Load current
50mA or less
If a load current exceeding 70 mA
continues for 5 ms or longer, error
E-2n
is displayed by the overcurrent
protection function.
Internal voltage drop
0.3V max. (with 5mA load current)
Operation mode
Window comparator modes 1 to 4
Output mode
Effective only in window comparator
(inverted / direct)
mode 4
Hysteresis
Variable (set to "2" or more)
Voltage
Sensor input
Switch output
Display
Setting method
General
Specifications are subject to change without notice.
(09)
1-12-2 Kawana, Fujisawa
Kanagawa 251-8522 Japan
URL:
http://www.azbil.com
1st edition: Oct. 2006 (U)
3rd edition: Apr. 2012 (M)