*1 Item in ( ) is for the case of direct ignition. 
*2 Visible light flame detector and contact input are 35s only. 
*3 Visible light flame detector and contact input model do not have the low fire shutdown function. 
*4 During postpurge after a warning, no reset input is accepted until postpurge is complete. 

Also, reset input is not accepted if no warning has occurred. 

Transporta- tion 

and stor- age 

condi- tions 

Ambient tempera- ture 

-20 to +70°C 

Ambient humidity 

5 to 95 % RH (no condensation) 

Vibration 

0 to 9.8 m/s

2

 (10 to 150 Hz, 1 octave/minute, 10 cycles, in each of XYZ directions) 

Shock 

0 to 300 m/s

2

 

Packaged drop test 

60 cm drop height (free drop onto 1 corner, 3 edges, 6 sides) 

Operating 

conditions 

Ambient tempera- ture 

-20 to +60 °C 

Ambient humidity 

10 to 90 % RH (no condensation) 

Vibration 

0 to 3.2 m/s

2

 (10~150Hz, 1 octave/minute, 10 cycles, in each of XYZ directions) 

Shock 

0 to 9.8 m/s

2

 

Mounting angle 

Reference plane +/-10 ° 

Dust 

0.3 mg/m

3

 or less 

General 

specifications 

Protective structure 

IP40 (with a sideboard ( 81447515-001) attached to the sub-base (BC-R05)) IP10 (sub-base 

(BC-R05) only) 

Excess voltage cat- 

egory 

II 

Pollution degree 

PD2 

Case color 

Black 

Case material 

Denatured PPE resin (UL94-V0 PTI materials group IIIa) 

Structure 

Sub-base and main unit 

Mounted 

orientation 

Vertical or horizontal 
However, in horizontal mounting the 7-segment display must face directly upward (DIN rail 

mounting or direct mounting through base screw holes) 

Standards 

JIS C 9730-2-5 
EN 298 (0063BS1427) 

Dimensions 

W95 × H105 × D110 mm 

Weight 

Approximately 600 g (incl. sub-base) 

Wiring types and max. wiring length 

-

 

Start, airflow switch, lockout interlock, POC (shutoff valve proof of closure), low fire interlock, high fire interlock Copper IV wire 

with 600 V vinyl insulation, 1.25 mm

2

, recommended condition: 20 m or less, 

maximum wiring length: 100 m 

-

 

Contact reset 

Copper IV wire with 600 V vinyl insulation, 1.25 mm

2

, maximum wiring length: 10 m 

- AUD100/110/120 (F, G) 
Copper IV wire with 600 V vinyl insulation, 1.25 mm

2

, maximum wiring length: 100 m 

-

 

Flame rod (F, G) 

RG-11U (JAN standard: US DoD compliant specification) or equivalent, 5C2V, 7C2V (JIS standard) Recommended condition: 20 m 

or less, maximum wiring length: 30 m 
- AUD100/110 (F, G) 
Copper IV wire with 600 V vinyl insulation, 1.25 mm

2

, maximum wiring length: 10 m 

-

 

RS-485 communications (3-wire system) 

0.2 to 1.5 mm

2

 shielded, twisted pair cable (recommended) Maximum wiring length: 500 m 

- Signal line for flame voltage output 
IV wire, 0.75 mm

2

 or larger, max. wiring length 10 m 

Содержание BC-R35 Series

Страница 1: ...ng codes PresstheDISPswitchtodisplaytheflamevoltage External statusoutput States such as ignition failure flame failure and combustiondetectedareoutputdigitally andusedas panel displays Warning reset...

Страница 2: ...or 1 800 Vac for 1s Between each terminal and ground except for combustion sensor connection terminals terminals 14 15 Insulation resistance At least 50 M 500 Vdc megger Between each terminal and gro...

Страница 3: ...R05 only Excess voltage cat egory II Pollution degree PD2 Case color Black Case material Denatured PPE resin UL94 V0 PTI materials group IIIa Structure Sub base and main unit Mounted orientation Vert...

Страница 4: ...n record with data Flame detector Visible light flame detector AFD100 110series I II III IV V VI VII Example BC R35A7G0500 I II III IV V VI VII Description Base model number Commu nications function F...

Страница 5: ...e rod holder Discontinued C7008A Flame rod assembly Discontinued Visible light flame detector Model number Name Notes AFD100A0700 Visible light flame detector Light reception direction front top view...

Страница 6: ...t for5secondstoensureoperationstability 2 During postpurge reset is disabled for 20 seconds Connector for front wiring 81447514 001 terminal layout Connectorforfrontwiring forrightsidewiring 81447514...

Страница 7: ...hreeminutesafterhighfire position output Low fire interlock error 1 The low fire interlock turned off between pilot ignition and main stabilization Low fire interlock error 2 The low fire interlock re...

Страница 8: ...nput in isolation It cannot be used in conjunction with other BC R contact reset inputs Outputcommon terminals4 5 andinputcommon terminal16 17 cannotbeusedinconjunctionwithotherBC Rcontactreset inputs...

Страница 9: ...44 70 10170 02 888 3472 08 08 170 170 02 888 3258 https www add furnace com E mail sales add furnace com For compliance with the standard on remote control of boilers Standards circular No 0331001 wh...

Страница 10: ...rew Model number A 81447514 001 10 6 81447514 002 14 6 Sub base BC R05A100 sold separately 61 Sub base sold separately 95 110 Connector for front wiring Sub base sold separately BC R main unit fasteni...

Страница 11: ...02 888 3472 08 08 170 170 02 888 3258 https www add furnace com E mail sales add furnace com Sideboard 81447515 001 sold separately Unit mm 30 7 Sub base Sub base 19 knockout hole Sideboard Sideboard...

Страница 12: ...BC R Main unit BC R Main unit Installation orientation Install the device in the orientation shown below Display area OK OK Do not install it in the orientations illustrated below Mounting in a Panel...

Страница 13: ...tion Flameout No ignition Lockout interlock Start check time Approximately 2 s Pre purge time Ignition standby time Main stabilization time Main ignition time Postpurge time Pilot ignition time Pilot...

Страница 14: ...ctromagnetic breaker Ignition transformer Main valve Lo solenoid valve Main valve Hi solenoid valve Warning output Control motor open Control motor closed Control motor proportional Monitor output Com...

Страница 15: ...etic breaker Ignition transformer Main valve Lo solenoid valve Main valve Hi solenoid valve Warning output Control motor open Control motor closed Control motor proportional Monitor output Combustion...

Страница 16: ...ector AFD100 series contact input For a UV sensor Write the model No With a visible light flame detector Write the model No Ignition method circle the applicable product Direct ignition type time limi...

Страница 17: ...ut notice 1 12 2 Kawana Fujisawa Kanagawa 251 8522 Japan https www azbil com 13 1stEdition Oct 2014 3rd Edition Dec 2020 No part of this publication may be reproduced or duplicated without the prior w...

Отзывы: