Azbil 5LX7 A1 Series Скачать руководство пользователя страница 10

4

Chapter 3.  INSTALLATION AND ADJUSTMENT

This section describes how to install the limit switch.

 WARNING

Never leave or use the limit switch when the cover is off. Doing so may cause an explosion resulting in 
serious harm.

 CAUTION

Do not remove the cover or the plug from the limit switch until you are ready to do the wiring. If dust 
or liquid enters the switch, poor operation, poor electrical contact, or insulation failure may result.

After wiring is complete, do not leave the limit switch with its cover off. If dust or liquid enters the 
switch, poor operation, poor electrical contact, or insulation failure may result.

Before using for the first time, keep the whole limit switch protected with a dustproof and waterproof 
sheet. Substances like cement or paint stuck to the switch may cause the lever to malfunction.

Do not leave the limit switch in an atmosphere containing gases that can adversely affect the contacts 
and/or other materials (H

2

S, SO

x

, etc.). Exposure to such gases can cause contact failure.

Do not allow the limit switch seal to come into contact with solvents (benzene, kerosene, alcohol, etc.) 
that may adversely affect them. Contact may lead to poor functioning or insulation failure.

Do not stand on the limit switch, place heavy objects on it, or strike it. Never apply a force 5 times 
greater than the operating force (O.F.) to the switch lever. Failure to observe these precautions may re-
sult in faulty operation.
Before using a sealing agent, locking agent, etc., on the conduit joint, make sure that it will not gener-
ate fumes that will damage the contacts.

Make use of heat insulating material, a shielding plate, etc., in mounting the limit switch so that its tem-
perature will not exceed the working temperature range as a result of radiant heat or heat conduction.

Take appropriate protective countermeasures if the limit switch is installed in a location subject to con-
tinuous vibration or impact.

Содержание 5LX7 A1 Series

Страница 1: ...al should be read by those who design and maintain equipment that uses this product Be sure to keep this manual nearby for handy reference User s Manual for Gas Vapor Explosion Proof Increased Safety...

Страница 2: ...anual are subject to change without notice Considerable effort has been made to ensure that this manual is free from inaccuracies and omissions If you should find an error or omission please contact t...

Страница 3: ...or physical damage to the product In describing the product this manual uses the icons and conventions listed below Use caution when handling the product The indicated action is prohibited Be sure to...

Страница 4: ...al conditions for the safe use of this limit switch in hazardous atmospheres are de scribed in the product specification sheet Use this limit switch within the allowable ranges for each characteristic...

Страница 5: ...mit switch 2 Model selection table 2 Chapter 3 INSTALLATION AND ADJUSTMENT 4 Installation 5 How to change the head orientation 7 Chapter 4 WIRING 8 Chapter 5 ADJUSTMENT 11 Points to check before begin...

Страница 6: ...Memo...

Страница 7: ...standard type 10 to 100 C H type 40 to 60 C L type 10 to 60 C if stored using protective plug s 8 Storage humidity range 98 RH max if stored using protective plug s 9 Protective structure IP54 IP67 1...

Страница 8: ...0 1 _ _ _ _ Basic model No Conduit Contact material Environment Material Specifications 5LX7001 Actuator type roller plunger J G1 2 straight thread increased safety conduit type A1 G1 2 straight thre...

Страница 9: ...Ltd Sealing fitting Nipple Limit Switch Increased safety packing type EXPC 16B series packing type cable gland made by Shimada Electric Co Ltd Explosion proof packing type cable grand Limit Switch Inc...

Страница 10: ...mosphere containing gases that can adversely affect the contacts and or other materials H2S SOx etc Exposure to such gases can cause contact failure Do not allow the limit switch seal to come into con...

Страница 11: ...et AD17024E Packing type cable gland for 5LX7 _ _ _ A1 _ _ _ increased safety packing type limit switch Choose a packing type cable gland from the EXPC 16B series made by Shimada Electric Co Ltd makin...

Страница 12: ...ccur Dog OK Dog About the actuating object The roughness and hardness of the object s surface significantly affects the operat ing life of the switch The following specifications are recommended Rough...

Страница 13: ...nged or the head is removed the diaphragm seal may come loose Plunger Diaphragm seal Procedure 1 Remove the head mounting screws 2 Change the direction of the head and reattach it 3 Tighten the head m...

Страница 14: ...reads and secure with a lock nut If waterproofing is required apply sealant to the screw threads For explosion proofing be sure to use a sealing fitting to connect the conduit to the switch and apply...

Страница 15: ...e same for both single wire and two ply or more stranded wires Attaching the cover Be sure to attach the cover after wiring is complete Tighten the four cover mounting screws evenly in a diagonal patt...

Страница 16: ...ing a packing type cable gland for 5LX7 _ _ _ A1 _ _ _ increased safety packing type limit switch AD specifications sheet AD18142E Mounting a packing type connector for 5LX7 _ _ _ R _ _ _ increased sa...

Страница 17: ...or flexible piping Adjustment 1 To adjust the operating position of the limit switch change the position of the actuating object or of the limit switch 2 To ensure reliable operation set overtravel O...

Страница 18: ...g the limit switch firmly tighten the cover and conduit Insufficient tightening because of corrosion etc not only results in the loss of sealing and insulating performance but also nullifies the switc...

Страница 19: ...er mounting screws Check for damage to the cover Tighten mounting screws if they are loose See chap 4 P 9 for tightening torque In other cases replace the limit switch 4 Housing External damage Visual...

Страница 20: ...itch specifications see the specifications sheet The relevant specifications sheet numbers are shown below To acquire them contact the azbil Group Model No Specifications sheet No 5LX700_ _ _ _ _ AD18...

Страница 21: ...360E Printed Edn Revised pages Description Jan 2013 1 July 2013 2 Overall revision 2nd ed 3th Jp ed Mar 2017 3 End of the manual Overall revision 3rd ed 4th Jp ed Terms and Conditions were changed to...

Страница 22: ...documents provided by Azbil Corporation are for your reference purpose only and you are required to check the functions and safety of your Equipment prior to your use 3 Measures to be taken to secure...

Страница 23: ...struments sensors such as pressure flow level sensors regulating valves etc will reach the end of their life due to aged deterioration of parts For those parts that will reach the end of their life du...

Страница 24: ...09 Specifications are subject to change without notice 1 12 2 Kawana Fujisawa Kanagawa 251 8522 Japan URL http www azbil com 1st edition Jan 2013 V 3rd edition Mar 2017 F...

Отзывы: