background image

USER MANUAL

 _

 4

INTRODUCTION

Thank you for selecting the AYRTON VERSAPIX-RS luminaire.

WARNING !

This product is not suitable for household use.

You now own a professional lighting unit that offers endless possibilities. 
Before installing, make sure that no damage was done to your luminaire 
during transport. If this is the case, do not use the product and immediately 
contact your authorized AYRTON dealer.

For your own safety and that of others, please read this instruction manual 
carefully before installing the unit.

Anyone involved in installing, operating or servicing the VERSAPIX-RS 
must:

 

•  Be a qualified, authorized professional

 

• Strictly follow the instructions in this user manual.

Please take the time to read this manual carefully and thoroughly before 
installing and operating the luminaire. You should have a good knowledge 
of its operating conditions and all pertinent product information.

After you have become familiar with this manual, we recommend that 
you keep a copy for future use. All the information found in this manual 
is subject to change without notice. AYRTON reserves the right to modify 
and upgrade its range of products, with no obligation to integrate these 
changes into products already sold.

SAFETY INSTRUCTIONS

Please read the safety instructions and warnings in this manual carefully 
before installing and operating the VERSAPIX-RS.

WARNING!

Risk of electric shock.

Use caution when handling. This luminaire requires high voltage,

which can result in electric shock.

The VERSAPIX-RS left our factory in perfect working condition. However, if 
you notice a defect, immediately contact your authorized AYRTON dealer 
before use. The manufacturer cannot be held responsible for damages 
caused by a failure to follow the safety, installation or assembly instructions 
contained herein, or by any modification made to the luminaire.

Failure to observe the safety, installation or assembly instructions 
contained herein, or any modification made to the VERSAPIX-RS luminaire 
will render the warranty null and void.

Check that the supply voltage does not exceed the maximum authorized 
limit. Check that your electrical installation complies with current 
standards.

In all cases, make sure that the power cables attached to your VERSAPIX-
RS have not been damaged due to cuts and splices or crushed in any way. 

Handle these cables with extreme caution while they are connected to a 
power source.

Your VERSAPIX-RS conforms to Class 1 safety standards. The unit must 
be grounded electrically. Make sure that the power source connected to 
your VERSAPIX-RS is switched off before attempting any work on it.

Installation and connection to an electrical source must be performed 
by an authorized installer. AYRTON declines all responsibility should this 
luminaire be installed by an unqualified person.

Installation and connection to an electrical source must be performed 
by an authorized installer. AYRTON declines all responsibility should this 
luminaire be installed by an unqualified person.

Never disconnect your VERSAPIX-RS by pulling on the power cable! 
First unlock the connector lock ring on the power cable until it is fully 
disengaged, and then gently pull on the connector to disconnect the cable.

Do not connect or disconnect the power cable of your VERSAPIX-RS with 
wet hands.

At first use, your VERSAPIX-RS may give off an odor. This is a normal 
occurrence that should dissipate after a few minutes of operation.

WARNING!

Do not connect or disconnect the power cable at your VERSAPIX-RS 

if the cable is energized! This could cause arcing and damage your 

VERSAPIX-RS, requiring repair.

Be careful to power off your VERSAPIX-RS by removing the power plug 
from the source, before connecting or disconnecting the luminaire.

WARNING!

This unit contains Class 2 LED emitters (EN60625-1): 1994)

This luminaire uses five (Class 2) LED-type (Light Emitting Diode) lamps. 
Never look directly into the lamps if lit or stand directly in line with the 
luminaire if close by.
Installation, removal or replacement of the unit must be performed with 
power off to prevent any risk of glare and eye injury.

WARNING!

The fixture quickly becomes very hot during operation.

To avoid risk of burn, never handle or adjust the luminaire while it is 
energized and after it has been lit for more than 10 consecutive minutes. 
Some parts of the luminaire can reach a high temperature, particularly the 
body/radiator. Turn off the luminaire and wait for it to cool before handling.

CONDITIONS OF USE

Your VERSAPIX-RS is a static luminaire equipped with 5 LED intended for 
professional use (e.g., architectural, stage, television, theater, or museum 
lighting).

Содержание VersaPix-RS

Страница 1: ...USER MANUAL V 1 1 ENGLISH VERSION 21 06 2016...

Страница 2: ......

Страница 3: ...n and features Dimensions Description Installation instructions DMX512 connection Control Panel VersaPix RS control panel menu Option details Master Slave Mode settings DMX Chart Error Messages Care a...

Страница 4: ...wer cables attached to your VERSAPIX RS have not been damaged due to cuts and splices or crushed in any way Handle these cables with extreme caution while they are connected to a power source Your VER...

Страница 5: ...glass that fall on the unit may cause breakage of the plastic parts or the body AYRTON cannot be held responsible for the luminaire s broken plastic parts or body which are not covered under warranty...

Страница 6: ...mantled or serviced The operator must ensure that a qualified technician has approved the installation of the luminaire for safety before it is first operated Installation should be inspected once a y...

Страница 7: ...rol information sent by the DMX controller The start address must conform to the one recorded on the DMX controller to run the luminaire This address is the DMX value that appears on the luminaire s d...

Страница 8: ...home screen ADDRESS SET DMX ADDR Allows you to change a DMX address from the fixture s control panel w w Access the menu by pressing the Mode Esc key w w Go to the ADDRESS menu and press Enter then f...

Страница 9: ...enu by pressing the Mode Esc key w w Use the up down arrow keys to reach the OPTION menu and press Enter Then use the left right arrow keys to access the Temp C F submenu w w Use the left right arrow...

Страница 10: ...ion of the fixture w w Access the menu by pressing the Mode Esc key w w Use the up down arrow keys to reach the INFO menu and press Enter Then use the left right arrow keys to access the Software ver...

Страница 11: ...u Example Program 2 includes scenes 10 11 12 13 Program 4 includes scenes 8 9 10 Program 6 includes scenes 12 13 14 15 Auto Program Part 1 is Program 2 Auto Program Part 2 is Program 3 Auto Program Pa...

Страница 12: ...Mode Channel Value Function St Ba Ex 10 6 Chase Patterns 0 15 Led trun off 16 31 Chase 1 32 47 Chase 2 48 63 Chase 3 64 79 Chase 4 80 95 Chase 5 96 111 Chase 6 112 127 Chase 7 128 143 Chase 8 144 159...

Страница 13: ...istorted in any way or show any trace of corrosion The safety cable should be attached at the appropriate spot Mechanical parts should show no sign of wear The electrical cables should show no sign of...

Страница 14: ...iagram A A 750 325 220 R 3 0 WARRANTY The AYRTON VERSAPIX RS fixture is guaranteed against manufacturing defects for the duration of one 1 year from the date of purchase This warranty does not cover t...

Страница 15: ...USER MANUAL _ 15...

Страница 16: ...www ayrton eu...