17
controller which connected.The fixture can log in the wireless transmitter
,
and receive only
radio signal from transmitter
,
but not DMX from the transmitter.
OFF
:(
De-activate WDMX
)
In this status
,
wireless system is not activated
,
so the fixture can not log in the transmitter.
REST
:(
reset WDMX memory
)
Can remove the fixture from the connection with the transmitter
,
the fixture become free and
ready to log in any transmitter.
9.4
Setup the wireless system
:
1)
Connect the transmitter with the DMX controller.
2)
To make the fixture installed with wireless receiver log in to the transmitter.
a)
Initially
,
the indicator on the receiver fixture should be in Solid red.
b)
Press and hold the configuration button on transmitter for less than 3 seconds the
red/green LEDs on the transmitter and the receiver fixture will flash rapidly for about
5~ 10 seconds while the system goes through its setup procedure.
c)
Once the receiver fixture is logged in to the transmitter
(
T1
),
the fixture with wireless
receiver will keep the memory
,
even if restart the power
,
this unit will log in the
transmitter
(
T1
)
automatically.
3)
Use the DMX 512 to control the fixture
9.5
Remove the receivers from transmitter
(
T1
)
and to log in to another transmitter
(
T2
):
Case 1
:
Remove a receiver
:
a)
On the control board of the fixture
,
enter menu to activated the function of REST
;
b)
The LED for wireless on the fixture should turn to Solid red; the receiver can log out from
the transmitter
(
T1
);
c)
press the configuration button on transmitter
(
T2
)
for less than 3 second
,
then the fixture
will start to connect with the transmitter
(
T2
)
.
Case 2
:
Remove all receivers from a transmitter
(
T1
)
to log in to T2
:
a)
Press and hold the configuration button on the T1 as least 5 seconds
,
can clear the
connection with all the fixtures
;
b)
All the red/green LEDs on the receiver fixtures will turn to Solid red to indicate that the
receivers are unassigned and removed from the transmitter
(
T1
);
c)
Press and hold the configuration button on the T2 less then less than 3 second
,
the fixtures
will connect with the T2.
PS
:
1.
Please log the receivers out from the transmitter after every job
,
so that the receivers are in
free un assigned state and ready to be assigned to a transmitter.
2.
Do not connect the fixture which is under the communication of wireless system to the
DMX controller
,
otherwise it will cause interference from the DMX controller.