background image

 

 

Installation and maintenance 

Mounting the bracket 

A pre-mounted dual hanging bracket is provided, with screwknobs at both side of the brackets. These 
brackets can be used to install the unit to a fixed structure, such as a T-bar or truss.  

NOTE: 

Always use both mounting points when installing this fixture! 

 

Installing the fixture in a hanging position 

When you wish to position the fixture against a wall, ceiling or beam, make sure to use proper 
installation tools and let a skilled technician install the fixture for you.  
 
When you wish to install the fixture to a lighting stand or truss system, use a G-clamp or halfcoupler 
for optimal, safe and stable fixation. Check the technical specifications of your light stand or truss 
system to gather more information on maximal loads and other safety precautions.

 

 

Transport 

When using this fixture in mobile setups, provide sufficient protection during transport. Use the original 
packaging of this unit, or use a professional flightcase with proper foam inlay. This way the electronics, 
optics and housing are protected against severe shocks, exterior damage and failing electronics.  
 

Replacing the internal fuse 

First check whether a failing power supply may be the cause of malfunction. When you suspect that 
the internal fuse is broken, the fuse can be replaced by removing the fuse cover, located directly next 
to the power in/outlet.  

 
WARNING: 

Before changing the fuse, always disconnect the fixture from your wall outlet or any other 

power supply to prevent electric shocks. 
Always replace a broken fuse with a fuse that has the same type and rating. After the fuse has been 
replaced, always close the fuse-cover. Reconnect the fixture to your power supply and check whether 
the problem is solved. When this does not solve your problem, contact your local dealer for help. 
 

Spare parts 

This unit has no user serviceable parts inside. When any damage to internal components occur, 
contact your local dealer or a specialized technician in order to repair the fixture. 
 

Cleaning: 

 

Clean the housing of the fixture frequently with a damp cloth, to remove dust and/or dirt. 

WARNING: 

Always disconnect the fixture from your wall outlet or other power supply and let the fixture dry before 
reconnecting it. This prevents possible electrical shocks. 
 
The lenses can be cleaned with a non-aggressive glass cleaning solution, but is not recommended. 
Ayra recommends to clean the mirror and lens with a fine brush, while removing dust and/or dirt with a 
vacuum cleaner. Avoid touching the lenses with your bare fingers, to prevent fingerprints on the optics.

 

 
Checkup 

To prevent dangerous situations, make sure your fixture is in optimal condition before using it. Check 
your fixture frequently by using the following checklist: 
- All screws must be mounted tightly.  
- Check all screws and metal parts for corrosion. No visible corrosion may be present. 
- The exterior of your fixture must be in optimal condition. Check your fixture for dents, cracks or 
missing parts.  
- Your installation spot must be in optimal condition. Check your installation spot for corrosion, cracks, 

Содержание TDC 4 LED

Страница 1: ...1 DMX LED light effect with 4 lenses User manual ...

Страница 2: ...t Direct installation with proper bolts is also possible Make sure there are no flammable objects in the direct environment of the device Do not block the beam exit Keep a minimum distance of 0 25 meter from any walls to provide sufficient cooling Make sure the beam exit is not blocked by any objects in the near environment Always use the included power supply Contact your local dealer for a repla...

Страница 3: ...disconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with the unit do not connect it to a power source When you suspect that your unit is broken or damaged contact your local dealer or a certified technician to inspect the unit When your device does not generate any light do not look ...

Страница 4: ...view 1 Beam output 2 Adjustable bracket 3 IEC Power inlet outlet 4 Control panel display with MENU UP and DOWN buttons 5 Built in microphone for sound active mode 6 DMX input 3P XLR 7 DMX output 3P XLR 8 Fuse holder ...

Страница 5: ...gures on a standard speed AUT1 Gobo effect 1 AUT2 Gobo effect 2 AUT3 Gobo effect 3 AUT4 Gobo effect 4 AUT5 Gobo effect 5 AUT6 Gobo effect 6 AUT7 Gobo effect 7 AUT8 Gobo effect 8 AUT9 Gobo effect 9 AUTA Gobo effect 10 AUTB Gobo effect 11 SOU1 Master fixture sound active displayed through ON OFF status SLAD Slave function SLA1 Slave function 1 SLA2 Slave function 2 ADDR DMX address function to set t...

Страница 6: ...n in doubt contact your local dealer for advice Set the correct address on the digital display you are able to choose a value between 001 and 512 DMX channel control Channel 1 0 100 dimmer value 0 255 Channel 2 0 100 dimmer value 0 255 Channel 3 0 100 dimmer value 0 255 Channel 4 0 100 master dimmer value 0 255 Channel 5 Strobe speed slow to fast value 0 255 Channel 6 Auto select pattern value 0 2...

Страница 7: ...ture from your wall outlet or any other power supply to prevent electric shocks Always replace a broken fuse with a fuse that has the same type and rating After the fuse has been replaced always close the fuse cover Reconnect the fixture to your power supply and check whether the problem is solved When this does not solve your problem contact your local dealer for help Spare parts This unit has no...

Страница 8: ...ialized technician Do not use a damaged or failing fixture Connectors and wiring schematics DMX connections Electrical wiring Power supply This unit must be connected to a 230V AC 50 60 Hz power source The fixture is provided with an IEC in and outlet making it possible to distribute power easily over several fixtures without the need of extra power strips The fixture is capable of powering up to ...

Страница 9: ...rnal microphone Working modes music controlled DMX automatic test master slave LCD display with menu buttons Included power cable Electronic dimmer for each color master dimmer Power consumption 30 Watt Power supply 230V AC 50 Hz Measurements 990 x 210 x 170 mm with bracket Weight 4 5 kg Connectors DMX 3p XLR male and female Power IEC power connector inlet outlet Included accessories Power cable w...