15
NOISE
Noise values measured according to relevant standard. (K = 3)
Acoustic pressure level L
pA
69.9 dB(A)
Acoustic power level L
wA
89.9 dB(A)
ATTENTION! The sound power level may exceed 85 dB(A), in this
case individual hearing protection shall be worn.
16
PERFORMANCE TESTING
Frequency of performance testing and inspection:
1. Daily
Safety valve
Check the safety
valve for correct
operation by
pulling on the red
knob.
The safety valve is set to the maximum
allowable pressure of the pressure tank. It is
not permitted to adjust the safety valve or
remove its seal.
Drain valve
Check for any
visible problem .
It is necessary to clean this drain valve and
remove dust and dirt.
2. Weekly
Pressure tank
Check for any
visible problem.
A pressure tank may not be operated if it has
defects that pose a risk to employees or third
persons.
The pressure tank should be regularly
checked for damage, such as rust.
If you discover damage, please contact the
customer service centre.
3. Monthly
Intake filter
This filter should be cleaned at
least every 100 operating
hours.
The filter can be appropriately
removed.
JLVWB6L (1330985)
|
11
EN
Содержание 1330985
Страница 2: ...JLVWB6L 1330985 FIG 1 Abb 1 DE 00 1 2 3 4 5 6 7 8...
Страница 20: ...JLVWB6L 1330985 FIG 1 Abb 1 FR 00 1 2 3 4 5 7 6 8...
Страница 38: ...JLVWB6L 1330985 FIG 1 Abb 1 IT 00 1 2 3 4 5 7 6 8...
Страница 56: ...JLVWB6L 1330985 FIG 1 Abb 1 EN 00 1 2 3 4 5 7 6 8...
Страница 73: ...CH Import Distribution exklusiv durch Jumbo Markt AG 8305 Dietlikon WWW AYCE CH Tel 044 805 61 11...