background image

Complete * Schaumburg, IL  60173 * 

Phone:  

888

-

392

-

9947

 

 3

 

TOOL SPECIFICATIONS

 

MODEL OF TOOL

………….……………………………………….. 

 

C

-

9040LM

 

DIMENSIONS

 (

L x H x W

………………….……………………...

 

12.08" x 2.29" x 10.15"  

 

WEIGHT 

WITHOUT FASTENERS

)

…………………………….

 

2.75 lbs

 

RECOMMENDED OPERATING PRESSURE

…..……..………...

 

70

-

120 PSI 

 

STAPLE SPECIFICATION

……………..…………………………..

 

18 Ga. 

1/4” 

narrow crown staples  

 

MAGAZINE CAPACITY

…………………………………………….

 

160 Staples

 

 

 

 

 

Содержание Complete ProGrade C-9040LM

Страница 1: ...RNING IMPORTANT PLEASE READ BEFORE USING TOOL Please read the following operating instructions manual Refer to this manual for safety adjustment and trouble shooting instructions If you have any furth...

Страница 2: ...92 9947 2 PAGE TOOL SPECIFICATION 3 SAFETY INSTRUCTIONS 4 COMPRESS AIR SYSTEMS 5 OPERATING INSTRUCTIONS 6 PRECAUTIONARY MEASURES 7 MAINTENANCE 8 TROUBLE SHOOTING 9 TROUBLE SHOOTING 10 EXPLODED VIEW OF...

Страница 3: ...7 3 TOOL SPECIFICATIONS MODEL OF TOOL C 9040LM DIMENSIONS L x H x W 12 08 x 2 29 x 10 15 WEIGHT WITHOUT FASTENERS 2 75 lbs RECOMMENDED OPERATING PRESSURE 70 120 PSI STAPLE SPECIFICATION 18 Ga 1 4 narr...

Страница 4: ...ularly inspect the safety the trigger and the springs for free unhindered movement never use a tool that requires servicing Connect the male free flow nipple to the tool side of the air line so that t...

Страница 5: ...uld be connected to the tool side of the system with the female coupling providing a seal to prevent air loss from the compressor tank upon disconnection Never connect a female disconnect coupling to...

Страница 6: ...ng the appropriate working equipment including safety goggles Firing a fastener to fire a fastener hold the nose of the tool against the work piece to depress the contact safety then pull the trigger...

Страница 7: ...piece the fastener can ricochet causing personal injury Remember always hold nose right up to and firmly against the work material Disconnect the tool from the air supply before performing any mainten...

Страница 8: ...for wear or damage Use non flammable cleaning solutions to wipe the tool Never soak the tool in these solutions as they can cause internal damage Always ensure that all of the screws are kept tight as...

Страница 9: ...ormal nail guide groove of Blade Guide deflected deformed or broken Load nails and confirm that they will move smoothly No nail is ejected Adhesive fragment or wood dust sticking on the Magazine or na...

Страница 10: ...g the tool Failure Possible causes Check Method Counter measures The driven nail is bent Nails are inaccurately fed into the Blade Guide Incorrect nails are loaded Refer to item above Refer to item ab...

Страница 11: ...Complete Schaumburg IL 60173 Phone 888 392 9947 11 NOTES...

Страница 12: ...Exploded View Diagram Mar 2018 C 9040LM A1 18 Ga Narrow Crown...

Страница 13: ...701 1 CYLINDER SPACER 1 415 2040500 02010 0 LOCK NUT 2 118 2041102 05010 0 O RING 1 416 2040302 22010 0 E RING 1 119 11322 0394701 1 CYLINDER RING 1 417 11337 0084701 1 SAFETY SPRING 1 120 11327 02647...

Страница 14: ...Visit our web site www axxisus com Or Email us reception inc axxisus com...