4. HF antenna:
The HF antenna helps the electric arc ignition. If the HF antenna is not well installed, it is possible that the
power supply will not be able to create the electric arc. You have to put the spring on the ceramic nozzle
and to fix the lug on a part linked to the ground. Pay attention that the electric arc does not ignite between
the antenna and a part linked to the electrode.
5. Connecting the weld head:
Ensure that the welding station is not activated before making these connections. SATO weld heads are
connected using a hose pack that includes:
A quick-release gas hose for connection at the front of the welding station.
Blue colour-coded (cold water) braided hose for the welding current with water coupling.
A red hose for hot water return.
A control cable for the feed motor.
An earthing cable.
An AVC-OSC cable
A wire cable