background image

Genetic guidelines

Avoid air pressure settings above 7 bars as this can 
damage the spray gun

Only use VACTAC200 hot melt adhesive with the 
spray gun. New adhesives will need to be qualified by 
R&D before use

NEVER

leave the gun lying on its side while turned 

on. This will cause adhesive to run back into the 
chamber and jamming the gun.

Prevent contamination of the adhesive slugs. 
Particles in or on the adhesive slugs can block the 
nozzle of the spray gun.

Always follow current guidelines for adhesive dosage. 
Over dosage can cause delamination's.

Always consult AXVAC before potential changes of 
nozzle type. 

Hot melt adhesive should not be used for full surface 
joining.

For large glass pieces it is recommended to join fix-
points in the glass and adhere the fabrics from these 
inside the mould as opposed to applying adhesive to 
the entire ply outside the mould.

Содержание TEC 7300

Страница 1: ...Index Introduction List of operations in this instruction Generic guidelines Opr 1 Check of gun settings Opr 2 Check of adhesive feed Opr 3 Spray of hot melt...

Страница 2: ...gun Prevent contamination of the adhesive slugs Particles in or on the adhesive slugs can block the nozzle of the spray gun Always follow current guidelines for adhesive dosage Over dosage can cause...

Страница 3: ...Check settings of TEC 7300 Step 1 0 Remove the rubber cap surrounding the nozzle WARNING Make sure to wear heat resistant gloves if removing the rubber cap while the gun is turned on...

Страница 4: ...e type is mounted in the gun The nozzle type can be identified by the color Red narrow spray fan recommended nozzle type Yellow Medium spray fan Blue Wide spray fan Don t forget that there is also the...

Страница 5: ...OK 1 6mm clearance NOT OK 1 6mm clearance...

Страница 6: ...un is still hot WARNING Always wear heat resistant gloves since both the nozzle cover and the nozzle is hot NOTE Put the spray gun on a piece of masking paper while repositioning the nozzle Hot adhesi...

Страница 7: ...s and firmly press the nozzle into the spray gun NOTE The gun MUST be hot when repositioning the nozzle Remount the nozzle cover with the pliers NOTE Make sure to check that nozzle cover clearance fro...

Страница 8: ...Check of adhesive feed Adjust the air pressure to 4 bars Max 7 bars...

Страница 9: ...The TEC 7300 Spray gun must be turned on for minimum 5 minutes before use...

Страница 10: ...roving material Adjust the adhesive dosage to 20 50 g min by turning the screw on the back of the spray gun NOTE The accurate adhesive feed is dependent on the desired movement speed of the gun Recom...

Страница 11: ...Spray on the hotmelt glue Example CSM roving Recommended Acceptable Not acceptable...

Страница 12: ......

Отзывы: