Ethernet Packet Generator
USER GUIDE
APG-UG-V2-1
31
8 February 2018
Button
Action
Opens the "File Load" window to select the load file name and location.
Alternatively the path and filename can be entered manually.
The path and filename default to the last used settings.
Disable/Enable Configuration change
Applies the saved configuration to the selected options
Refreshes the list of connected units
Closes the Load Configuration window without applying the changes.
Select the saved configuration file either by entering the path and filename (.apg extension)
manually or by clicking the
button to open the File Selection window to select the
directory and filename.
Opening the selected file automatically parses the saved configuration where the contents are
analysed to determine how many units were included in the saved configuration.
The saved 'GUI Layout' and 'Counter Selection' will be applied if the corresponding checkbox is
enabled. The stream configuration is always applied.
A list of saved serial numbers and unit types are displayed, with a corresponding 'apply' list of
currently connected units. The connected unit list can be updated using the
button.
The checkbox must be enabled to load the saved configuration onto the target unit.
The 'apply' unit does not have to be the same serial number or type, and saved ports will be
applied if the port exists on the target unit.
The configuration is applied to the APG Control Interface and connected units using the
button.
6.3.4
File - Exit
Closes the connections to APG units and close the Control Interface.
The APGs will continue to run and generate packets when the Control Interface is
not connected.