AXT ELECTRONIC VSE Скачать руководство пользователя страница 2

2 mm

Upper

outer

drill hole

Marten protection rail

(optional)

Lower

outer

drill hole

Lower

stop

Marten protection rail

(optional)

ASSEBLY

Electronic Doorkeeper VSE

1. Using a level, mount the lateral guide rail vertically. 

Align the upper hole towards the outside. If an optional 

protective rail is available, use it to mark the lower attach-

ment holes.  Align the protective rail horizontally.

2. Align the door and mark the position of the second 

guide rail. Ensure that there is enough side clearance for 

the door between the two guide rails. Attach the second 

guide rail. 

3.  Now connect the Doorkeeper VSE to the door (attach 

cord to door) and insert the door into the rails. Using 

the Doorkeeper VSE, bring the door into the desired 

upper position (door open). The cord of the Doorkeeper 

VSE must be exactly vertical.  Mark the position of the 

Doorkeeper VSE.  

4.  Unscrew the lid and attach the Doorkeeper VSE in the 

marked position.

5.  Mount all optional accessories such as external LED, 

external manual control or external twilight sensor (see 

wiring diagram on the next page).

START OF OPERATION

 

Electronic Doorkeeper VSE

1.  Remove the white plastic tab from the battery holder. If necessary, connect the optionally available power supply. The device goes through a start proce-

dure, which ends with  „Welcome...“. The display is then deactivated, and the Doorkeeper VSE is ready to accept entries.

2.  For the initial set-up, hold the red magnet against the „Menu“ control panel for 3 seconds. You will see various status messages one after the other.

3.  Now set the language, time and date via the menu operation. (Please refer to the explanations on the right.) 

The basic settings are now complete and the display is deactivated again. The Electronic Doorkeeper VSE is now immediately ready for use with the factory default 

settings. Test the closing and opening of the door by using the manual control (SA) to ensure a smooth operational procedure.

Factory Default Settings: The Doorkeeper VSE is preset to a combined, light-time control.  It opens daily at 8 o‘clock a.m., 

but only when it is light. In the evening the Doorkeeper VSE closes automatically when it gets dark, or at the latest, 10 o‘clock p.m.

General Information:

  A long battery life is guaranteed if you only use AA Mignon alkaline batteries! If the batteries in your new device last only a few days or 

weeks, there is most likely a mounting error (e.g. door blockage). Via manual operation with the red magnet,
 check to see if the door can be completely opened (limit switch contact in the Doorkeeper VSE).

Assembly Information: 

There should not be an upper stop or obstruction! Switching off during opening and closing is carried out via switches in the device. Door weight 

must be a minimum of 200 gr. And a maximum of 3.0 kg. The maximum stroke of the pulling cord is 70 cm. To prevent the door from freezing in winter, coat the rails with a 
small amount of lubricant. Neither the cord nor the inside of the Doorkeeper VSE is to be exposed to lubricants or directly lubricated. When installation is not directly possible 
or desired above the door, please observe the separate information on our website. To extend the connecting cord between the door and the Doorkeeper VSE, an additional 
cord may be used (without noticeable weight addition), but 

NOT

 a chain or carabiner, as the additional weight would result in the deactivation of the automatic switch-off 

when the door is closing.

The Doorkeeper VSE can be used in four different opera-

ting modes (each separately for morning and evening).

„LUX AND TIME“ Combined Controlling 

Light sensor and timer jointly control the opening and 

closing times. Opening in the morning when „light AND 

opening time reached“, closing in the evening when 

„dark OR closing time reached“.

„LUX ONLY“ Twilight Controlling

Only the light sensor controls the opening and closing 

times. In the morning it opens when the light sensor 

detects „light“, in the evening it closes when „no light“ 

is detected. This depends on the light sensitivity setting 

of the light sensor.

„TIME ONLY“ Time Controlling

The light sensor is deactivated via software. Only the 

switching times of the internal timer are active. Ope-

ning and closing times must be defined for automatic 

operation.

„MANUAL“ Manual Controlling 

Light sensor and timer are deactivated. Opening and 

closing can only be carried out with the manual control 

(SA).

Содержание VSE

Страница 1: ...he Electronic Doorkeeper VSE Please note the general information on the back of this sheet and the safety instructions in the manual AXT electronic GmbH Co KG Wartburgstrasse 10 99817 Eisenach GERMANY Phone 0049 3691 721070 service axt electronic de www axt electronic de ...

Страница 2: ...e evening the Doorkeeper VSE closes automatically when it gets dark or at the latest 10 o clock p m General Information A long battery life is guaranteed if you only use AA Mignon alkaline batteries If the batteries in your new device last only a few days or weeks there is most likely a mounting error e g door blockage Via manual operation with the red magnet check to see if the door can be comple...

Страница 3: ...f the polari ty is reversed the LED flashes red regularly after closing not green Manual Controlling SA Function Opening and closing of the door by holding the red magnet against the SA marking Twilight Sensor When using the out door light sensor ASb please unscrew the internal sensor or darken it comple tely with a black cap up to the screw terminal LED Indicators Device in Closed Mode 1x green L...

Страница 4: ...g for the opening mode there is a risk that the door will also be opened at night if there is strong moonlight or scattered light due to snow or outdoor lighting 10 Lux is for closing earlier in the evening and opening later in the morning Note With this maximum setting for the closing mode the door may also be closed during a heavy thunderstorm during the day The value for Open should be at least...

Страница 5: ...After approx 1h no further attempt is made to open Actuate the SA to get the device out of the error state It will close and you can remove the blockade Cord very tight in opened condition Limit stop does not work If the white limit switch is pulled extremely far towards the motor a component of the limit switch is defective Please send the device for repair Slider blocks during opening The limit ...

Страница 6: ...sion for repair 1 You cannot resolve the error using the table 2 Contact us if you are not sure what to send If possible send pictures of the devices in advance by e mail cover open assembly with door 3 We usually need the devices accessories such as external sensors or the timer together for repair 4 We do not need the aluminum door with us 5 Remove the devices from the installation site Remove t...

Страница 7: ...tronic GmbH Co KG Wartburgstraße 10 99817 Eisenach GERMANY Phone 0049 3691 721070 service axt electronic de www axt electronic eu Electronic Doorkeeper VSE First steps and basic settings in the menu navigation ...

Страница 8: ...ositioned on YEAR Year Month Day Use up or down to set current year Confirm with ok 8 Cursor is positioned on MONTH Year Month Day Use up or down to set current month Confirm with ok 9 Cursor is positioned on DAY Year Month Day Use up or down to set current day Confirm with ok The use ESC Back leads to canceling these three settings Default values then are applied These can have to be corrected la...

Страница 9: ...em returns to the Opening Mode menu item 6 Press down up to select a new menu item for setting or select and confirm the last menu item EXIT or wait 1 minute and do not operate anything to have the menu guidance end automatically d For closing set LUX ONLY mode close only at dusk no Time 1 activate the Menu hold Magnet for 3sec at OK Menu 2 Mark the menu item Closing Mode with 2x down Press Ok to ...

Страница 10: ...ith OK Use up down to select the LUX AND TIME mode if it is not set but is to be used Confirm the LUX AND TIME mode with OK if it has not already been set 5 Change the opening time selection from Monday Sunday MO SU with 1x down to Saturday Sunday SA SU With 1x OK place the cursor on the HOUR hh mm of the opening time 6 Use up and down to set the desired new opening time If no minutes are to be se...