![Axpert Max 3600 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/axpert/max-3600/max-3600_service-manual_3041280022.webp)
Service Manual
Product
Axpert Max 3600-24
Doc No.
P1911061
Version
00
PAGE
The C86 are (33uF 450V)
Parts
Attribute
Reference values
Failure status
F7
Resistor
0.1 ohm
Open or explosion
NTC4
Resistor
11.4 ohm
D68
Diode
+ to -: 0.458V
- to +:OL
Short or explosion
Q20
Resistor
GS: 45.27k
SD: 4.711K
Short or explosion
Diode
SD: 0.536V
SG: OL
Short or other
values
Q14
Resistor
BC: 361.9k
BE: 411.6k
Short or explosion
Diode
BC: 0.598V
BE: 0.611V
U12
Diode
PIN5 TO PIN7: 0.492V
PIN5 TO PIN6: 0.639V
Short or other
values
C86
Capacitance
33uF/450V
2.7 Check the bus soft start circuit (TX1: Especially for 09 fault)
The D6 is (RHRP8120 8A 1200V UFST)
The R29 is (RES 0.62 J)
The MOSFET Q3 is (IRFBG30 3.1A 1000V TO-220)
The D10 and D7 are (MUR4100ERLG 4A 1000V UFST)