0 4
A S S E M B L Y (see page 32)
S P A R E P A R T S (see page 35)
N O D R I N K I N G W A T E R
C L E A N I N G ⁄ O P E R A T I O N (see page 34)
⁄ The preservation of the water quality is in the operator’s responsibility! The
included treatment agent must be applied according to the manufacturer's
instructions. After using up the treatment agent, the operator must procure
suitable replacement on his own initiative! Source of supply of water treat-
ment products: www.katadyn.com
⁄ The water level must be checked daily!
⁄ The water must be changed regularly (every week)!
⁄ To guarantee a perfect function of the "AXOR ShowTec Fontana 60", the
reservoir must be cleaned regularly (every week).
⁄ If the water throughput rate is low, the filter must be cleaned.
D I M E N S I O N S (see page 31)
Do not use silicone containing acetic acid!
T E C H N I C A L D A T A
Nominal voltage:
230 V AC 50 Hz
Nominal consumption:
70 W
Protection class:
I
Protection category:
IPX4
Water temperature:
30°C max.
Serial number:
91212000 ⁄ 91214000 ⁄ 91215000 (see typeplate)
Dimensions:
see page 31
weight:
165 kg
Noise emission:
< 75 dB(A)
S A F E T Y N O T E S
I N T E N D E D U S E
The “AXOR ShowTec Fontana 60” must be used for the purpose of presentation
only.
It is not allowed to make arbitrary changes to this product! Use the "AXOR
ShowTec Fontana 60" only with Hansgrohe products! Application of products by
other manufacturers will void the warranty!
N O N - I N T E N D E D U S E
The "AXOR ShowTec Fontana 60" may not be used for bathing, hygienic and body
cleaning purposes!
A different or excessive use is considered non-intended. The user⁄operator bears
the sole risk. The intended use includes the adherence to the operating instructions
and the observance of the inspection and maintenance guidelines.
This appliance may be used by children aged 8 years and up and by persons
who are physically or mentally handicapped, have restricted sensory capabilities
or lack of know-how and experience, provided they use it under supervision or
have been given instructions on the safe use of the appliance and understand the
hazards involved. Do not allow children to play with the appliance. Do not allow
children to clean the appliance and do maintenance operations unless under
supervision.
The manufacturer⁄seller of this product does not assume any responsibility for
injuries or damage that may be caused by improper installation or non-intended
use.
E L E C T R I C A L I N S T A L L A T I O N
E L E C T R I C I A N
Installation and tests are to be performed by an approved electrician, taking DIN
VDE 0100-718 into account. It's a Legal Requirement for the Installation and wiring
to conform to current IEE Electrical and Building regulations.
A safety check must be performed according to DGUV V3.
E L E C T R I C A L C O N N E C T I O N
Voltage supply: 230 V⁄N⁄PE ⁄50-60 Hz
The connection of the “AXOR ShowTec Fontana 60” must be carried out via an
easily accessible socket or an all-pole mains switch.
R E S I D U A L C U R R E N T P R O T E C T I O N S Y S T E M
The system must be protected via a leakage current protective device (RCD⁄ FI)
with a measurement difference current of ≤ 30 mA.
The proper function of this protective device must be checked at regular intervals.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Wear personal protective equipment (PPE) (safety shoes, gloves, etc.)
⁄ Any work may only be carried out in a de-energized state. Here, the voltage sup-
ply must be safely separated via the main switch or mains plugs.
⁄ All components must remain accessible.
⁄ Finish assembling and positioning before you connect the mains plug to the power
socket.
⁄ Do not try to exchange a damaged connection cable but have the manufacturer
replace it.
⁄ The required minimum floor load is 200 kg⁄m². The floor must be levelled properly,
i.e. it must be horizontal and even.
⁄ It is not allowed to connect displays elements firmly with building parts!
⁄ It is not allowed to restrict or block escape routes!
⁄ Protect from freezing!
⁄ After installing the fountain, a leak test must be performed.
⁄ Confirm the proper execution of the test on the respective page of the installation
instructions and send it to Hansgrohe SE.
⁄ To save electricity, Hansgrohe recommends switching off the "Fontana PowderRain"
in the evening or during longer periods of standstill.
EN