A S S E M B L Y (see page 05)
F A U L T
C A U S E
R E M E D Y
⁄ Insufficient water
⁄ Supply pressure inadequate
⁄ Check water pressure (If a pump has been installed check
to see if the pump is working).
⁄ Regulator filter dirty
⁄ Clean filter in front of the mixer and on the MTC-thermo car-
tridge
⁄ Shower filter seal dirty
⁄ Clean filter seal between shower and hose
⁄ Crossflow, hot water being forced into cold water pipe, or
vice versa, when mixer is closed
⁄ Backflow preventers dirty or leaking
⁄ Clean backflow preventers, exchange if necessary
⁄ Spout temperature does not correspond with temperature
set
⁄ Thermostat has not been adjusted
⁄ Adjust thermostat
⁄ Hot water temperature too low
⁄ Increase hot water temperature to 42 ºC to 65 ºC
⁄ Temperature regulation not possible
⁄ thermo cartridge calcified
⁄ Exchange thermo cartridge
⁄ Hot and cold supplies are reversed
⁄ change connections
⁄ Instantaneous heater didn't work with thermostat
⁄ Filters are dirty
⁄ Clean the filter ⁄ exchange filter
⁄ check valve hasn't moved back
⁄ Exchange check valves
⁄ Flow limiter in handshower isn’t removed
⁄ Remove flow limiter
⁄ Shower or spout dripping
⁄ Dirt or sedimentation on valve seat, shut-off unit damaged
⁄ Exchange shut-off unit
C L E A N I N G (see page 10)
S P E C I A L A C C E S S O R I E S (order as an extra)
tile-matching-disk #93155000 (see page 12)
S P A R E P A R T S (see page 12)
XX = Colors
00 = chrome plated
93 = Polished Brass
F L O W D I A G R A M (see page 04)
Hand shower
overhead shower
D I M E N S I O N S (see page 04)
O P E R A T I O N (see page 09)
M A I N T E N A N C E
⁄ To guarantee the smooth running of the thermostat, it is necessary from
time to time to turn the thermostat from total hot to total cold.
⁄ The mixer is equipped with check valves. The check valves must be
checked regularly according to DIN EN 1717 in accordance with
national or regional regulations (at least once a year).
A D J U S T M E N T (see page 08)
After the installation, the output temperature of the thermostat must be
checked. A correction is necessary if the temperature measured at the output
differs from the temperature set on the thermostat.
Do not use silicone containing acetic acid!
S Y M B O L D E S C R I P T I O N
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The shower system may only be used for bathing, hygienic and body cleaning
purposes.
Children as well as adults with physical, mental and⁄or sensoric impairments must
not use this product without proper supervision. Persons under the influence of
alcohol or drugs are prohibited from using this product.
Do not allow the streams of the shower touch sensitive body parts (such as your
eyes). An adequate distance must be kept between the shower and you.
The product may not be used as a holding handle. A separate handle must be
installed.
The arm of the shower head is intended only to hold the shower head. Do not load
it down with other objects!
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be oberserved.
⁄ The installation dimensions stated in these installation instructions are ideal for
people of approximately 1700 mm in body height. The dimensions can be altered
if required. In this case, pay attention to the fact that a change of installation height
will also change the minimum height, and that the altered mounting dimensions must
be taken into consideration.
⁄ During installation of the product by qualified trained personnel, make sure that the
entire fastening surface is even and smooth (no protruding seams or tile offset), that
the finish of the wall is suitable to apply the product and has no weak points.
⁄ The filter insert must be use to protect the shower against incoming dirt by
pipework. Incoming dirt leads to defects or⁄and can damage parts of the shower;
such caused faults voids all liability and guarantee claims.
⁄ The product is not designed to be used with steam baths!
EN
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Centre distance:
150 mm
Connections G 1⁄2:
cold right - hot left
Thermal disinfection:
max. 70°C ⁄ 4 min
Safety against backflow
The product is exclusively designed for drinking water!