TECHNICAL INFORMATION

Water pressure

  Recommended 

15 - 75 PSI (0.1 - 0.5 MPa)

  Maximum 

145 PSI (1 MPa)

Hot water temp. 

  Recommended 

120°-140° F (48° - 60° C)*

  Maximum  

158°F (70° C)*

Max. flow rate

  39835xx1 / 39836xx1 

1.75 GPM (6.6 L/min)

  39846xx1 

1.5 GPM (5.7 L/min)

Hole size in mounting surface 

1½" (38 mm)

Max. depth of mounting surface 

2¾" (70 mm)

*  Please know and follow all applicable local plumbing 

codes when setting the temperature on the water heater.

INSTALL ATION CONSIDERATIONS

 ⁄ For best results, Hansgrohe recommends that this unit 

be installed by a licensed, professional plumber.

 ⁄ Please read over these instructions thoroughly 

before beginning installation. Make sure that you 

have all tools and supplies needed to complete the 

installation.

 ⁄ Protection against backflow is provided by two 

check valves in the sprayhead.

 ⁄ Keep this booklet and the receipt (or other proof of 

date and place of purchase) for this product in a 

safe place. The receipt is required should it be neces-

sary to request warranty parts. 

DONNÉES TECHNIQUES 

Pression d’eau

  recommandée 

15 - 75 PSI (0.1 - 0.5 MPa)

  maximum 

145 PSI (1 MPa)

Température d'eau chaude 

  recommandée  

120°-140° F (48° - 60° C)*

  maximum 

158°F (70° C)*

Capacité nominale 

  39835xx1 / 39836xx1 

1.75 GPM (6.6 L/min)

  39846xx1 

1.5 GPM (5.7 L/min)

Dimension du trou dans 

1½ po (38 mm)

  la surface de montage

Profondeur maximale de  

2¾ po (70 mm)

  la surface de montage

*  Vous devez connaître et respecter tous les codes de plom-

berie locaux applicables pour le réglage de la température 
du chauffe-eau.  

 

À PRENDRE EN CONSIDÉRATION POUR 

L’INSTALL ATION

 ⁄ Pour de meilleurs résultats, Hansgrohe recommande 

que ce produit soit installé par un plombier profes-

sionnel licencié.

 ⁄ Veuillez lire attentivement ces instructions avant de 

procéder à l’installation. Assurez-vous de disposer 

de tous les outils et du matériel nécessaires pour 

l’installation.

 ⁄ La protection contre le retour d'eau est fournie par un 

clapet de non-retour double.

 ⁄ Conservez ce livret et le reçu (ou une autre preuve 

sur laquelle figurent la date et l’endroit de l’achat) 

pour ce produit dans un endroit sûr. Le reçu est requis 

si vous commandez des pièces sous garantie.

Содержание Citterio 39835 1 Series

Страница 1: ... O N EN Installation User Instructions Warranty FR Instructions de montage Mode d emploi Garantie ES Instrucciones de montaje Manejo Garantía AXOR Citterio HighArc 2 Spray Pull Down 39835xx1 39846xx1 AXOR Cittero Prep 2 Spray Pull Down 39836xx1 ...

Страница 2: ...ld it be neces sary to request warranty parts DONNÉES TECHNIQUES Pression d eau recommandée 15 75 PSI 0 1 0 5 MPa maximum 145 PSI 1 MPa Température d eau chaude recommandée 120 140 F 48 60 C maximum 158 F 70 C Capacité nominale 39835xx1 39836xx1 1 75 GPM 6 6 L min 39846xx1 1 5 GPM 5 7 L min Dimension du trou dans 1 po 38 mm la surface de montage Profondeur maximale de 2 po 70 mm la surface de mont...

Страница 3: ...entador de agua CONSIDERACIONES PARA LA INSTALACIÓN Para obtener mejores resultados la instalación debe estar a cargo de un plomero profesional matriculado Antes de comenzar la instalación lea estas instruc ciones detenidamente Asegúrese de tener las her ramientas y los insumos necesarios para completar la instalación La protección contra flujo inverso se proporciona mediante una válvula de retenc...

Страница 4: ... AXOR Cittero Prep 2 Spray Pull Down 39836xx1 2 7 0 m m 15 387 mm 8 224 mm 7 200 mm max 2 70 mm 5 134 mm 8 224 mm Ø2 64 mm 1 34 mm 32 835 mm 16 427 mm max 2 70 mm 5 134 mm 8 224 mm 9 246 mm Ø2 64 mm 8 220 mm 1 34 mm 32 835 mm a p p r o x 1 7 4 5 0 m m 5 137 mm ...

Страница 5: ...5 OPTION AL ADJUST THE SPOUT ROTATION AJUSTEZ L A ROTATION DU BEC AJ USTE L A ROTACIÓN DEL SURTIDOR 39835XX1 398 46XX1 1 2a 24 x 15 39835xx1 1 2 39846xx1 ...

Страница 6: ...6 39835xx1 39846xx1 3 1 2 3 2b 24 x 15 ...

Страница 7: ...taje Instale la arandela plástica la arandela de fibra la arandela de fricción y la tuerca de fijación Si el espesor de la mesada es superior a 1 pulg 35mm o si no hay suficiente espacio puede omitirse la arandela plástica Place the faucet and sealing ring on the mounting surface Install the plastic washer friction washer metal washer and mounting nut If the mounting surface is thicker than 1 35mm...

Страница 8: ...e suministro 1 Abra la conexión rápida empujándola hacia arriba 2 Inserte la manguera de rociador de mano en la conexión rápida 3 Trabe la conexión rápida tirando hacia abajo Install the hose weight Test the handspray hose If it does not retract smoothly reposition the weight 3 from the bottom of the hose Installez le contrepoids sur le tuyau Tirez sur le gicleur Elle devrait coulisser facilement ...

Страница 9: ... fermement a l aide de deux clés ASSUREZ VOUS QUE LES TUYAUX N SENTORTILLENT PAS Conecte las mangueras de suministro de agua caliente y fría a las alimentaciones de la red Use dos llaves como se illustra en el diagrama NO PERMITA QUE NINGUNA DE LOS MANGUERAS SE RETUERZA Remove the sprayhead Remove the filter Retirez le douchette Retirez le filtre Retire la ducha Retire el filtro 9 mm 16 mm 5 6 1 2...

Страница 10: ...ll the filter in the handspray hose Lightly lubricate the hose o ring Install the handspray Tighten the hose nut Installez le filtre dans le tuyau flexible Lubrifiez le joint torique du tuyau Installez le douchette Serrez l écrou Instale el filtro en la manguera Lubrique ligeramente la junta tórica de la manguera Instale la ducha Apriete la tuerca de la manguera 2 min 7 8 1 2 3 4 ...

Страница 11: ...TOP RÉGL AGE DE L A BUTÉE LIMITE D EAU CHAUDE AJUSTE EL TOPE DE LÍMITE DE ALTA TEMPERATURA 140 F 60 C 50 F 10 C 44 PSI 0 3 MPa 1 91 F 33 C 97 F 36 C 100 F 38 C 109 F 43 C 122 F 50 C 131 F 55 C 140 F 60 C 3 mm 4x 3 mm 1 2 3 4 5 6 1 2 1 2 ...

Страница 12: ...39846xx1 88624000 98551000 92634000 40x3 98211000 21x2 5 98231000 18x1 5 98140000 20x1 96762000 96029000 97735000 97209000 95049000 96316001 95561000 92115000 37x2 92730000 97350000 97523000 97548000 150 110 39891xx0 98603xx0 98127000 11x2 98365000 98365000 95909000 95910000 95340000 39835xx1 39836xx1 95376000 39846xx1 95908xx1 39853xx1 39836xx1 93252xx1 39846xx1 AXOR Citterio 39836xx1 95008000 ...

Страница 13: ...13 USER INSTRUCTIONS INSTRUCTIONS DE SERVICE MANEJO off fermé cerrar on ouvert abierto cold froid frío hot chaud caliente 1 2 ...

Страница 14: ...14 C L E A N I N G N E T T O YA G E L I M P I E Z A 4 5 6 1 2 3 1 2 ...

Страница 15: ...15 7 8 1 2 3 ...

Страница 16: ...m faucets kitchen faucets and shower products are made from different materials to comply with the needs of the market with regard to design and functionality To avoid damage to the product it is necessary to take proper care of it FOR BEST RESULTS Prevent the buildup of mineral scale and or soap residue by cleaning your Hansgrohe product s when needed Select a cleaning agent specifically intended...

Страница 17: ...nar tambien los materiales Enjuague el producto con agua limpia después de cada uso Los residuos de limpiadores para lavatorios bañeras o azulejos pueden causar daño a los grifos y accesorios Enjuague inmediatamente cualquier derrame que haya sobre el producto de Hansgrohe Tampoco pueden generarse depositos de productos de limpieza o quimicos debajo de los productos p ej En un armario de lavabo De...

Страница 18: ...use including use of the product for an unintended application freezing water excessive water pressure pipe corrosion in the home in which the product is installed abuse neglect or improper or incorrectly performed instal lation maintenance or repair including the use of abrasive or caustic cleaning agents or no rinse cleaning products This warranty does not cover i accessories connected materials...

Страница 19: ...egal rights and you may also have other rights which vary from state to state PRODUCT INSTRUCTIONS AND QUESTIONS Upon purchase or prior to installation please carefully inspect your prod uct for any damage or visible defect Prior to installing always carefully study the enclosed instructions on the proper installation and the care and maintenance of this product If you have questions at any time a...

Страница 20: ...AXOR Hansgrohe Inc 1490 Bluegrass Lakes Parkway Alpharetta GA 30004 Tel 800 334 0455 Fax 770 889 1783 axor design com US Installation Instructions Part No 90588732 Revised 05 2022 ...

Отзывы: