10
5
Settings Menu
Introduction
The settings menu displays the current state of each setting within
the SAM08 and enables the item to be changed or adjusted.
Settings can be changed using the front panel of the Synapse
frame (SFR18 or SFR04) or Synapse Setup software.
Please refer to chapter 3 for information on the Synapse front
panel control and Synapse Setup software.
Output
The setting menu item
Output
selects the format of the video
signal at the outputs of the SAM08. Output can be set to
VideoAll
selecting a composite video signal on the video
outputs, or
YC
that selects separated Y (luminance) and C
(Chrominance).
The default setting is
VideoAll
.
Standard
This item determines the input video standard and the setting of
the internal colorbar generator.
Standard
can be set to
Auto
,
NTSC
,
PAL-BDGHI
,
iCB75_525
,
iCB75_625
. The settings
iCB75_525
&
iCB75_625
select the internal colorbar
generator.
The default setting is
Auto
.
Y-Filter
Y-Filter
allows the selection of filters with different
characteristics that can be used to enhance Luminance
performance.
Y-Filter
can be set to
Normal
,
Low-Pass
and
Notch
.
The default setting is
Normal
.
C-Filter
The
C-Filter
setting adjusts the bandwidth of the chroma
channel. Selection is made between
LP1.3
,
LP.65
,
LP1.0
, and
LP2.0
all of which represent the bandwidth in MHz.
The default setting is
LP1.3
.
Setup
Setup
allows the user to add setup when using NTSC signals.
The settings of
Setup
are
Enabled
&
Disabled
.
The default setting is
Disabled
.
EDH-Det
This setting allows the user to choose between Active-Picture
(
Active-P
) or Full-Field (
Full-F
) EDH detection.
Содержание Synapse SAM08