10 

 

3.

 

Reprogramming the panel 

 

 

The firmware on the hardware panel can be reprogrammed via an Ethernet 
connection by using a web page available when the unit is in its bootloader 
mode. 
 
To put the panel into its bootloader mode, first power the unit on and make a 
note of the current IP address setting making sure this address is available from 
the PC you will use to reprogram the panel. Then press buttons 1, 3, 19 and 21 
at the same for five seconds or more. 
 
The panel will then display a menu with the default and bootloader options. 
 

 

Press button 10 saying YES to the right of EXIT TO BOOT LOADER. 
 
The unit after a short while will then show a single illuminated button saying 
BOOT LOADER. 
 
When the panel is in this mode, it will host a webserver at its IP address. If you 
use a web browser and type in the IP address in the address bar it will display 
the following page: 
 

 

 
To upgrade the firmware supply the user name (‘axon’) and the password 
(‘cortex’) and press the Login button. 
 
The browser page will then prompt for a firmware file with the Browse button. 

Содержание Cerebrum CCP-4200B

Страница 1: ...CCP 4200B Cerebrum 42 LCD button control panel Operation manual ...

Страница 2: ...Hercules 28 NL 5126 RK Gilze The Netherlands Phone 31 161 850 450 Fax 31 161 850 499 E mail Info axon tv Web www axon tv OPERATION MANUAL CCP 4200B ...

Страница 3: ...on warrants their products according to the warranty policy as described in the general terms That means that Axon Digital Design BV can only warrant the products as long as the serial numbers are not removed Copyright 2001 2016 AXON Digital Design B V Date created 31 05 2016 Date last revised 31 05 2016 Axon the Axon logo and Synapse are trademarks of Axon Digital Design B V This product complies...

Страница 4: ...ents Table of Contents 4 1 Introduction 5 2 Configuration 6 Panel Configuration 6 Adding the panel to Cerebrum 7 Configuring functionality on the panel 8 GPI Contacts 8 3 Reprogramming the panel 10 4 Specifications 12 ...

Страница 5: ...entiation of functionality selection or state Eight GPI inputs are available and can be used for any function within Cerebrum but most commonly are used for selection of router sources when driven from Camera Operator Control Panel touchdowns The panel communicates with Cerebrum using a TCP IP protocol over a local or wide area Ethernet network and can be configured to use either DHCP or a manuall...

Страница 6: ...e highlighted and then using the buttons marked with the up and down arrows until the required digit is shown Each digit can be set until the required IP address is configured pressing the button showing OK will save this setting and return you to the configuration mode menu again The settings for the Subnet mask and gateway can be configured in the same way The IP Address mode can either be confi...

Страница 7: ...what the panel will show when the system starts or the panel is modified The default settings that the panels will use for the router category and view variables when restarting can be optionally defined for the panel In this way multiple panels can use the same CPF file but change their behaviour based on this information The check box for redundant PSU will make sure an alarm or warning is gener...

Страница 8: ...l provides eight GPI inputs which can be used for different functionality within Cerebrum The GPI s will show themselves in the Tally and Joystick dialogs of the Cerebrum configuration provided the panel is given a device name when adding it to the system The GPI inputs are internally fed to an optical isolator which provides an electrical isolation between the input signals applied to the unit Th...

Страница 9: ...Where pin 10 is the pin on the furthest left hand side as you view the rear of the unit The pin out of the connector is also shown on a label on the rear of the unit Serial Port The use of the RS 422 Serial port is not currently supported at the moment It will be available in future releases ...

Страница 10: ...the same for five seconds or more The panel will then display a menu with the default and bootloader options Press button 10 saying YES to the right of EXIT TO BOOT LOADER The unit after a short while will then show a single illuminated button saying BOOT LOADER When the panel is in this mode it will host a webserver at its IP address If you use a web browser and type in the IP address in the addr...

Страница 11: ...load button the panel will then reprogram itself After successfully programming the unit it will then prompt the user to reset the MCU After doing this the brower will complete and the unit will reset itself and show the normal starting UI as described above ...

Страница 12: ... 71 Depth excluding front panel including DC connector 65mm 2 55 Weight Weight including power adapter CCP 4200B 1 5kg Power AC PSU Panel input 100 240V AC 1 0A 0 5A Frequency 50 60 Hz 12V DC 4 0A General Purpose Inputs Typical input current 6 4mA Miscellaneous Operating environmental temperature 0º to 40º C 32º to 104º F Storage environmental temperature 20º to 70º C 4º to 158º F ...

Отзывы: