Axnes AS
Document number
Revision
Date
AX-PNG-UMAN-1220
Issue C
2018-Jun-05
Page 4-1
Confidential document and information
Section 4:
Technical data
Technical data for MP50
4.1.1 Operation
Radio:
UHF Duplex, single frequency
VHF Maritime band
VOX operation:
Axnes AS patented NIVOX, ensures no loss and
operation in high noise environment
Number of wireless users:
Unlimited
Number of groups:
2
Number of radio configurations: 52 intercom configurations, 50 VHF channels
Encryption:
AXS-SW-0221 using AES-256
Operating temperature:
-20°C to +55°C with internal battery.
-40°C to +55°C with external battery
Charging temperature:
MP50:
0°C to +50°C
MP50M:
5°C to +45°C
Storage temp. (survival):
-40°C to +60°C
Storage temp. (recommended):
+10°C to +35°C
Water resistance:
EN 60629 IP68, 3 meters depth for 30 minutes
Altitude:
25000 feet
NVG:
Optional NVIS class B friendly
AIS SART MMSI:
97071xxxx, where xxxx is the 4 last digits of the device
serial number, Note 2
4.1.2 Power supply
Supply:
MP50
: Internal rechargeable Li-Ion 3.6V 4700mA battery
MP50M
: Internal rechargeable NiMh 3.6V 1600mA
External battery option: 5
–15V
Operating time (typ):
MP50:
Standby: 30 hours
Transmit: 7 hours
Receive: 12 hours
MP50M:
Standby: 11 hours
Transmit: 2.5 hours
Receive: 4.5 hours
Note:
Actual use time will be affected by battery
temperature.
Charging time (typ):
MP50:
3 hours
MP50M:
2 hours
Longer charge time may be expected at high and low
temperatures.