Maintenance
12
The router elevator requires minimum maintenance, but you are advised to observe the following points:-
1. Keep the elevator clean. Ensure that dust/chips etc., are cleaned away at the end of a work session.
2. Do not allow a build up of dust/chips etc., between the machine table and the rise and fall platform, or under
the machine, where it may foul the chain drive.
3. If the winding action becomes ‘lumpy’ check that there is no debris caught in the chain, or compressed onto a
sprocket.
4. Check the chain tension. If the chain has become ‘slack’ or loosened, re-tension by adjusting the idler sprocket.
Do not over tension, the chain needs to be firm, with a small side to side movement (best checked on a ‘long’ side)
it does not need to be rigid. (See Figs 5 and 6)
5. Remember! A chain is a machine as well, give it a light lube.
idler sprocket
Loosen the idler sprocket bolt, using a 6mm Hex key
and adjust the sprocket until the chain is firm
Fig 5
Fig 6