SETTING THE BAR TO THE PLATEN
16
Using a digital leveling box check the suport bar is perpendicular
to the platen. Place the leveling box onto the bar, it should read
‘ZERO’ on the display. If adjustment is required, lightly loosen the
four Hex screws and adjust the support bar until the ‘Bar’ is in line
with the platen, nip up the Hex screws to secure the assembly.
The ‘Angle Gauge’ tool is a quick and easy way to accurately set
the correct clearence between the platen and the support bar.
The gauge has five preset stops from 20˚ to 40˚ degrees.
The gauge also incorporates a 25mm projection stop to set the
correct projection of the chisel out from the ‘Honing Guide’
assembly.
Linisher
Bar
Setting the Bar at 90˚ to the Platen
Hex screw
Alternatively place a 90˚ square on the bar and check its in line
with the edge of the platen and make adjustments accordantly.
Gap
Square to the platen
Gap
Method One
Method Two
Ultimate Edge Angle Gauge