background image

5

Keep the particle filter clean. The machine relies on its 
ability to ‘blow’ air through the filter, to generate good 
suction. If the particle filter starts to clog, this reduces the 
air flow and hence the machine becomes less efficient. 

The particle filter can be cleaned, by removing the rear 
filter cover (20) and using a vacuum cleaner, clean the 
inside of the filter as illustrated on page 17. 

Be aware that in dry air periods or areas, the movement 
of the air through the machine can generate static 
electric fields. These are not normally a problem as the 
machine is bonded together via its construction and 
the whole is earthed back through the electrical supply; 
problems can occur with isolated items, such as stands 

or hosing that are insulated from the ground (standing 
on rubber feet?, suspended in the air etc).

If possible, try to connect everything together electrically, 
to eliminate static shocks.

(Use the integral metal coil in flexible plastic hosing to 
connect units together).

Try to route the power cable and the hosing away from 
busy walkways.
 

Do not

 allow the inlet to become ‘dead ended’, or block 

or restrict the outlet, this puts undue strain on the motor 
and can lead to overheating.

Code 

107622  107623 107624

Model 

AP154CEH 1.5HP 

AP176CEH 2HP  

AP357CEH 3HP

Rating 

Professional  Professional Professional

Power 

1.1 kW 1Phase 

1.5 kW 1Phase 

2.2 kW 1Phase

Supply Circuit 

16 Amps (Type C Breaker) 

16 Amps (Type C Breaker) 

16 Amps (Type C Breaker)

Air Flow 

1,600 m³/hr @ 150 mm 

1,715 m³/hr @ 178 mm 

3,700 m³/hr @ 200 mm

Sound Pressure  
Level [Uncertainty K] 

76 dB(A)  

76 dB(A)  

77 dB(A)

Static Pressure 

2,440 Pa  

2,490 Pa  

2,735 Pa

Filter Performance 

99.97% >0.3 micron 

99.97% >0.3 micron 

99.97% >0.3 micron

Filter Surface Area 

2.5 m² 

2.5 m² 

4.35 m²

Container Volume 

110 litre 

168 litre 

198 litre

Inlet 

1 x 150 mm or 2 x 100 mm  

1 x 178 mm or 3 x 100 mm   1 x 200 mm or 3 x 100 mm

Overall L x W x H 

1,120 x 700 x 1,780mm 

1,120 x 700 x 2,080mm 

1,370 x 790 x 2,030mm

Weight 

117kg  127kg 155kg

SPECIFICATION

ASSEMBLY INSTRUCTIONS

Please read through the section entitled Parts identification and Description, this will enable you to more readily
identify those parts of the cyclone extractor.

  

Please note: some of this assembly procedure is best accomplished by two persons. Although    

 

  the tasks are not impossible, some of the items are heavy and awkward, and a mishandling  

 

 

  error could cause injury. Please think about what you are doing, your capabilities and your  

 

 

  personal safety. We have added the ‘two person symbol’ to any operation that we recommend    

 

  should be a two person task.

Unpack all the boxes and check all the components listed in the “What’s Included” section. If any parts or components 
are missing, please contact our Customer Services Department using the procedures and telephone numbers listed 
in our catalogue. 
 

Please note: on occasions the packing list is not strictly adhered to. Please check all the boxes, packets
etc. to make sure that all the parts have been accounted for.

PLEASE RECYCLE ANY UNWANTED PACKAGING RESPONSIBLY!

SPECIFIC SAFETY FOR DUST EXTRACTORS

Содержание 107622

Страница 1: ...022 BOOK VERSION 8 AP154CEH AP176CEH AP357CEH Cyclone Extractors AP154CEH Code 107622 AP176CEH Code 107623 AP357CEH Code 107624 Original Instructions Code 107622 AP154CEH Code 107624 AP357CEH Code 107623 AP176CEH ...

Страница 2: ...for which the EC Type Examination Certificate No 3X181109 FTQD79 has been issued by FUSSOTOOL CORP at No 679 Sec 4 Changping Rd Daya Dist Taichung City 428 Taiwan R O C and complies with the relevant essential health and safety requirements 2006 42 EC 2014 42 EU EN ISO 12100 2010 EN ISO 4414 2010 declares that the machinery described This machine complies with the following directives EU Declarati...

Страница 3: ...uction Manual prior to using your new machine As well as the operating procedures for your new machine there are numerous hints and tips to help you to use the machine safely and to maintain its efficiency and prolong its life There is also a detailed description of the parts of your Cyclone Extractor which will enable you to become familiar with terminology we will use in this manual Keep this In...

Страница 4: ...it could be tripped over as you move about the workshop it is not too close to an unguarded heat source or is laid over or around a sharp edge If the work you are carrying out is liable to generate flying grit dust or chips wear the appropriate safety clothing goggles gloves masks etc If the work operation appears to be excessively noisy wear ear defenders If you wear your hair in a long style wea...

Страница 5: ...ker 16 Amps Type C Breaker Air Flow 1 600 m hr 150 mm 1 715 m hr 178 mm 3 700 m hr 200 mm Sound Pressure Level Uncertainty K 76 dB A 76 dB A 77 dB A Static Pressure 2 440 Pa 2 490 Pa 2 735 Pa Filter Performance 99 97 0 3 micron 99 97 0 3 micron 99 97 0 3 micron Filter Surface Area 2 5 m 2 5 m 4 35 m Container Volume 110 litre 168 litre 198 litre Inlet 1 x 150 mm or 2 x 100 mm 1 x 178 mm or 3 x 100...

Страница 6: ... 05 Figure 05 Figure 06 Remove the remaining items from the waste bin The waste bin fits into a recess in the base plate so with the large handle lowered place the bin against the two rubber stoppers Figure 06 and raise the handle Figure 07 Unpack the switch there should be a small pack containing two small machine screws with nuts and the remote control fob The switch is mounted with the two mach...

Страница 7: ...ance The AP357CEH is fitted with electric filter cleaning which operates when the machine is switched off The filter has a very long life and barring damage even when partially clogged can be cleaned from the inside with an M Class vacuum cleaner Never use a high pressure blow gun from the outside to disturb dust that may be attached to the inside surface The golden rule with filter cleaning is li...

Страница 8: ...E CONTROL The manometer is used to monitor the air flow in the ducting system When you first use your extractor it is recommended you mark on manometer the pressure the extractor it running at to do this follow the instructions below Note the reading can vary depending on the size of the ducting system 1 Connect your cyclone extractor to the ducting system Figure 01 2 Start up the extractor by pre...

Страница 9: ...ce Basic Maintenance WARNING always wear a dust mask WARNING Always wear eye protection Why should I bother with LEV The law says you must control the risks from these substances the Control of Substances Hazardous to Health COSHH Regulations Installing LEV may help you to do this For more information about other ways of eliminating or reducing airborne contamination at work look at HSE s COSHH we...

Страница 10: ...olt 5 16 x 1 2 36 38 Bearing Fixing Plate Thread 2 39 Connecting Spindle 1 40 Hex Bolt M6 x 16L 1 No Description Qty 41 Main Spindle 1 42 Lower Bracket 1 43 Whasher 1 4 7 44 Philp HD Screw M6 10 1 45 Philp HD Screw M5 8 3 46 Lower Bracket Fixing Plate 2 47 Philp HD Screw M5 x 15 4 48 Nut M5 4 49 Magnetic Switch with remote receiver 1 50 Dust bag Small 1 51 Belt Clamp 1 52 Inlet Cap 4 1 53 Philp HD...

Страница 11: ...11 EXPLODED DIAGRAMS LISTS AP154CEH 1 5HP Model 88150T ...

Страница 12: ...ange Bolt 5 16 x 1 2 36 38 Bearing Fixing Plate Thread 2 39 Connecting Spindle 1 40 Hex Bolt M6 x 16L 1 No Description Qty 41 Main Spindle 1 42 Lower Bracket 1 43 Whasher 1 4 7 44 Philp HD Screw M6 10 1 45 Philp HD Screw M5 8 3 46 Lower Bracket Fixing Plate 2 47 Philp HD Screw M5 x 15 4 48 Nut M5 4 49 Magnetic Switch with remote receiver 1 50 Dust bag Small 1 51 Belt Clamp 1 52 Inlet Cap 4 1 53 Ph...

Страница 13: ...13 EXPLODED DIAGRAMS LISTS AP176CEH 2HP Model 88200T ...

Страница 14: ...ge Screw 5 16 x 1 2 30 38 Sliding Block 2 39 Spring 2 40 Copper Plate 4 No Description Qty 41 Copper Plate 4 42 Special Washer 2 43 Lever Handle 1 44 Connecting Plate 2 45 Plastic Washer 4 46 Lock Nut 5 16 6 47 Washer 5 16 4 48 Hex Bolt 5 16 x 1 1 2 2 51 Hex Bolt 5 16 x 1 2 52 Philp HD Screw 3 16 x 3 8 1 53 Magnetic Switch with Receiver 1 54 Power Cord 1 55 Reducer 1 56 Small Motor 1 57 Cap Screw ...

Страница 15: ...15 EXPLODED DIAGRAMS LISTS AP357CEH 3HP Model 88300TA ...

Страница 16: ...ears For more information visit axminstertools com 3years Axminster Tools Axminster Devon EX13 5PH axminstertools com The packaging is suitable for recycling Please dispose of it in a responsible manner Do not dispose of electric tools together with household waste material By law they must be collected and recycled separately EU Countries Only ...

Отзывы: