AXIS T85 PoE+ Network Switch Series
Setup examples
-
If you want to use the same schedule for all days of the week, select the start and end times on the
Week Day
row marked with an asterisk (
*
).
-
If you want to use the same schedule for certain days of the week only, select the start and end times for
selected days on the respective
Week Day
rows.
6. Click
Apply
.
To assign the created PoE schedule to one or more PoE ports:
1. Go to
Basic > Basic Settings > PoE > Power Management
.
2. Under
PoE Port Configuration
in the
PoE Schedule
drop-down menu, select the number of the specified PoE schedule
profile.
-
If you want to assign the same profile for all ports, select the profile number on the
Port
row marked with an
asterisk (
*
).
-
If you want to assign the same profile for certain ports only, select the profile numbers for selected ports on the
respective
Port
number rows.
3. Click
Apply
.
Check connection status via PoE auto checking
You can use PoE auto checking if you want to periodically check the connection status between your switch and the PoE enabled
network device connected to it. If, during auto checking, the network device does not respond to the switch, the switch will
automatically restart the PoE port the network device is connected to.
To enable auto checking via the topology view:
1. Go to
Basic > Topology View
.
2. To open the
Dashboard
console of your switch, click the switch icon.
3. Click
PoE Config
.
4. In the
PoE Auto Checking
drop-down menu, select
Enable
.
To configure the auto checking parameters:
1. Go to
Advanced > PoE > Configuration > Auto Checking
.
2. In the
Ping IP Address
field, enter the IP address of the device that is connected to the port you want to assign auto
checking for.
3. Enter the other needed parameters, for example:
-
Port
: 1
-
Ping IP Address
: 192.168.0.90
-
Startup Time
: 60
-
Interval Time (sec)
: 30
-
Retry Time
: 3
-
Failure Action
:
Reboot Remote PD
-
Reboot time (sec)
: 15
4. Click
Apply
.
13