Axis T85 Скачать руководство пользователя страница 12

AXIS T85 PoE+ Network Switch Series

Setup examples

2. Under

Basic Settings

in the

Protocol Version

drop-down menu, select

RSTP

, and click

Apply

.

3. Go to

Advanced > Spanning Tree > Configuration > CIST Port

.

4. Under

CIST Normal Port Configuration

, make sure that

STP Enabled

is selected for the switch’s ports as follows:

-

Switch – 01: ports 25 and 26

-

Switch – 02: ports 17 and 18

-

Switch – 03: ports 9 and 10

5. Click

Apply

.

Note

If you want to make sure that a certain port is used as a primary communication link, enter

Path Cost

for that port under

CIST Normal Port Configuration

. If not specified, the switch chooses the port automatically. For example, if you want to use

port 17 as the primary communication link, enter

Path Cost

value 10 to port 25 and

Path Cost

value 50 to port 18.

To save the start-up configuration, click

on the product’s web page. See

Get to know your product’s web page on page 9

.

Reserve an IP address based on MAC address

1. Go to

Advanced > DHCP Server > Configuration > Pool

.

2. Click

Add New Pool

.

3. Enter a name for the pool, for example 00:01:02:03:04:05, and click

Apply

. No spaces are allowed in the name.

4. To access the pool settings, click the added name.

5. In the

Type

drop-down menu, select

Host

.

6. Enter other required settings, such as

IP

address,

Subnet Mask

and

Default Router

.

7. In the

Client Identifier

drop-down menu, select

MAC

.

8. In the

Hardware Address

field, enter F8-16-54-B2-35-63.

9. Click

Apply

.

To save the start-up configuration, click

on the product’s web page. See

Get to know your product’s web page on page 9

.

Set a PoE schedule

If you have a certain time frame where you want the switch to provide PoE, for example, to your cameras, it can be useful to create a
PoE schedule and assign it to one or more PoE ports. You can create up to 16 PoE schedule profiles.

To create a PoE schedule:

1. Go to

Advanced > PoE > Configuration > Schedule Profile

.

2. In the

Profile

drop-down menu, select a number for the profile.

3. Change the default profile name as needed.

4. To specify when you want PoE to switch on, select hours (

HH

) and minutes (

MM

) in the

Start Time

drop-down menu.

5. To specify when you want PoE to switch off, select hours (

HH

) and minutes (

MM

) in the

End Time

drop-down menu.

12

Содержание T85

Страница 1: ...AXIS T85 PoE Network Switch Series AXIS T8504 R Industrial PoE Switch AXIS T8508 PoE Network Switch AXIS T8516 PoE Network Switch AXIS T8524 PoE Network Switch User Manual ...

Страница 2: ...Set up access VLANs 11 Create redundant links between switches for network redundancy 11 Reserve an IP address based on MAC address 12 Set a PoE schedule 12 Check connection status via PoE auto checking 13 How to connect a 60 W camera AXIS T8504 R 14 How to use the console port AXIS T8504 R 14 Maintenance 15 Restart the product 15 Set a reboot schedule 15 Restore the product to factory default val...

Страница 3: ...he Internet Protocol IP and Simple Network Management Protocol SNMP is assumed This User Manual provides information mainly on how to access the product access connected IP devices in the product s topology view configure selected setup examples perform maintenance on the product Product features and their settings are covered in more detail in the product s context sensitive built in help For mor...

Страница 4: ...AXIS T85 PoE Network Switch Series Solution overview Solution overview 4 ...

Страница 5: ...4 R Industrial PoE Switch 1 Product label 2 RJ45 ports PoE x4 3 RJ45 ports Uplink x2 4 SFP slots x2 5 LEDs front panel 6 Power connector x2 7 Digital input 8 Digital output relay 9 Console connector 10 DIP switch 11 Reset button 12 Grounding screw AXIS T8508 PoE Network Switch 5 ...

Страница 6: ... reset button 3 RJ45 ports PoE x8 4 RJ45 ports non PoE x2 5 SFP slots x2 6 Power connector 7 Product label AXIS T8516 PoE Network Switch 1 Bracket 2 LEDs front panel 3 Mode reset button 4 RJ45 PoE ports 1 16 5 RJ45 port 17 18 6 SFP slot 17 18 7 Power connector 8 Product label 6 ...

Страница 7: ... Network Switch Series Product overview AXIS T8524 PoE Network Switch 1 Bracket 2 LEDs front panel 3 Mode reset button 4 RJ45 ports PoE x24 5 RJ45 ports non PoE x2 6 SFP slots x2 7 Power connector 8 Product label 7 ...

Страница 8: ...o discover and assign an IP address go to axis com support 2 Enter the username and password provided on the product label 3 Follow the steps in the setup wizard to Change the password recommended for security reasons Set the IP address via DHCP or manually Configure the DHCP server Set the date time information Set the system information 4 Click Apply 5 Relogin using the new password You will now...

Страница 9: ...eatures 8 Save button save the start up configuration 9 Help button access the context sensitive built in help 10 Log out button 11 Menu path Get to know your product s built in help Your product has a context sensitive built in help The help provides more detailed information on the product s basic and advanced features and their settings To access the help content for any given view click Some h...

Страница 10: ...2 Zoom in and zoom out buttons 3 Drop down button to access and change device information to be displayed in the view 4 Content area for devices discovered in the network 5 Settings button to access and change device group and configuration information When you click a device icon in the topology view a device console is opened to allow you access to dashboard console with device information and a...

Страница 11: ...1 10 11 12 13 200 and 300 3 To assign a created VLAN ID to a given port under Port VLAN Configuration enter the ID to the Port VLAN field 4 Click Apply Create redundant links between switches for network redundancy If network redundancy is required you can create redundant links between switches using spanning tree configuration In this example there are 3 switches connected by a redundant link an...

Страница 12: ...ew Pool 3 Enter a name for the pool for example 00 01 02 03 04 05 and click Apply No spaces are allowed in the name 4 To access the pool settings click the added name 5 In the Type drop down menu select Host 6 Enter other required settings such as IP address Subnet Mask and Default Router 7 In the Client Identifier drop down menu select MAC 8 In the Hardware Address field enter F8 16 54 B2 35 63 9...

Страница 13: ...t number rows 3 Click Apply Check connection status via PoE auto checking You can use PoE auto checking if you want to periodically check the connection status between your switch and the PoE enabled network device connected to it If during auto checking the network device does not respond to the switch the switch will automatically restart the PoE port the network device is connected to To enable...

Страница 14: ...for certain ports only select the mode for selected ports on the respective Port number rows 3 Click Apply How to use the console port AXIS T8504 R The switch has a serial console port that allows you to manage the switch through the command line interface 1 Connect the supplied console cable to the console connector on the switch 2 Connect the console cable to the COM port on your computer 3 On y...

Страница 15: ... Apply Restore the product to factory default values Important Any configuration files or scripts you have saved in the product are restored to factory default values 1 Go to Advanced Maintenance Factory Defaults 2 If you want to keep the current IP settings select Keep IP setup 3 Click Yes Note For more information on how to restore the product to factory default values using the mode reset butto...

Страница 16: ...ve image is already set as the alternate image only the Active Image table is shown and the Activate Alternate Image button is disabled If the alternate image is already set as the active image either manually or due to corrupted primary image and a new firmware image is uploaded to the product the new image will automatically be set as the active image Firmware version and date information may be...

Страница 17: ...form the following tasks Task to be performed Time period of pressing Mode Reset button LED Port status LED behavior Change port status mode between Link Act Speed and PoE 0 2 seconds Green lit LED status changes according to the selected mode Reset the product 2 7 seconds Green blink The lights are OFF for all LEDs Restore to the original factory default settings 7 12 seconds Green blink The ligh...

Страница 18: ...h Amber blink Error There is no corresponding rapid chain switch found RC N A Rapid chain disabled Port status LEDs LED Color Indication Green lit The port is enabled and established a link to connected device and the connection speed is 1000Mbps Green blink The port is transmitting receiving packets and the connection speed is 1000Mbps Amber lit The port is enabled and established a link to conne...

Страница 19: ...ansmitting receiving packets and the connection speed is 100Mbps SFP ports N A The port has no active network cable connected or it is not established a link to connected device Otherwise the port may have been disabled through the product user interface AXIS T8508 AXIS T8516 AXIS T8524 System LED LED Color Indication Green lit The switch is powered ON N A The switch is not receiving power System ...

Страница 20: ...ort may have been disabled through the product user interface Green lit The port is enabled and established a link to connected device and the connection speed is 1000Mbps Green blink The port is transmitting receiving packets and the connection speed is 1000Mbps Amber lit The port is enabled and established a link to connected device and the connection speed is 100Mbps Amber blink The port is tra...

Страница 21: ...User Manual Ver M5 3 AXIS T85 PoE Network Switch Series Date May 2021 Axis Communications AB 2017 2021 Part No T10114339 ...

Отзывы: