AXIS Q60 Series
I/O terminal connector -
Use with external devices in combination with, for example, tampering
alarms, motion detection, event triggering, time lapse recording and alarm notifications. In addition
to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
•
Digital output — For connecting external devices such as relays and LEDs.
Connected devices can be activated by the VAPIX® Application Programming
Interface, output buttons on the Live View page or by an Action Rule. The output
will show as active (shown under
System Options > Port & Devices > Port
Status
) if the alarm device is activated.
•
Digital input — An alarm input for connecting devices that can toggle between
an open and closed circuit, for example: PIRs, door/window contacts, glass
break detectors, etc. When a signal is received the state changes and the input
becomes active (shown under
System Options > Port & Devices > Port Status
).
I/O connector
DC power input
AC power input
Function
Pin
Notes
Specifications
0 V DC (-)
1
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power
out.
3.3 V DC
Max load =
250 mA
Digital input – Connect to pin 1 to
activate, or leave floating (unconnected)
to deactivate.
0 to max 40 V DC
Configurable
(Input or
Output)
3–6
Digital output – Connected to pin 1 when
activated, floating (unconnected) when
deactivated. If used with an inductive
load, e.g. a relay, a diode must be
connected in parallel with the load, for
protection against voltage transients.
0 to max 40 V DC,
open drain,
100 mA
25
Содержание Q6052
Страница 4: ......
Страница 8: ...8 ...
Страница 26: ...AXIS Q60 Series 1 0 V DC 2 DC output 3 3 V max 250 mA A I O configured as input B I O configured as output 26 ...
Страница 32: ...32 ...
Страница 52: ...52 ...
Страница 56: ...56 ...
Страница 76: ...76 ...
Страница 80: ...80 ...
Страница 100: ...100 ...
Страница 104: ...104 ...
Страница 128: ...128 ...
Страница 148: ...148 ...
Страница 169: ...169 ...
Страница 170: ...Installation Guide Ver M3 2 AXIS Q60 Series Date April 2017 Axis Communications AB 2016 2017 Part No 1718975 ...