background image

AXIS Q604 Series

Safety Instructions

WARNING

• The Axis product shall be installed by a trained professional.

NO

NO

NOTICE

TICE

TICE

• The Axis product shall be used in compliance with local laws and regulations.

• Store the Axis product in a dry and ventilated environment.

• Avoid exposing the Axis product to shocks or heavy pressure.

• Do not install the product on unstable brackets, surfaces or walls.

• Use only applicable tools when installing the Axis product. Excessive force could cause

damage to the product.

• Do not use chemicals, caustic agents, or aerosol cleaners. Use a clean cloth dampened

with pure water for cleaning.

• Use only accessories that comply with technical specification of the product. These can be

provided by Axis or a third party.

• Use only spare parts provided by or recommended by Axis.

• Do not attempt to repair the product by yourself. Contact Axis support or your Axis

reseller for service matters.

Transportation

NO

NO

NOTICE

TICE

TICE

• Keep the protective packaging. When transporting the Axis product, the protective

packaging shall be replaced in its original position.

• When transporting the Axis product, use the original packaging or equivalent to prevent

damage to the product.

Battery

The Axis product uses a 3.0 V BR/CR2032 lithium battery as the power supply for its internal
real-time clock (RTC). Under normal conditions this battery will last for a minimum of five years.

Low battery power affects the operation of the RTC, causing it to reset at every power-up. When
the battery needs replacing, a log message will appear in the product’s server report. For more
information about the server report, see the product´s setup pages or contact Axis support.

The battery should not be replaced unless required, but if the battery does need replacing, contact
Axis support at

www.axis.com/techsup

for assistance.

6

Содержание Q6042-C

Страница 1: ...AXIS Q604 Series AXIS Q6042 C PTZ Dome Network Camera AXIS Q6044 C PTZ Dome Network Camera AXIS Q6045 C PTZ Dome Network Camera ENGLISH Installation Guide ...

Страница 2: ...ited States other countries or both Also miniSD microSD miniSDHC microSDHC microSDXC are all trademarks or registered trademarks of SD 3C LLC in the United States other countries or both Regulatory Information Europe This product complies with the applicable CE marking directives and harmonized standards Electromagnetic Compatibility EMC Directive 2004 108 EC See Electromagnetic Compatibility EMC ...

Страница 3: ...c equipment WEEE is applicable in the European Union member states To prevent potential harm to human health and the environment the product must be disposed of in an approved and environmentally safe recycling process For information about your nearest designated collection point contact your local authority responsible for waste disposal Businesses should contact the product supplier for informa...

Страница 4: ......

Страница 5: ...zardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NO NO NOTICE TICE TICE Indicates a situation which if not avoided could result in damage to property Other Message Levels Important Indicates significant information which is essential for the product to function correc...

Страница 6: ...mpt to repair the product by yourself Contact Axis support or your Axis reseller for service matters Transportation NO NO NOTICE TICE TICE Keep the protective packaging When transporting the Axis product the protective packaging shall be replaced in its original position When transporting the Axis product use the original packaging or equivalent to prevent damage to the product Battery The Axis pr...

Страница 7: ...ossible keep the protective plastic on the dome cover until the installation is complete Do not clean a dome cover that looks clean to the eye and never polish the surface Excessive cleaning could damage the surface For general cleaning of the dome cover it is recommended to use a non abrasive solvent free neutral soap or detergent mixed with pure water and a soft clean cloth Rinse well with pure ...

Страница 8: ...8 ...

Страница 9: ...age 22 5 Access the product See page 32 Package Contents Q6042 C Q6044 C Q6045 C PTZ Dome Network Camera Clear dome cover premounted AXIS T8605 Media converter switch Multi connector cable IP66 7 m 23 ft Installation and Management Software CD Printed materials Installation Guide this document Extra serial number label 2x AVHS Authentication key Recommended Tools Wire stripping tool Phillips screw...

Страница 10: ...ries AXIS T91A Mounting Accessories For information about available accessories see www axis com Hardware Overview 1 2 3 4 Top view 1 Alignment indicator 2 Multi connector 3 Hook for safety wire 4 Unit holder 3x 10 ...

Страница 11: ...AXIS Q604 Series 1 2 3 4 5 6 Bottom view 1 Cooling system 2 Fan 3 SD card slot SDHC 4 Power button for Factory Default only 5 Control button 6 Status LED indicator 11 ENGLISH ...

Страница 12: ...AXIS Q604 Series Dome Cover 1 2 3 4 5 6 1 Dome bracket screw PH2 4x 2 Dome bracket 3 Dome cover 4 Rubber gasket 5 Dome ring 6 Dome ring screw T30 4x 12 ...

Страница 13: ...AXIS Q604 Series Sunshield 1 2 3 1 Screw hole 3x 2 Hole for unit holder 3x 3 Part number P N Serial number S N 13 ENGLISH ...

Страница 14: ...wer connector DC output 3 Network connector internal 4 Network slot SFP external 2x 5 Network connector RJ45 external 2x 6 Camera LED indicator 7 Network LED indicator 4x 8 Power LED indicator 9 Ground clip 10 I O connector internal 11 I O connector external 12 Multi connector cable 13 Ground screw 14 ...

Страница 15: ...current protection engaged power overload Power Green DC power connected Amber 10 Mbit connection Flashes during activity Network 4x Green 100 1000 Mbit connection Flashes during activity Camera Green 100 Mbit connection Flashes during activity Connectors and Buttons For specifications and operating conditions see page 18 Multi connector Terminal connector for connecting the supplied media convert...

Страница 16: ...removed The power button is also used with the control button to reset the camera to factory default settings See page 34 Media Converter Switch Connectors For specifications see page 18 NO NO NOTICE TICE TICE The product shall be connected using a shielded network cable STP or an optical fiber cable All cables connecting the product to the network shall be intended for their specific use Make sur...

Страница 17: ...ng and alarm notifications In addition to the 0 V DC reference point and power DC output the I O connector provides the interface to Digital output For connecting external devices such as relays and LEDs Connected devices can be activated by the VAPIX Application Programming Interface output buttons on the Live View page or by an Action Rule The output will show as active shown under System Option...

Страница 18: ...ted to pin 1 when activated floating unconnected when deactivated If used with an inductive load e g a relay a diode must be connected in parallel with the load for protection against voltage transients 0 to max 30 V DC open drain 100 mA RX 3 green white Ethernet receiving RX 4 green Ethernet receiving TX 5 orange white Ethernet transmitting TX 6 orange Ethernet transmitting 0 V DC 8 black 0 V DC ...

Страница 19: ... C 10 100 RH non condensing Storage Conditions Temperature AXIS Q6042 C Q6044 C Q6045 C 20 C to 75 C 4 F to 167 F Electrical Specifications NO NO NOTICE TICE TICE For confirmed compliance with the requirements for Safety Extra Low Voltage SELV and Limited Power Source LPS use the power supply sold separately recommended by Axis For information about compatible power accessories see www axis com Pr...

Страница 20: ...f storage For best recording performance use an SDHC or SDXC card with speed class 10 Media Converter Switch Connectors Camera Connectors Power connector Two 2 pin terminal blocks for power output pin 4 is not used 2 1 4 3 Function Pin Notes Specifications 12 V DC 1 2 Power out to camera Max load 6 5 A 12 0 13 2 V DC min 70 W 0 V DC 3 0 V DC DC output N a 4 N a 20 ...

Страница 21: ...n terminal block for power input 2 1 Function Pin Notes Specifications 0 V DC 1 0 V DC DC input 12 V DC 2 Power in from power supply sold separately Max load 7 A 12 0 13 2 V DC min 75 W I O terminal connector 6 pin terminal blocks for Digital Input Output Power DC output 0 V DC 2 1 4 3 6 5 Function Pin Notes Specifications 0 V DC 1 4 6 0 V DC 21 ENGLISH ...

Страница 22: ...to scratch damage or leave fingerprints on the dome cover because this could decrease image quality If possible keep the protective plastic on the dome cover until the installation is complete The Axis product can be installed with the cables routed through or along the wall or roof In areas where the temperature is above 60 C 140 F the product shall be placed in a restricted access location Read ...

Страница 23: ... and the dome cover from the dome ring 3 Make sure the rubber gasket is fitted correctly on the dome cover 4 Align the bulge on the dome cover with one of the logotypes on the dome ring 5 Attach the dome bracket and the dome cover to the dome ring and tighten the screws torque 1 2 Nm 6 To install an SD card not included see Install an SD Card on page 24 7 To attach the dome cover to the top cover ...

Страница 24: ...its have been installed by a trained professional according to the manufacturer s instructions and in compliance with local regulations The power supply sold separately and the media converter switch shall be installed in an environment protected against dust and water for example indoors or in an appropriate cabinet The product shall be connected using a shielded network cable STP or an optical f...

Страница 25: ...e jacket 5 Leave the braided shield intact but cut off 30 mm 1 18 in of the outer foil shield 6 Fold back the leftover outer foil shield and twist the braided shield into a coil 7 Cut off about 7 8 mm 0 27 0 32 in of the Ethernet wire foil shields 8 Strip off about 4 5 mm 0 16 0 20 in of the power wire jackets 25 ENGLISH ...

Страница 26: ...able jacket 2 Outer foil shield 3 Braided shield 4 Ethernet wire foil shield 2x 1 2 3 4 5 6 7 8 9 10 12 11 1 8 2 7 9 3 6 4 5 1 Power wire red 2 Digital I O wire blue 3 Ethernet wire green white 4 Ethernet wire green 5 Ethernet wire orange white 26 ...

Страница 27: ...ld coil 9 Connect the network and I O wires to the internal network and I O connectors Open the lid insert the wires and close 10 Connect the ground and power wires to the power connector DC output 1 8 9 3 4 5 6 2 7 10 11 12 13 16 14 15 17 18 1 Power wire red 2 Digital I O wire blue 3 Ethernet wire green white 4 Ethernet wire green 5 Ethernet wire orange white 27 ENGLISH ...

Страница 28: ...sert the braided shield coil into the ground clip and tighten the screws NO NO NOTICE TICE TICE The shields and the clamp surfaces shall be in full contact with each other so that the multi connector cable is grounded Make sure that the multi connector cable jacket is firmly secured by the clamp Make sure all surfaces and contacts are clean and free from scrap shield material 12 Connect the networ...

Страница 29: ...nput via the terminal block plug 15 Attach the ground wire to the ground screw 16 If connecting several media converter switches in a daisy chain set the dip switch of each outgoing network connector port that connects to another media converter switch to position C Leave the dip switch in its default position position B when connecting the port directly to the network For more information see Med...

Страница 30: ...ork LED indicator 4x ETH 1 2 3 4 3 Camera LED indicator Install the Network Camera NO NO NOTICE TICE TICE To comply with the IP66 rated design of the camera and maintain the IP66 protection the supplied multi connector cable shall be used 1 Install the selected bracket sold separately according to the instructions supplied with the bracket If drilling is required make sure to use drill bits screws...

Страница 31: ...cket sold separately 1 Slot for unit holders 3x 2 Screw T30 2x 3 Safety wire 4 Remove the protection cap covering the multi connector on the camera 5 Connect the multi connector cable to the connector on the camera Use the alignment indicators to find the correct position NO NO NOTICE TICE TICE Be careful not do damage the multi connector cable when connecting it 31 ENGLISH ...

Страница 32: ...unting bracket by tightening the screws Access the Product Use the tools provided on the Installation and Management Software CD to assign an IP address set the password and access the video stream This information is also available from the support pages on www axis com techsup Clean the Outer Heat Sink Dust and particle buildup could affect the performance of the cooling system To maintain the p...

Страница 33: ...era cool before touching it 1 Disconnect the multi connector cable 2 Loosen the screws and remove the sunshield 1 2 1 Screw T20 3x 2 Sunshield 3 Remove the screws Torx T30 and lift the heat sink cover NO NO NOTICE TICE TICE Do not strain the fan cables or let the heat sink cover hang by the fan cables 1 2 3 4 1 Heat sink cover 33 ENGLISH ...

Страница 34: ...com techsup To reset the product to the factory default settings 1 Press and hold the control button and the power button for about 15 30 seconds until the status LED indicator flashes amber See Hardware Overview on page 10 2 Release the control button but continue to hold down the power button until the status LED indicator turns green 3 Release the power button and assemble the product 4 The pro...

Страница 35: ...xis learning center www axis com academy for useful trainings webinars tutorials and guides Warranty Information For information about Axis product warranty and thereto related information see www axis com warranty 35 ENGLISH ...

Страница 36: ...Installation Guide Ver M3 2 AXIS Q604 Series Date July 2014 Axis Communications AB 2014 Part No 59053 ...