background image

Legal Considerations

Video surveillance can be regulated by laws that vary from

country to country. Check the laws in your local region
before using this product for surveillance purposes.
This product includes one (1) H.264 decoder license. To
purchase further licenses, contact your reseller.

Liability

Every care has been taken in the preparation of this
document. Please inform your local Axis office of any
inaccuracies or omissions. Axis Communications AB cannot
be held responsible for any technical or typographical errors
and reserves the right to make changes to the product and
manuals without prior notice. Axis Communications AB
makes no warranty of any kind with regard to the material
contained within this document, including, but not limited

to, the implied warranties of merchantability and fitness for
a particular purpose. Axis Communications AB shall not

be liable nor responsible for incidental or consequential
damages in connection with the furnishing, performance

or use of this material. This product is only to be used for
its intended purpose.

Intellectual Property Rights

Axis AB has intellectual property rights relating to
technology embodied in the product described in this
document. In particular, and without limitation, these
intellectual property rights may include one or more of
the patents listed at

www.axis.com/patent.htm

and one or

more additional patents or pending patent applications in

the US and other countries.
This product contains licensed third-party software. See

the menu item “About” in the product’s user interface for

more information.
This product contains source code copyright Apple Computer,

Inc., under the terms of Apple Public Source License 2.0

(see

www.opensource.apple.com/apsl

). The source code is

available from

https://developer.apple.com/bonjour/

Equipment Modifications

This equipment must be installed and used in

strict accordance with the instructions given in the

user documentation. This equipment contains no

user-serviceable components. Unauthorized equipment
changes or modifications will invalidate all applicable

regulatory certifications and approvals.

Trademark Acknowledgments

AXIS COMMUNICATIONS, AXIS, ETRAX, ARTPEC and VAPIX

are registered trademarks or trademark applications of Axis

AB in various jurisdictions. All other company names and

products are trademarks or registered trademarks of their
respective companies.
Apple, Boa, Apache, Bonjour, Ethernet, Internet Explorer,
Linux, Microsoft, Mozilla, Real, SMPTE, QuickTime, UNIX,

Windows, Windows Vista and WWW are registered

trademarks of the respective holders. Java and all

Java-based trademarks and logos are trademarks or
registered trademarks of Oracle and/or its affiliates.

UPnP

TM

is a certification mark of the UPnP

TM

Implementers

Corporation.
SD, SDHC and SDXC are trademarks or registered trademarks
of SD-3C, LLC in the United States, other countries or both.
Also, miniSD, microSD, miniSDHC, microSDHC, microSDXC
are all trademarks or registered trademarks of SD-3C, LLC
in the United States, other countries or both.

Regulatory Information

Europe

This product complies with the applicable CE marking

directives and harmonized standards:

Electromagnetic Compatibility (EMC) Directive
2004/108/EC. See

Electromagnetic Compatibility (EMC)

on page 2

.

Low Voltage (LVD) Directive 2006/95/EC. See

Safety

on page 3

.

Restrictions of Hazardous Substances (RoHS) Directive
2011/65/EU. See

Disposal and Recycling on page 3

.

A copy of the original declaration of conformity may be
obtained from Axis Communications AB. See

Contact

Information on page 3

.

Electromagnetic Compatibility (EMC)

This equipment has been designed and tested to fulfill
applicable standards for:

Radio frequency emission when installed according to

the instructions and used in its intended environment.

Immunity to electrical and electromagnetic phenomena
when installed according to the instructions and used
in its intended environment.

USA

This equipment has been tested using a shielded network
cable (STP) and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection
against harmful interference when the equipment is
operated in a commercial environment. This equipment

generates, uses, and can radiate radio frequency energy

and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in

a residential area is likely to cause harmful interference

in which case the user will be required to correct the

interference at his own expense.
The product shall be connected using a shielded network

cable (STP) that is properly grounded.

Canada

This Class A digital apparatus complies with Canadian

ICES-003. The product shall be connected using a shielded

network cable (STP) that is properly grounded.
Cet appareil numérique de la classe A est confome à la

norme NMB-003 du Canada. Le produit doit être connecté

à l'aide d'un câble réseau blindé (STP) qui est correctement

mis à la terre.

Europe

This digital equipment fulfills the requirements for RF

emission according to the Class A limit of EN 55022. The
product shall be connected using a shielded network cable

(STP) that is properly grounded. Notice! This is a Class A

product. In a domestic environment this product may cause

RF interference, in which case the user may be required
to take adequate measures.
This product fulfills the requirements for emission and
immunity according to EN 50121-4 and IEC 62236-4 railway

applications.
This product fulfills the requirements for immunity
according to EN 61000-6-1 residential, commercial and
light-industrial environments.
This product fulfills the requirements for immunity
according to EN 61000-6-2 industrial environments.
This product fulfills the requirements for immunity
according to EN 55024 office and commercial environments

Содержание Q6042-C

Страница 1: ...AXIS Q604 Series AXIS Q6042 C PTZ Dome Network Camera AXIS Q6044 C PTZ Dome Network Camera AXIS Q6045 C PTZ Dome Network Camera ENGLISH Installation Guide ...

Страница 2: ...ited States other countries or both Also miniSD microSD miniSDHC microSDHC microSDXC are all trademarks or registered trademarks of SD 3C LLC in the United States other countries or both Regulatory Information Europe This product complies with the applicable CE marking directives and harmonized standards Electromagnetic Compatibility EMC Directive 2004 108 EC See Electromagnetic Compatibility EMC ...

Страница 3: ...c equipment WEEE is applicable in the European Union member states To prevent potential harm to human health and the environment the product must be disposed of in an approved and environmentally safe recycling process For information about your nearest designated collection point contact your local authority responsible for waste disposal Businesses should contact the product supplier for informa...

Страница 4: ......

Страница 5: ...zardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NO NO NOTICE TICE TICE Indicates a situation which if not avoided could result in damage to property Other Message Levels Important Indicates significant information which is essential for the product to function correc...

Страница 6: ...mpt to repair the product by yourself Contact Axis support or your Axis reseller for service matters Transportation NO NO NOTICE TICE TICE Keep the protective packaging When transporting the Axis product the protective packaging shall be replaced in its original position When transporting the Axis product use the original packaging or equivalent to prevent damage to the product Battery The Axis pr...

Страница 7: ...ossible keep the protective plastic on the dome cover until the installation is complete Do not clean a dome cover that looks clean to the eye and never polish the surface Excessive cleaning could damage the surface For general cleaning of the dome cover it is recommended to use a non abrasive solvent free neutral soap or detergent mixed with pure water and a soft clean cloth Rinse well with pure ...

Страница 8: ...8 ...

Страница 9: ...age 22 5 Access the product See page 32 Package Contents Q6042 C Q6044 C Q6045 C PTZ Dome Network Camera Clear dome cover premounted AXIS T8605 Media converter switch Multi connector cable IP66 7 m 23 ft Installation and Management Software CD Printed materials Installation Guide this document Extra serial number label 2x AVHS Authentication key Recommended Tools Wire stripping tool Phillips screw...

Страница 10: ...ries AXIS T91A Mounting Accessories For information about available accessories see www axis com Hardware Overview 1 2 3 4 Top view 1 Alignment indicator 2 Multi connector 3 Hook for safety wire 4 Unit holder 3x 10 ...

Страница 11: ...AXIS Q604 Series 1 2 3 4 5 6 Bottom view 1 Cooling system 2 Fan 3 SD card slot SDHC 4 Power button for Factory Default only 5 Control button 6 Status LED indicator 11 ENGLISH ...

Страница 12: ...AXIS Q604 Series Dome Cover 1 2 3 4 5 6 1 Dome bracket screw PH2 4x 2 Dome bracket 3 Dome cover 4 Rubber gasket 5 Dome ring 6 Dome ring screw T30 4x 12 ...

Страница 13: ...AXIS Q604 Series Sunshield 1 2 3 1 Screw hole 3x 2 Hole for unit holder 3x 3 Part number P N Serial number S N 13 ENGLISH ...

Страница 14: ...wer connector DC output 3 Network connector internal 4 Network slot SFP external 2x 5 Network connector RJ45 external 2x 6 Camera LED indicator 7 Network LED indicator 4x 8 Power LED indicator 9 Ground clip 10 I O connector internal 11 I O connector external 12 Multi connector cable 13 Ground screw 14 ...

Страница 15: ...current protection engaged power overload Power Green DC power connected Amber 10 Mbit connection Flashes during activity Network 4x Green 100 1000 Mbit connection Flashes during activity Camera Green 100 Mbit connection Flashes during activity Connectors and Buttons For specifications and operating conditions see page 18 Multi connector Terminal connector for connecting the supplied media convert...

Страница 16: ...removed The power button is also used with the control button to reset the camera to factory default settings See page 34 Media Converter Switch Connectors For specifications see page 18 NO NO NOTICE TICE TICE The product shall be connected using a shielded network cable STP or an optical fiber cable All cables connecting the product to the network shall be intended for their specific use Make sur...

Страница 17: ...ng and alarm notifications In addition to the 0 V DC reference point and power DC output the I O connector provides the interface to Digital output For connecting external devices such as relays and LEDs Connected devices can be activated by the VAPIX Application Programming Interface output buttons on the Live View page or by an Action Rule The output will show as active shown under System Option...

Страница 18: ...ted to pin 1 when activated floating unconnected when deactivated If used with an inductive load e g a relay a diode must be connected in parallel with the load for protection against voltage transients 0 to max 30 V DC open drain 100 mA RX 3 green white Ethernet receiving RX 4 green Ethernet receiving TX 5 orange white Ethernet transmitting TX 6 orange Ethernet transmitting 0 V DC 8 black 0 V DC ...

Страница 19: ... C 10 100 RH non condensing Storage Conditions Temperature AXIS Q6042 C Q6044 C Q6045 C 20 C to 75 C 4 F to 167 F Electrical Specifications NO NO NOTICE TICE TICE For confirmed compliance with the requirements for Safety Extra Low Voltage SELV and Limited Power Source LPS use the power supply sold separately recommended by Axis For information about compatible power accessories see www axis com Pr...

Страница 20: ...f storage For best recording performance use an SDHC or SDXC card with speed class 10 Media Converter Switch Connectors Camera Connectors Power connector Two 2 pin terminal blocks for power output pin 4 is not used 2 1 4 3 Function Pin Notes Specifications 12 V DC 1 2 Power out to camera Max load 6 5 A 12 0 13 2 V DC min 70 W 0 V DC 3 0 V DC DC output N a 4 N a 20 ...

Страница 21: ...n terminal block for power input 2 1 Function Pin Notes Specifications 0 V DC 1 0 V DC DC input 12 V DC 2 Power in from power supply sold separately Max load 7 A 12 0 13 2 V DC min 75 W I O terminal connector 6 pin terminal blocks for Digital Input Output Power DC output 0 V DC 2 1 4 3 6 5 Function Pin Notes Specifications 0 V DC 1 4 6 0 V DC 21 ENGLISH ...

Страница 22: ...to scratch damage or leave fingerprints on the dome cover because this could decrease image quality If possible keep the protective plastic on the dome cover until the installation is complete The Axis product can be installed with the cables routed through or along the wall or roof In areas where the temperature is above 60 C 140 F the product shall be placed in a restricted access location Read ...

Страница 23: ... and the dome cover from the dome ring 3 Make sure the rubber gasket is fitted correctly on the dome cover 4 Align the bulge on the dome cover with one of the logotypes on the dome ring 5 Attach the dome bracket and the dome cover to the dome ring and tighten the screws torque 1 2 Nm 6 To install an SD card not included see Install an SD Card on page 24 7 To attach the dome cover to the top cover ...

Страница 24: ...its have been installed by a trained professional according to the manufacturer s instructions and in compliance with local regulations The power supply sold separately and the media converter switch shall be installed in an environment protected against dust and water for example indoors or in an appropriate cabinet The product shall be connected using a shielded network cable STP or an optical f...

Страница 25: ...e jacket 5 Leave the braided shield intact but cut off 30 mm 1 18 in of the outer foil shield 6 Fold back the leftover outer foil shield and twist the braided shield into a coil 7 Cut off about 7 8 mm 0 27 0 32 in of the Ethernet wire foil shields 8 Strip off about 4 5 mm 0 16 0 20 in of the power wire jackets 25 ENGLISH ...

Страница 26: ...able jacket 2 Outer foil shield 3 Braided shield 4 Ethernet wire foil shield 2x 1 2 3 4 5 6 7 8 9 10 12 11 1 8 2 7 9 3 6 4 5 1 Power wire red 2 Digital I O wire blue 3 Ethernet wire green white 4 Ethernet wire green 5 Ethernet wire orange white 26 ...

Страница 27: ...ld coil 9 Connect the network and I O wires to the internal network and I O connectors Open the lid insert the wires and close 10 Connect the ground and power wires to the power connector DC output 1 8 9 3 4 5 6 2 7 10 11 12 13 16 14 15 17 18 1 Power wire red 2 Digital I O wire blue 3 Ethernet wire green white 4 Ethernet wire green 5 Ethernet wire orange white 27 ENGLISH ...

Страница 28: ...sert the braided shield coil into the ground clip and tighten the screws NO NO NOTICE TICE TICE The shields and the clamp surfaces shall be in full contact with each other so that the multi connector cable is grounded Make sure that the multi connector cable jacket is firmly secured by the clamp Make sure all surfaces and contacts are clean and free from scrap shield material 12 Connect the networ...

Страница 29: ...nput via the terminal block plug 15 Attach the ground wire to the ground screw 16 If connecting several media converter switches in a daisy chain set the dip switch of each outgoing network connector port that connects to another media converter switch to position C Leave the dip switch in its default position position B when connecting the port directly to the network For more information see Med...

Страница 30: ...ork LED indicator 4x ETH 1 2 3 4 3 Camera LED indicator Install the Network Camera NO NO NOTICE TICE TICE To comply with the IP66 rated design of the camera and maintain the IP66 protection the supplied multi connector cable shall be used 1 Install the selected bracket sold separately according to the instructions supplied with the bracket If drilling is required make sure to use drill bits screws...

Страница 31: ...cket sold separately 1 Slot for unit holders 3x 2 Screw T30 2x 3 Safety wire 4 Remove the protection cap covering the multi connector on the camera 5 Connect the multi connector cable to the connector on the camera Use the alignment indicators to find the correct position NO NO NOTICE TICE TICE Be careful not do damage the multi connector cable when connecting it 31 ENGLISH ...

Страница 32: ...unting bracket by tightening the screws Access the Product Use the tools provided on the Installation and Management Software CD to assign an IP address set the password and access the video stream This information is also available from the support pages on www axis com techsup Clean the Outer Heat Sink Dust and particle buildup could affect the performance of the cooling system To maintain the p...

Страница 33: ...era cool before touching it 1 Disconnect the multi connector cable 2 Loosen the screws and remove the sunshield 1 2 1 Screw T20 3x 2 Sunshield 3 Remove the screws Torx T30 and lift the heat sink cover NO NO NOTICE TICE TICE Do not strain the fan cables or let the heat sink cover hang by the fan cables 1 2 3 4 1 Heat sink cover 33 ENGLISH ...

Страница 34: ...com techsup To reset the product to the factory default settings 1 Press and hold the control button and the power button for about 15 30 seconds until the status LED indicator flashes amber See Hardware Overview on page 10 2 Release the control button but continue to hold down the power button until the status LED indicator turns green 3 Release the power button and assemble the product 4 The pro...

Страница 35: ...xis learning center www axis com academy for useful trainings webinars tutorials and guides Warranty Information For information about Axis product warranty and thereto related information see www axis com warranty 35 ENGLISH ...

Страница 36: ...Installation Guide Ver M3 2 AXIS Q604 Series Date July 2014 Axis Communications AB 2014 Part No 59053 ...