AXIS Q1755-E Installation Guide
Page 15
ENGL
IS
H
Set the password
To gain access to the product, the password for the default administrator user
root
must be set. This
is done in the ‘
Configure Root Password
’ dialog, which is displayed when the network camera is
accessed for the first time.
To prevent network eavesdropping when setting the root password, this can be done via an
encrypted HTTPS connection, which requires an HTTPS certificate.
Note:
HTTPS (Hypertext Transfer Protocol over SSL) is a protocol used to encrypt the traffic between web
browsers and servers. The HTTPS certificate controls the encrypted exchange of information.
To set the password via a standard HTTP connection, enter it directly in the first dialog shown
below.
To set the password via an encrypted HTTPS connection, follow these steps:
1. Click the
Create self-signed certificate
button.
2. Provide the requested information and click
OK
. The certificate is created and the password can
now be set securely. All traffic to and from the network camera is encrypted from this point on.
3. Enter a password and then re-enter it to confirm the spelling. Click
OK
. The password has now
been configured.
4. To log in, enter the user name “root” in the dialog as requested
Note:
The default administrator user name root cannot be deleted.
5. Enter the password as set above, and click OK.
Note:
If the password is lost, the camera must be reset to the factory default settings. See page 22.
To configure the password directly
via an unencrypted connection, enter
the password here.
To create an HTTPS connection,
start by clicking this button.
Содержание Q1755-E
Страница 1: ...ENGLISH DEUTSCH ITALIANO ESPAÑOL INSTALLATION GUIDE FRANÇAIS AXIS Q1755 E Network Camera ...
Страница 5: ......
Страница 25: ......
Страница 45: ......
Страница 47: ......
Страница 67: ......
Страница 69: ......
Страница 89: ......
Страница 91: ......
Страница 111: ......
Страница 112: ......
Страница 113: ...Installation Guide Ver 1 3 AXIS Q1755 E Printed April 2014 Axis Communications AB 2010 2013 Part No 57193 ...