Page 22
AXIS P33-VE Series Installation Guide
Open the
Live View
page in the web interface and make the following adjustments to the camera:
1. Loosen the locking screw and tilt adjustment screws.
2. Turn the lens (with the lens holder) to the desired position. Make sure the horizontal lines on
either side of the lens are aligned horizontally
Ensure that the mark on the lens cover, between the horizontal lines, is facing up.
3. Once satisfied, gently tighten the locking screw and tilt adjustment screws to secure the
camera’s position.
4. Open the
Focus Adjustment
page in the Web interface under
Setup > Basic Setup > Focus &
Zoom
, and follow the on-screen instructions. Use the image window to adjust the focus and
zoom. See the online help files for more information.
Due to the dome’s refraction, the image may appear slightly out of focus once the dome
has been placed. To correct this go to the
Focus Adjustment
page in the Web interface
under
Setup > Basic Setup > Focus & Zoom
, and adjust the focus again.
Locking screw
Tilt adjustment screw
Horizontal line
Tilt adjustment screw