To leave the function with clearing the adding register, enter 

F..-tot

 function menu 

and  choose 

F..-1

  option.  When  connected  to  a  printer,  the  balance  prints  the 

communicate informing about clearing the register.

 

 
The sample check for each measurement: 
 

 
 
 

 
 

Report printout sample: 

 

 

 
 
 
 
 
 
 

Note:  

When  the  balance  has  not  an  internal  clock,  Date  and  Time  do  not  appear 
on printout. Maximum number of measurements 99 999.  
Maximum total load 99 999 000d.  
The weighing unit of the aggregated value from the register (total) is the same as 
the  weighing  unit  stated  on  the  keypad  or  is  1000  times  greater  (signalised  with 
“o” indicator at the left of the display).  
If the registered value is too big to be displayed, “E” communicate appears on the 
display.  
If  the  number  of  series  is  too high to be displayed,  “Err1”communicate  appears 
on the display. 
 

 

  Date:            ...             Time   ... 
  measurement no          weight           
  measurement no          weight           
           …                           … 

  Date:            ...      Time   ... 
  TOTAL WEIGHT 

  NUMBER OF SAMPLES  = 
  AVERAGE VALUE 

Содержание LCD GB V4

Страница 1: ...SPECIAL FUNCTIONS DESCRIPTION USER MANUAL COMPLEMENT b series File EO F 005 01 08 b 41_3 LCD GB v 4 ...

Страница 2: ... information 3 2 Keys and indicators 4 3 Date and time setting dAtE 5 4 Formulation function SU 6 5 Average calculation SrE 7 6 Percentage weighing F Pro 8 7 Animal weighing LOC 9 8 Maximum value UP 10 9 Anti disturbance filter FIL 11 10 Checkweighing thr 12 11 Total weight function totAL 15 12 Density determination hYdro 17 13 Function Menu customisation F ACt 19 ...

Страница 3: ...g autozero serial port working mode setting serial port parameters setting constant tare calibration options On customers request balances may be equipped with additional set of special functions including percentage weighing formulation animal weighing maximum value anti stroke filter checkweighing paper substance determination total weight function liquid and solids density determination This br...

Страница 4: ...t key switch on switch off standby indicator 0 zero indicator indicator result stabilisation indicator indicator NET net weight indicator indication with subtracted tare indicator MODE special function mode indicator bar indicator total load indicator graduated 0 100 indicator OFF standby switched off with key indicator B G gross weigh indicator after pressing B G key indicator pcs number of piece...

Страница 5: ...ntouts Options F 0 deactivate date printout F 1 activate date printout key F 2 change date and time The example at the left presents how to set current date and time with F 2 option Change successive numbers using 0 key To move to the next position use T key Once current date and time is set activate it with F 1 option Time format h gg mm gg hour m minute Date format d mm dd m month d day Year for...

Страница 6: ...ghing each of successive recipe ingredients A B C etc make sure the balance displays zero indication or simply tare the balance with T key To display aggregated sum of series of measurements press MENU key choose SU function and use F 0 option Aggregated weight of the recipe is displayed when SUM indicator is lit Whilst SUM indicator is displayed it is possible to return to the previous formula wi...

Страница 7: ...h stable result for average value calculation Pay attention that the value is registered only when the result is stable Remove the load only after communicate is displayed The balance registers the results above Min balance value only The number of successive measurements is limited to 9999 Press key several times to display average calculation information in the sequence given below number of mea...

Страница 8: ...displayed in different format depending on the reference sample weight value For values of 0 3 5 of weighing range the format is 100 0 for values 3 5 35 it is 100 00 and 35 100 100 00 The function has the following options F 0 disables the function F 1 stores current indication as 100 and activates percentage weighing F 2 activates percentage weighing with the previous reference sample value sign ...

Страница 9: ...lly with key For automatic weighing press T key when F 1 is displayed Tare the balance when necessary and place the animal on the pan Wait until the weighing result is averaged the indication blinks Final result is displayed on the display and send via serial port to computer or printer Remove the animal from the pan the result is displayed for 30s and then the balance starts the new measurement I...

Страница 10: ...re the balance displays zero indication before starting measurements Enter the function menu with MENU key and choose F UP function The displayed indication is the highest value from the series of measurements Press T key to zero the indication Note Autozero function and the stabilisation indicator are deactivated when UP function is active The indication is the result of continuous averaging of 5...

Страница 11: ... vibrations on measurement result Using the filter is necessary for accurate people or animal weighing Press MENU key and choose F FIL with T key The following options appears F 0 filter deactivated F 1 filter I weak F 2 filter II average F 3 filter III intense F 4 filter IV very intense Choose the filter of desired intensity the balance is now operating with selected filter To return to normal wo...

Страница 12: ...splayed F 0 deactivate the function F 1 activate the function F P check current threshold values use to display successive values Choose F 0 option with T key Following options are displayed SEt 0 start the function with the excess signalisation SEt 1 set lower threshold value SEt 2 set lower threshold value SEt 3 set zero excess signalisation Set the lower and the upper threshold values with the ...

Страница 13: ...Dosing option is installed on customer s request to change external device mode service intervention is necessary Threshold comparison results appear on P1 P3 output pins as a short circuit state presented on the state chart on the next page During dosing optional short circuit pulses lasting for 0 5s appear on P1 I threshold and P2 II threshold outputs and for P3 output zero threshold short circu...

Страница 14: ..._____________________________________________________________________________________________ Output state charts increasing load External optical indicator Dosing optional P3 P1 P2 P3 zero zero treshold treshold thr I thr I thr I thr II thr II thr II P1 P2 ...

Страница 15: ... adding register F 0 report printout with clearing the adding register F 1 report printout after each measurement F 2 report printout disabled Press T key when F 1 is displayed Place successive samples on the pan and press after each measurement to store the value in the adding register To display current results enter F tot function menu and choose F P option The results are display in the follow...

Страница 16: ...balance has not an internal clock Date and Time do not appear on printout Maximum number of measurements 99 999 Maximum total load 99 999 000d The weighing unit of the aggregated value from the register total is the same as the weighing unit stated on the keypad or is 1000 times greater signalised with o indicator at the left of the display If the registered value is too big to be displayed E comm...

Страница 17: ...er choose F hYd and use F 2 option to enter its density according to its temperature To enter the value use the following keys 0 digit increase decimal point T next digit MENU end The measurement is performed in three phases measurement in air measurement in liquid hanger weighing To read density determination result enter F hYd function menu and use F P option Press key to display successive meas...

Страница 18: ... print a density determination report after all necessary measurements connect a printer to the balance Operation sequence weighing in air and in liquid for below balance weighing Phase I measurement in air Phase II measurement in liquid Date Time MEASUREMENT No WEIGHT in air g WEIGHT in liquid g HANGER WEIGHT g LOAD DENSITY g cm3 LIQUID DENSITY g cm3 ...

Страница 19: ... to select special functions that will be displayed after pressing MENU key Easy access to the most useful functions will shorten operation time and make work more comfortable Operation sequence shown on the picture presents how to add RS232C parameters setting function F rS to the Function Menu To remove a function from the Function Menu choose F 0 in the last operation 0 00 F ACt F 1 F 0 F1 AUt ...

Страница 20: ...20 SPECIAL FUNCTIONS DESCRIPTION ____________________________________________________________________________________________________________________ ...

Отзывы: