Charger Error & Fault Codes Table
Code
Description
Solution
E-0-0-1
E-0-2-1
Battery high voltage
Possible causes: wrong battery voltage for charger, other charger also attached,
resistive battery. Possible solutions: check the battery voltage and cable
connections. Check battery size and condition. This error will automatically clear
once the voltage is in range.
E-0-0-2
E-0-2-2
Battery low voltage
Possible causes: battery disconnected, battery overdischarged. Possible solutions:
check the battery voltage and cable connections. Check battery size and
condition. This error will automatically clear once the voltage is in range.
E-0-0-3
Charge timeout caused
by battery pack not
reaching required
voltage within safe
time limit. (charge
profile dependent)
Possible causes: charger output reduced due to high temperatures, poor battery
health, very deeply discharged battery and /or poorly connected battery. Possible
solutions: operate at lower ambient temperature. Replace battery pack. Check DC
connections. This error will clear once the charger is reset by cycling DC or AC.
E-0-0-4
Battery could not
meet minimum
voltage (charge profile
dependent)
Possible causes: check for shorted or damaged cells. Possible solutions: replace
battery pack. Check DC connections. This error will automatically clear once the
charger is reset by cycling DC or AC.
E-0-0-7
Battery amp hour limit
exceeded
Possible causes: poor battery health, very deeply discharged battery, poorly
connected battery, and / or high parasitic loads on battery while charging. Possible
solutions: replace battery pack. Check DC connections. Disconnect parasitic loads.
This error will automatically clear once the charger is reset by cycling DC or AC.
E-0-0-8
Battery temperature is
out of range
Possible battery temperature sensor error. Check temperature sensor and
connections. Reset charger. This error will clear once the condition has been
corrected.
E-0-1-2
Reverse polarity error
Battery is connected to the charger incorrectly. Check the battery connections.
This error will clear once the condition has been corrected.
E-0-1-6
E-0-1-8
E-0-2-6
USB operation failed
(software)
Software upgrade failure or script operation failure. Ensure the USB flash drive is
properly formatted and reinsert the USB flash drive.
E-0-1-7
USB operation failed
(hardware)
Remove and reinsert the USB drive. If condition persists, cycle AC and retry by
reinserting the USB drive.
E-0-2-3
High AC voltage error
(>270VAC)
Connect charger to an AC source that provides stable AC between 85 - 270 VAC /
45-65 Hz. This error will clear once the condition has been corrected.
E-0-2-4
Charger failed to
initialize
The charger has failed to turn on properly. Disconnect AC input and battery for 30
seconds before retrying.
E-0-2-5
Low AC voltage
oscillation error
AC source is unstable. Could be caused by undersized generator and /or severely
undersized input cables. Connect charger to an AC source that provides stable AC
between 85 - 270 VAC / 45-65 Hz. This error will clear once the condition has been
corrected.
F-0-0-1, F-0-0-2
F-0-0-3, F-0-0-4
F-0-0-6
Internal charger fault. Remove AC and battery for minimum 30 seconds and
retry charger. If it fails again, please contact the manufacturer of your vehicle or
machine.
This is a Class A product complying with United States Federal Communications Commission, Code of Federal Regulations;
47CFR part 15. In a domestic environment, this product may cause radio interference, in which case the user may be
required to take adequate measures.
Содержание E1
Страница 1: ......
Страница 5: ...4 Cleaning and Storage 71 Storing the Vehicle 74 Specifications Table 75 ...
Страница 16: ...15 5 6 7 8 ...
Страница 33: ...32 FAULT CODE ...
Страница 34: ...FAULT CODE ...
Страница 74: ......