AXIS P33 Network Camera Series
Specifications
1 Tip
2 Ring
3 Sleeve
Audio Input
Microphone/Line in
Microphone bias voltage
Ground
Audio Output
Line out, mono
Line out, mono
Ground
The internal microphone is used by default; the external microphone is used when connected. You can disable the internal
microphone by connecting a plug to the microphone input.
For audio in, the left channel is used from a stereo signal.
I/O connector
Use the I/O connector with external devices in combination with, for example, motion detection, event triggering, and alarm
notifications. In addition to the 0 V DC reference point and power (DC output), the I/O connector provides the interface to:
Digital input -
For connecting devices that can toggle between an open and closed circuit, for example PIR sensors, door/window
contacts, and glass break detectors.
Supervised input -
Enables possibility to detect tampering on a digital input.
Digital output -
For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX®
Application Programming Interface or from the product’s webpage.
4-pin terminal block
Function
Pin
Notes
Specifications
DC ground
1
0 V DC
DC output
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
12 V DC
Max load = 25 mA
Digital Input or
Supervised Input
3
Connect to pin 1 to activate, or leave floating (unconnected)
to deactivate. To use supervised input, install end-of-line
resistors. See connection diagram for information about how
to connect the resistors.
0 to max 30 V DC
Digital Output
4
Internally connected to pin 1 (DC ground) when active,
and floating (unconnected) when inactive. If used with an
inductive load, e.g., a relay, connect a diode in parallel with
the load, to protect against voltage transients.
0 to max 30 V DC, open drain,
100 mA
Example
27