AIE800-904-FL Series U

ser’s Manual 

 

Introduction

 

5.

 

100 ~ 240 VAC wide range power input with 10kV surge  protection  

6. 1 IEEE 802.3at GbE PoE (30W) 

7.

 

Flexible I/O for customized and mission-critical projects 

 

 

Reliable and Stable Design 

 

Powered  by  the 

NVIDIA® Jetson Xavier™ NX SoM, the AIE800-904-FL is equipped 

with  M12  lockable  connectors  while  supporting  a  wall  mount  /  VESA  mount  kit  for 
outdoor applications. 

 

 

JetPack Supported 

The  AIE800-904-FL  supports  JetPack  4.4  NVIDIA  JetPack  SDK  is  the  most 

comprehensive solution for building AI applications. All Jetson modules are supported by 
JetPack SDK.  

 

 

JetPack SDK includes the Linux Driver Package (L4T) with Linux operating system and 
CUDA-X accelerated libraries and APIs for Deep Learning, Computer Vision, Accelerated 
Computing and Multimedia. It also includes samples, documentation, and developer tools 
for  both  host  computer  and  AIE  series,  and  supports  higher  level  SDKs  such  as 
DeepStream for streaming video analytics and Isaac for robotics. 

 

 

O.S. Supported 

The AIE800-904-FL supports Linux Ubuntu 18.04.  

 

 

Various Storage devices supported 

For  optimized  storage  capacity,  the  AIE800-904-FL  supports  one  M.2  Key  B  2242  with 
PCI-Express 2.0 x2 Interface (supports NVMe SSD), and an onboard 16GB eMMC (via 
Jetson Xavier™ NX). 

 

 

1.2

  

System Specifications 

1.2.1  Product Specification 

 

CPU Board 

 

    NVIDIA®  Jetson Xavier

 NX 

 

CPU 

 

    6-core NVIDIA Carmel ARM®  v8.2 64-bit CPU 6 MB L2 + 4 MB L3 

 

GPU 

 

    384-

core NVIDIA Volta™ GPU with 48 Tensor Cores 

 

Storage 

 

    16GB eMMC onboard 

 

    One M.2 Key B 2242 with PCI-Express 2.0 x2 NVMe SSD slot 

 

System Memory 

 

 

    One 8GB 128-bit LPDDR4x onboard 

 

WLAN & WWAN

 

 

    

Supports

  Wi-Fi/Bluetooth/

3G/LTE/GPS  through  an  optional  Mini  PCI-Express 

module

 

 

Содержание AIE800-904-FL Series

Страница 1: ...AIE800 904 FL Series Embedded System User s Manual...

Страница 2: ...or revise this document and or product at any time without notice No part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechani...

Страница 3: ...ake sure the voltage of the power source is correct before connecting it to any power outlet 5 Turn off system power before cleaning Clean the system using a cloth only Do not spray any liquid cleaner...

Страница 4: ...ce of a flammable anesthetic mixture with air oxygen or nitrous oxide 4 Mode of operation Continuous Note All I O connectors should be connected with corresponding cables when the system is operating...

Страница 5: ...on to components requiring designated products for cleaning as mentioned below Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used o...

Страница 6: ...a trademark of Axiomtek Co Ltd IBM PC AT PS 2 VGA are trademarks of International Business Machines Corporation Intel and Pentium are registered trademarks of Intel Corporation NVIDIA and Jetson Jets...

Страница 7: ...WARE INSTALLATION 9 2 1 M 2 SSD Installation 10 2 2 Installation of LTE Mini PCIe Module 12 SECTION 3 JUMPER CONNECTOR SETTINGS 15 3 1 Jumper Connector Location 15 3 2 Jumper Setting Summary 17 3 3 Co...

Страница 8: ...viii This page is intentionally left blank...

Страница 9: ...this ruggedized box PC adopts a fanless and streamlined enclosure made from IP67 rated aluminum die casting and heavy duty steel The AIE800 904 FL is designed to operate under a wide temperature rang...

Страница 10: ...er Vision Accelerated Computing and Multimedia It also includes samples documentation and developer tools for both host computer and AIE series and supports higher level SDKs such as DeepStream for st...

Страница 11: ...ports 4 antenna openings and comes with two pre installed LTE and two pre installed Wi Fi RF cables before shipment One M12 S Code 4 pos AC in power input 1 2 3 System Specification Watchdog Timer Sup...

Страница 12: ...AIE800 904 FL Series User s Manual 4 Introduction 1 3 Dimensions The following diagrams show the dimensions and outlines of the AIE800 904 FL 1 3 1 System Dimensions...

Страница 13: ...AIE800 904 FL Series User s Manual Introduction 5 1 3 2 Wall mount Bracket Dimensions...

Страница 14: ...AIE800 904 FL Series User s Manual 6 Introduction 1 3 3 VESA mount Bracket Dimensions...

Страница 15: ...AIE800 904 FL Series User s Manual Introduction 7 1 4 I O Outlets The following figures show I O outlets on the front of the AIE800 904 FL Top View Bottom View...

Страница 16: ...1 Screws pack x 1 Thermal pad kit x 1 Regarding the latest product manual please download them from Axiomtek official website 1 6 Model List AIE800 904 FL Rugged IP67 rated Fanless Edge AI System with...

Страница 17: ...contains guidelines for hardware installation Caution Waterproof capability may be affected if the system is improperly disassembled Under such circumstances Axiomtek shall not be held liable for any...

Страница 18: ...2 Turn the system upside down to locate and loosen the six screws at the bottom as marked by the red circles in the figure below Then remove the bottom cover Step 3 After removing the bottom cover loc...

Страница 19: ...a 30 degree angle up from the horizontal slowly insert the golden finger into the M 2 2242 Key B slot until it is fully inserted in place And secure the M 2 2242 Key B SSD card to the carrier by tigh...

Страница 20: ...te and loosen the six screws at the bottom as marked by the red circles in the figure below Then remove the bottom cover Step 3 After removing the bottom cover locate the PCI Express mini card slot on...

Страница 21: ...2 3L screw to the marked position Step 6 Find the SMA cables from the adhesive backed cord clip attached to the chassis as shown in the picture below Note The LTE and Wi Fi modules come with different...

Страница 22: ...AIE800 904 FL Series User s Manual 14 Hardware Installation This page is intentionally left blank...

Страница 23: ...MPER CONNECTOR SETTINGS Proper jumper settings configure the AIE800 904 FL to meet your application purpose This section explains all jumpers and connectors as well as their default settings for onboa...

Страница 24: ...per Connector Settings Carrier Board Bottom View Note We strongly recommended that you should not modify any unmentioned jumper setting without Axiomtek FAE s instruction Any modification without inst...

Страница 25: ...summary table of all jumpers and default settings for onboard devices respectively Carrier Board Jumper Switch Descriptions Settings JP1 Force Recovery Mode Force Recovery Mode 1 2 Close Normal Mode 2...

Страница 26: ...ut Connector M12 X Code 8 pos Female 3 3 1 USB 2 0 Connector C3 Type 4 pos Female 3 3 2 AC Power Jack Connector M12 S Code 4 pos Male 3 3 3 HDMI Connector C3 Type 19 pos Female 3 3 4 Internal Connecto...

Страница 27: ...s connectors are compliant with USB 2 0 480Mbps ideal for installing USB peripherals such as the keyboard mouse scanner etc Pin Signal 1 USB_PWR3 2 USB_PN6 3 USB_PP6 4 GND 3 3 3 AC Power Jack Connecto...

Страница 28: ...e 3 3 5 Micro USB 2 0 Connector CN1 The CN1 is specifically designed for image flashing only To flash Jetpack please set JP1 to Force Recovery before booting up the system which would force the system...

Страница 29: ...M 2 2242 Key B PCIex2 NVM Express SSD for storage use Pin Signal Pin Signal Pin Signal 1 GND 2 3 3V 3 GND 4 3 3V 5 GND 6 NC 7 NC 8 NC 9 NC 10 SSD_LED 11 GND 12 Connector Key 13 Connector Key 14 Connec...

Страница 30: ...PERST 51 GND 52 CLKREQ 53 REFCLKN 54 PEWAKE 55 REFCLKP 56 NC 57 GND 58 NC 59 NC 60 NC 61 NC 62 NC 63 NC 64 NC 65 NC 66 NC 67 NC 68 NC 69 NC 70 3 3V 71 GND 72 3 3V 73 GND 74 3 3V 75 GND 3 3 9 SIM Card...

Страница 31: ...Pin 128 of NVIDIA Jetson Xavier NX Pin Signal Pin Signal 1 WAKE 2 3 3V 3 No use 4 GND 5 No use 6 1 5V 7 CLKREQ 8 No use 9 GND 10 No use 11 REFCLK 12 No use 13 REFCLK 14 No use 15 GND 16 No use 17 No u...

Страница 32: ...AIE800 904 FL Series User s Manual 24 Jumper Connector Settings This page is intentionally left blank...

Страница 33: ...he Linux host system is running x86_64 Ubuntu v18 04 please follow the instruction below to install Python first Step 1 Connect the Linux host system to internet Step 2 Install Python with the command...

Страница 34: ...n the host to install the image axiomflash sh The flashing procedure takes approximately 10 minutes or more Upon completion AIE800 904 FL will automatically reboot and please set JP1 to Normal Mode to...

Отзывы: