Characteristics 
 

 

500 counts measurement 

 

ACV and DCV measurements reach up to 1000V 

 

DC measurement accuracy reaches up to 0,1% 

 

0,1 Ω resistance resolution and 10µ V voltage resolution 

 

Linear frequency measurement logic frequency/duty ratio measurement 

 

Capacitance measurement from 0.1 nf to 1000µF 

 

AC/DC true RMS measurement 

 

Maximum value/minimum value measurement 

 

Insulation resistance measurement range: 50K Ω to 2G Ω 

 

Automatic shutdown/continuous working mode selection 

 

Back light control 

 

Overload protection 

 

Secondary plasticizing meter shell, with insulating performance reaching 1000V CAT III 

 

Explanation on Front Panel 

The front panel is shown as in Figure 2-1, explanation being as follows: 
 

Figure 2-1 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

(1) 

Hz

end 

It is the input end for all measurement functions except for current measurement and insulation 
resistance measurement, connected with a red meter probe. Hereinafter referred to as V end. 
(2) COM end 
It is the negative input end for all measurements except for insulation resistance measurement, 
connected with a black meter probe.  
(3) mA/µA end 
It is the positive end for measurement of mA or µA current, connected with a red meter probe.  
It is an end for measurement of the insulation resistance, connected with a black meter probe. 
(4) INS end 
It is the input end for insulation resistance measurement, connected with a red meter probe. 

Содержание AX-TI220

Страница 1: ...AX TI220 OPERATION MANUAL...

Страница 2: ...ere may be ground potential during measuring The body should be kept insulated from ground with dry insulating shoes insulating pads or insulating clothes When performing measurement with a test probe...

Страница 3: ...mance reaching 1000V CAT III Explanation on Front Panel The front panel is shown as in Figure 2 1 explanation being as follows Figure 2 1 1 V Hz end It is the input end for all measurement functions e...

Страница 4: ...key the meter will enter the linear frequency measurement state At this time what being measured is the frequency of voltage or current By pressing this key again to exit the linear frequency measurem...

Страница 5: ...easurement unit being or F of temperature or F or nF of Capacitance mAV Indicating the measurement unit being A mA of current or V and mV of voltage KHz Indicating the measurement unit being KHz and H...

Страница 6: ...ng the range of excitation voltage when performing the insulation resistance measurement 15 TEST Indicating it is now in the insulation resistance measurement state 16 Indication to low voltage of the...

Страница 7: ...sistance measurement state press the TEST key to start measuring and then press the TEST key again to stop measuring The measurement range of the insulation resistance is 50K 2G Maximum minimum value...

Страница 8: ...y 0 50 Storage temperature 20 60 relative humidity 80 Altitude operation less than 2000m Storage less than 10000m Volume 200mm X 100mm X 40mm Weight 560g Range and Accuracy The below listed accuracies...

Страница 9: ...0 8 4 102 V A 5000 A 1 A 0 8 4 50mA 10 A 0 8 4 1 5mV mA 500mA 0 1mA 0 8 4 Notes above accuracies can be guaranteed within 10 100 of the full range DC Current Range Resolution Accuracy Voltage Drop 500...

Страница 10: ...nF 2 10 50 F 10nF 2 10 500 F 0 1 F 2 10 1000 F 1 F 3 10 Notes above accuracies for film capacitor or better can be guaranteed within the full range Diode Range Resolution Accuracy 2 5V 1mV 1 5 Notes t...

Страница 11: ...1000V 400V 5000 A 1mA 500mA 100mA Notes Low voltage or low frequency would lower the accuracy Duty Ratio Frequency Range Duty Ratio Range Resolution Accuracy 5Hz 500KHz 5 95 0 01 0 02 Insulation Resis...

Страница 12: ...in the batteries as the polarity specified on the shell of the meter Put the cover as its origin The meter must not be used until the cover of batteries being put properly and locked in Replacement o...

Отзывы: