background image

 

 

 

 

 

 

DC POWER SUPPLY 

 

AX-3003D, AX-3005D, 

AX-1803D 

 

 

 

 

 

USERS MANUAL 

 

V

C. V.

I NE

COARSE

VOLTAGE

A

V

OFF

+

_

ON

VOLTAGE

CURRENT

DC POWER 

SUPPLY

F I N

COARSE

F I N E

C RRENT

C. C.

O ER

O

ON

Содержание AX-1803D

Страница 1: ...DC POWER SUPPLY AX 3003D AX 3005D AX 1803D USERS MANUAL V C V I N E C O AR SE VO LTAG E A V OFF _ ON VOLTAGE CURRENT DC POWER SUPPLY F I N C O AR SE F I N E C R R EN T C C O ER O O N...

Страница 2: ...recautions 4 Safety Information 4 Safety Symbols 4 Instrument Front Panel 5 Instrument Back Panel 6 2 Operation 7 Line Power Supply Setting 8 Operation Procedure 8 3 Specifications 10 General Specific...

Страница 3: ...ypes for the power supply series monitoring output voltage and current They are LCD LED and two pointer meters One of them is equipped to the DC power supply There are different numbers of output volt...

Страница 4: ...taking electrical measurements Keep your body isolated from ground by using dry clothing rubber shoes rubber mat or any approved insulating material 5 Never touch exposed wiring connections or any liv...

Страница 5: ...1 1 OUTPUT VOLTAGE INDICATOR This indicator shows output voltage as measured at the output terminals There is LCD or LED or pointer meter display type They are available for choice of user 2 OUTPUT C...

Страница 6: ...only pointer meter display Each pointer meter has a mechanical screw adjustment for setting the zero point Using a small screwdriver turn off the power and adjust the screw under the meter respective...

Страница 7: ...with same the power requirements of instrument before connect power cord to live power source WARNING To avoid electrical shock disconnect power cord from live power source and remove the test leads...

Страница 8: ...50Hz 60Hz NOTE The instrument without POWER SELECT SWITCH is factory pre set in accordance with your main voltage when your local distributor place the order with the factory Operating Procedure CONST...

Страница 9: ...rrent level at which the restricted current protection will be active as you desire 6 Remove the wire linked to the positive and negative output terminals Connect the positive output terminal and nega...

Страница 10: ...ous upward of 75 rate output power for one hour Relative Humidity 20 to 80 RH 0 to 40 Protection constant current and short circuit protection Weight Size OUTPUT VOLTAGE regulated OUTPUT CURRENT regul...

Страница 11: ...0 2A 0 3A 0 18V 0 2A 0 3A 0 30V 0 2A 0 3A 0 5A 0 10A 0 20A 0 50V 0 2A 0 3A Source Effect Line regulation CV 0 01 1mV CC 0 2 1mA Loading Effect Line regulation CV 0 01 3mV CC 0 2 3mA Ripple nad noise C...

Страница 12: ...TO V CAUTION WARNING Turn off the power switch remove the power line cord from the power socket and disconnect the test leads at output terminals before replacing the fuse Replace it only with same ty...

Отзывы: