7.6.2 OSW setup
Light barriers adaptation is done through the Test mode. The adaptation is not continuously made to avoid useless reader’s stops. The below
operation can be done only during a maintenance service and by trained technicians.
•
No document or paper present in the input tray or in the transport mechanism
•
Press the key
2
for
OSW setup
•
OSW are automatically set and keep the setting till the next switch calibration
•
Values are displayed
•
00, OSW. is not working or not connected
•
06-98, OSW is optimum
•
99, OSW is working but the safety margin is low