UM AX032200 Version 1.0 36-46
3.10. Conditional Block Setpoints
The Conditional Block setpoints are defined in Section1.11. Refer to that section for detailed
information on how these setpoints are used. The screen capture in Figure 14 displays the
available setpoints for each of the Conditional Blocks. The table below the screen capture
highlights the allowable ranges for each setpoint.
Figure 14: Screen Capture of Conditional Block Setpoints
Name
Range
Default
Notes
Conditional Function Enabled
Drop List
Disabled
Condition 1 Argument 1 Source
Drop List
Digital Input Refer to Table 1
Condition 1 Argument 1 Number
Depends on Source Selected 0
Refer to Table 1
Condition 1 Argument 2 Source
Drop List
Digital Input Refer to Table 1
Condition 1 Argument 2 Number
Depends on Source Selected 0
Refer to Table 1
Condition 1 Operator (Argument 1/2)
Drop List
0
Refer to Table 15
Condition 2 Argument 1 Source
Drop List
Digital Input Refer to Table 1
Condition 2 Argument 1 Number
Depends on Source Selected 0
Refer to Table 1
Condition 2 Argument 2 Source
Drop List
Digital Input Refer to Table 1
Condition 2 Argument 2 Number
Depends on Source Selected 0
Refer to Table 1
Condition 2 Operator (Argument 1/2)
Drop List
0
Refer to Table 15
Conditional Result Operator
Drop List
OR
Refer to Table 16
Table 26: Default Conditional Block Setpoints