No Sound and the 

Amplifier gets too hot

•  The amplifier temperature protections trips, re-locate the amplifier in a more ventilated location.

No Sound and 

Protection trip

(LED PROTECT always 

on)

•  Could be a possible short circuit at the amplifier loudspeakers outputs, the speaker’s inputs or in the cabling. Locate 

and remove the short circuit.

•  The impedance of the loudspeakers connected is too low. Use a speaker with a minimum impedance of 4Ω (8Ω in 

the Bridge mode).

•  If no load connected the protection trips the same, a DC voltage has been detected in the amplifier’s output circuit 

and you have to contact you nearest service assistance center to repair the amplifier.

CE CONFORMITY

•  Proel products comply with directive 2014/30/CE (EMC), as stated in EN 55103-1 and EN 55103-2 standards and with directive 2014/35/CE 

(LVD), as stated in EN 60065 standard.

•  Under the EM disturbance, the ratio of signal-noise will be changed above 10dB.

PACKAGING, SHIPPING AND COMPLAINT

•  This unit package has been submitted to ISTA 1A integrity tests. We suggest you control the unit conditions immediately after unpacking it.

•  If any damage is found, immediately advise the dealer. Keep all unit packaging parts to allow inspection.

•  Proel is not responsible for any damage that occurs during shipment.

•  Products are sold “delivered ex warehouse” and shipment is at charge and risk of the buyer.

•  Possible damages to unit should be immediately notified to forwarder. Each complaint for package tampered with should be done within eight 

days from product receipt.

WARRANTY AND PRODUCTS RETURN

•  Proel products have operating warranty and comply their specifications, as stated by manufacturer.

•  Proel warrants all materials, workmanship and proper operation of this product for a period of two years from the original date of purchase. If 

any defects are found in the materials or workmanship or if the product fails to function properly during the applicable warranty period, the owner 

should inform about these defects the dealer or the distributor, providing receipt or invoice of date of purchase and defect detailed description. 

This warranty does not extend to damage resulting from improper installation, misuse, neglect or abuse. Proel S.p.A. will verify damage on returned 

units, and when the unit has been properly used and warranty is still valid, then the unit will be replaced or repaired. Proel S.p.A. is not responsible 

for any "direct damage" or "indirect damage" caused by product defectiveness.

INSTALLATION AND DISCLAIMER

•  Proel products have been expressly designed for audio application, with signals in audio range (20Hz to 20kHz). Proel has no liability for damages 

caused in case of lack of maintenance, modifications, improper use or improper installation non-applying safety instructions.

•  These amplifiers are adapted in a properly ventilated, standard professional 19" rack. These units feature ventilation holes on the front and 

back panels. Absolutely do not obstruct the ventilation holes. Blocked ventilation can cause damages and fire. 

•  Do not locate sensitive high-gain equipment such as mixer, preamplifiers, recorders or AD/DA conversion units directly above or below these 

amplifiers. Because these amplifiers have a high power density, it ha a strong magnetic field which can induce hum into unshielded devices that 

are located nearby. If an equipment rack is used, we recommend locating the amplifier in the bottom of the rack and the mixer, preamplifier or 

other sensitive equipment at the top.

•  Proel S.p.A. reserves the right to change these specifications at any time without notice.

•  Proel S.p.A. declines any liability for damages to objects or persons caused by lacks of maintenance, improper use, installation not performed 

with safety precautions and at the state of the art.

POWER SUPPLY AND MAINTENANCE

•  Clean only with dry cloth.

•  Check periodically that the slots for its proper ventilation and heating dissipation are not obstructed by dust, remove the dust using a dry brush 

or a compressed air gun.

•  The QC4.2, QC4.4 and QC2.4 amplifiers of Proel have been designed with CLASS I construction and must be connected always to a mains socket 

outlet with a protective earth connection (the third grounding prong).

•  Before connecting the product to the mains outlet make certain that the mains line voltage matches that shown on the rear of the product, a 

tolerance of up to ±10% is acceptable.

•  To disconnect these equipment from the AC Mains, disconnect the power supply cord plug from the AC mains outlet.

•   THE REPLACEMENT OF FUSES INSIDE THE APPARATUS MUST BE MADE ONLY BY QUALIFIED PERSONNEL.

•   CHECK THE CONDITION OF THE PROTECTION FUSE, ACCESSIBLE OUTWARD, ONLY WITH THE APPARATUS SWITCHED OFF AND DISCONNECTED 

FROM THE MAINS LINE OUTLET.

•   REPLACE THE PROTECTION FUSE ONLY WITH SAME TYPE AS SHOWN ON THE PRODUCT.

•   IF AFTER THE SUBSTITUTION, THE FUSE INTERRUPTS AGAIN THE APPARATUS WORKING, DO NOT TRY AGAIN THEN CONTACT THE PROEL 

SERVICE CENTRE.

Содержание QC2.4

Страница 1: ...QC series QC4 2 QC4 4 QC2 4 Digitally Controlled Class D Power Amplifiers with SMPS DSP USER MANUAL ...

Страница 2: ...stitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All right...

Страница 3: ...r Supply 230 V or 120 V 50 60 Hz Max Consumption 2900 W 5300 W 1800 W Rated Consumption 800 W 1350 W 600 W Weight 11 Kg 24 3 lb 12 Kg 26 5 lb Dimensions W x H x D 483 x 89 x 383 mm 19 x 3 5 x 16 2 inch 483 x 89 x 463 mm 19 x 3 5 x 18 2 inch Standard EIA 1KHz THD 1 Rated consumption is measured with pink noise with a crest factor of 12 dB this can be considered a standard music program With PFC cir...

Страница 4: ...permissible line lengths for 0 5dB losses voltage or spl 4 ohm load 8 ohm load Wire section data PROEL recommended cables feet meter feet meter mm AWG 2 wires 4 wires 2 wires Fire resistant 125 40 250 80 6 0 10 HPC626 75 25 150 50 4 0 12 HPC624 HPC644 HPC624FRS 50 17 5 100 35 2 0 14 HPC620 HPC640 HPC620FRS 30 10 60 20 1 5 16 HPC610 HPC610FRS this is a short extraction of the wide assortment of cab...

Страница 5: ... are equal to channel 1 and 2 respectively 2 channel 2 positive 2 LINK Balanced female XLR ground hot cold INPUT Jack balanced PROEL code NL4FX PROEL code NL4FX SPEAKER POWER OUTPUTS Neutrik NL4 Speakon Cable Connector INPUT Jack unbalanced note connect both cold and ground to make cable from balanced to unbalanced 2 1 2 1 20mm 0 8 8mm 0 3 RED BLACK positive red rosso n c 1 negative black nero 1 n...

Страница 6: ... FRONT PANEL FIG 5 ...

Страница 7: ...AS OUVRIR WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE INPUT NON OSTRUIRE 1 INPUT 1 2 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE INPUT IMPEDANCE 10K BALANCED INPUT IMPEDANCE 10K BALANCED MAINS 2 GND LIFT OUTPUTS 1 1 CH1 1 CH1 2 CH2 2 CH2 2 1 CH2 1 CH2 B 1 1 K E PAS OUVRIR E OR ELECTRIC SHOCK IN OR MOISTURE NON OSTRUIRE 1 INPUT 1 2 MIN LOAD 4Ω ...

Страница 8: ...H4 set as GANGED set as GANGED set as GANGED OUT3 WF1 OUT4 WF2 IN3 IN4 nc Gain Reduct PARALLEL MODE 3 EXAMPLE A INPUT DO NOT COVER NON OSTRUIRE 1 INPUT 3 4 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE 1 2 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE INPUT IMPEDANCE 10K BALANCED INPUT IMPEDANCE 10K BALANCED INPUT 4 3 INPUT GND LIFT MAINS DESIGNED ENGINEERED BY PROEL 2 GND LIFT INPUT DO NOT COVER NON OS...

Страница 9: ...IDGE OUT C IN1 IN2 IN3 IN4 nc Gain Reduct 0 Gain Reduct 0 STEREO MODE BRIDGE MODE 3 set as GANGED set as GANGED INPUT DO NOT COVER NON OSTRUIRE 1 INPUT 3 4 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE 1 2 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE INPUT IMPEDANCE 10K BALANCED INPUT IMPEDANCE 10K BALANCED INPUT 4 3 INPUT GND LIFT MAINS DESIGNED ENGINEERED BY PROEL 2 GND LIFT INPUT DO NOT COVER NON OS...

Страница 10: ... equipment capable of producing high sound pressure levels use hearing protectors while the equipment is in operation Ear plugs or protectors in the ear canals or over the ears must be worn when operating the equipment in order to prevent permanent hearing loss if exposure is in excess of the limits set forth here Keep your s attention that children and pets are more susceptible to excessive noise...

Страница 11: ...ired Proel S p A is not responsible for any direct damage or indirect damage caused by product defectiveness INSTALLATION AND DISCLAIMER Proel products have been expressly designed for audio application with signals in audio range 20Hz to 20kHz Proel has no liability for damages caused in case of lack of maintenance modifications improper use or improper installation non applying safety instructio...

Страница 12: ... and CLIP LIMITER circuit CONTROLS AND CONNECTIONS 1 Power switch and Power indicator Amplifier is ON when the switch is in the I position The Blue LED indicates amplifier has been turned on 2 RESET BUTTON This button can be used to reset the QC amplifier s DSP for service operations Use a paper clip rod to press and hold this button when powering the amplifier ON this will perform a reset of the ...

Страница 13: ...ing negative or cold Sleeve shield or ground When connecting an unbalanced signal wire them as follows Pin2 Tip positive or hot Pin 1 3 Sleeve shield or ground NOTE whenever possible use always balanced cables Unbalanced lines may also be used but may result in noise over long cable runs In any case avoid using a balanced cable for one channel and an unbalanced one for the other 14 LINK This is a ...

Страница 14: ...omproaudio com clicking on downloads section of the product To connect QC amplifiers to a PC running PRONET control software the network connectors on the front panel and PROEL USB2CAN or USB2CAND converters optional must be used The first time you connect a device with the USB2CAN converter Windows O S will ask you to install the driver files which you can find in the Driver folder within the Pro...

Страница 15: ...lifiers can operate alone without the PC control software All the features of the built in CORE DSP are described in the PRONET user s manual included with the software see HELP menu so in this manual only a few peculiarity of the QC amplifiers architecture are explained Routing Signals To start it s important to understand QC signal routing Each QC amplifier has 2 or 4 physical inputs each of the...

Страница 16: ...1 The speaker power handling PAES measured with the AES2 1984 r2003 standard AES Recommended Practice Specification of loudspeaker components used in professional audio and sound reinforcement usually it is indicated in the speaker technical data in WAES this standard is actually the best method to know the power handling capability of the speaker for a standard music program In case of a group of...

Страница 17: ...ɏ ϭϬϬϬt ϴɏ ϭϬϬϬt ϰɏ ϮϬϬϬt ϴɏ ϮϬϬϬt ϰɏ ϰϬϬϬt ϴɏ 25 13 0 16 0 19 0 50 10 0 13 0 16 0 75 8 2 11 2 14 3 100 7 0 10 0 13 0 150 5 2 8 2 11 2 200 4 0 7 0 10 0 250 3 0 6 0 9 0 300 2 2 5 2 8 2 350 1 5 4 6 7 6 400 1 0 4 0 7 0 450 0 5 3 5 6 5 500 0 0 3 0 6 0 600 2 2 5 2 700 1 5 4 6 800 1 0 4 0 900 0 5 3 5 1000 0 0 3 0 1250 2 0 1500 1 2 1750 0 6 2000 0 0 25 10 0 16 0 13 0 19 0 16 0 22 0 50 7 0 13 0 10 0 16 0 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...REV 40 15 CODE 96MAN0105 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com ...

Отзывы: