Axiom QC2.4 Скачать руководство пользователя страница 10

10

SAFETY AND PRECAUTIONS

•   

CAUTION:

 before using this product read carefully the following safety instructions. Take a look of this manual entirely and preserve it for 

future reference.

  When using any electric product, basic precautions should always be taken, including the following:

–  To reduce the risk, close supervision is necessary when the product is used near children.

–  Protect the apparatus from atmospheric agents and keep it away from water, rain and high humidity places.

–  This product should be site away from heat sources such as radiators, lamps and any other device that generate heat. 

–  This product should be located so that its location or position does not interfere with its proper ventilation and heating dissipation. 

–  Care should be taken so that objects and liquids do not go inside the product.

–  The product should be connected to a power supply mains line only of the type described on the operating instructions or as marked on the 

product. Connect the apparatus to a power supply using only power cord included making always sure it is in good conditions.

–   

WARNING:

 The mains plug is used as disconnect device, the disconnect device shall remain readily operable.

–  Do not cancel the safety feature assured by means of a polarized line plug (one blade wider than the other) or with a earth connection.

–  Make sure that power supply mains line has a proper earth connection.

–  Power supply cord should be unplugged from the outlet during strong thunderstorm or when left unused for a long period of time.

–  Do not place objects on the product’s power cord or place it in a position where anyone could trip over, walk on or roll anything over it. Do not 

allow the product to rest on or to be installed over power cords of any type. Improper installations of this type create the possibility of fire hazard 

and/or personal injury.

–  This  product  may  be  capable  of  producing  sound  levels  that  could  cause 

permanent  hearing  loss.  Exposure  to  extremely  high  noise  levels  may  cause 

permanent hearing loss. Individuals vary considerably in susceptibility to noise-

induced hearing loss, but nearly everyone will lose some hearing if exposed 

to  sufficiently  intense  noise  for  a  period  of  time.  The  U.S.  Government’s 

Occupational  Safety  and  Health  Administration  (OSHA)  has  specified  the 

permissible noise level exposures shown in the following chart. According to 

OSHA, any exposure in excess of these permissible limits could result in some 

hearing loss. To ensure against potentially dangerous exposure to high sound 

pressure  levels,  it  is  recommended  that  all  persons  exposed  to  equipment 

capable of producing high sound pressure levels use hearing protectors while 

the equipment is in operation. Ear plugs or protectors in the ear canals or over 

the  ears  must  be  worn  when  operating  the  equipment  in  order  to  prevent 

permanent hearing loss if exposure is in excess of the limits set forth here. Keep 

your's attention that children and pets are more susceptible to excessive noise 

levels.

IN CASE OF FAULT

•  In case of fault or maintenance this product should be inspected only by qualified service personnel when:

–  There is a flaw either in the connections or in the supplied connecting cables.

–  Liquids have spilled inside the product.

–  The product has fallen and been damaged.

–  The product does not appear to operate normally or exhibits a marked change in performance.

–  The product has been lost liquids or gases or the enclosure is damaged.

•  Do not operate on the product, it has no user-serviceable parts inside, refer servicing to an authorized maintenance centre.

TROUBLESHOOTING

No Power

•  The amplifier's "POWER" switch is off.

•  Make sure the mains AC outlet is live (check with a tester or a lamp).

•  Make sure the mains plug is securely plugged into mains AC outlet.

No Sound

•  Is the input LEVEL control for the channel turned up?

•  Is the SIGNAL LED illuminated? If not check if your signal level is too low or check the signal cable, mixer and other 

equipment setting and cabling.

•  Are you sure your signal cables works properly? check it using a cable tester or replacing with a new one.

•  Is the SPEAKON cable connector correctly inserted? turn it clockwise until it clicks.

•  Are you sure your power cable works properly? check it using a cable tester or replacing with a new one.

Distorted Sound

•  Input signal level is too high. Turn down your level controls.

NOTE:  The  loudspeakers  should  never  be  operated  at  a  level  which  causes  the  amplifier  Clip  LEDs  to  illuminate 

constantly.

Different channel 

level

•  Check if are using a balanced cable for one channel and an unbalanced one for the other, as this would cause a 

considerable difference in channel levels.

•  Be sure that your loudspeaker system is fully connected and both loudspeakers have the same impedance.

Noise / Hum

•  Enable GND LIFT button on rear panel, if the problem persist press all GND LIFT buttons for all system's amplifiers.

•  Whenever possible, preferably use only balanced cables. Unbalanced lines may also be used but may result in noise 

over long cable runs. 

•  Sometimes it helps to plug all audio equipment into the same AC circuit so they share a common ground.

Duration Per Day

In Hours

Sound Level dBA

Slow Response

Typical

Example

8

90

Duo in small club

6

92

4

95

Subway Train

3

97

2

100

Very loud classical music

1.5

102

1

105

Traffic noise

0.5 

110

0.25 or less

115

Loudest parts at a rock concert

Содержание QC2.4

Страница 1: ...QC series QC4 2 QC4 4 QC2 4 Digitally Controlled Class D Power Amplifiers with SMPS DSP USER MANUAL ...

Страница 2: ...stitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance The information contained in this publication has been carefully prepared and checked However no responsibility will be taken for any errors All right...

Страница 3: ...r Supply 230 V or 120 V 50 60 Hz Max Consumption 2900 W 5300 W 1800 W Rated Consumption 800 W 1350 W 600 W Weight 11 Kg 24 3 lb 12 Kg 26 5 lb Dimensions W x H x D 483 x 89 x 383 mm 19 x 3 5 x 16 2 inch 483 x 89 x 463 mm 19 x 3 5 x 18 2 inch Standard EIA 1KHz THD 1 Rated consumption is measured with pink noise with a crest factor of 12 dB this can be considered a standard music program With PFC cir...

Страница 4: ...permissible line lengths for 0 5dB losses voltage or spl 4 ohm load 8 ohm load Wire section data PROEL recommended cables feet meter feet meter mm AWG 2 wires 4 wires 2 wires Fire resistant 125 40 250 80 6 0 10 HPC626 75 25 150 50 4 0 12 HPC624 HPC644 HPC624FRS 50 17 5 100 35 2 0 14 HPC620 HPC640 HPC620FRS 30 10 60 20 1 5 16 HPC610 HPC610FRS this is a short extraction of the wide assortment of cab...

Страница 5: ... are equal to channel 1 and 2 respectively 2 channel 2 positive 2 LINK Balanced female XLR ground hot cold INPUT Jack balanced PROEL code NL4FX PROEL code NL4FX SPEAKER POWER OUTPUTS Neutrik NL4 Speakon Cable Connector INPUT Jack unbalanced note connect both cold and ground to make cable from balanced to unbalanced 2 1 2 1 20mm 0 8 8mm 0 3 RED BLACK positive red rosso n c 1 negative black nero 1 n...

Страница 6: ... FRONT PANEL FIG 5 ...

Страница 7: ...AS OUVRIR WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE INPUT NON OSTRUIRE 1 INPUT 1 2 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE INPUT IMPEDANCE 10K BALANCED INPUT IMPEDANCE 10K BALANCED MAINS 2 GND LIFT OUTPUTS 1 1 CH1 1 CH1 2 CH2 2 CH2 2 1 CH2 1 CH2 B 1 1 K E PAS OUVRIR E OR ELECTRIC SHOCK IN OR MOISTURE NON OSTRUIRE 1 INPUT 1 2 MIN LOAD 4Ω ...

Страница 8: ...H4 set as GANGED set as GANGED set as GANGED OUT3 WF1 OUT4 WF2 IN3 IN4 nc Gain Reduct PARALLEL MODE 3 EXAMPLE A INPUT DO NOT COVER NON OSTRUIRE 1 INPUT 3 4 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE 1 2 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE INPUT IMPEDANCE 10K BALANCED INPUT IMPEDANCE 10K BALANCED INPUT 4 3 INPUT GND LIFT MAINS DESIGNED ENGINEERED BY PROEL 2 GND LIFT INPUT DO NOT COVER NON OS...

Страница 9: ...IDGE OUT C IN1 IN2 IN3 IN4 nc Gain Reduct 0 Gain Reduct 0 STEREO MODE BRIDGE MODE 3 set as GANGED set as GANGED INPUT DO NOT COVER NON OSTRUIRE 1 INPUT 3 4 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE 1 2 MIN LOAD 4Ω MIN LOAD 8Ω MIN LOAD 4Ω BRIDGE INPUT IMPEDANCE 10K BALANCED INPUT IMPEDANCE 10K BALANCED INPUT 4 3 INPUT GND LIFT MAINS DESIGNED ENGINEERED BY PROEL 2 GND LIFT INPUT DO NOT COVER NON OS...

Страница 10: ... equipment capable of producing high sound pressure levels use hearing protectors while the equipment is in operation Ear plugs or protectors in the ear canals or over the ears must be worn when operating the equipment in order to prevent permanent hearing loss if exposure is in excess of the limits set forth here Keep your s attention that children and pets are more susceptible to excessive noise...

Страница 11: ...ired Proel S p A is not responsible for any direct damage or indirect damage caused by product defectiveness INSTALLATION AND DISCLAIMER Proel products have been expressly designed for audio application with signals in audio range 20Hz to 20kHz Proel has no liability for damages caused in case of lack of maintenance modifications improper use or improper installation non applying safety instructio...

Страница 12: ... and CLIP LIMITER circuit CONTROLS AND CONNECTIONS 1 Power switch and Power indicator Amplifier is ON when the switch is in the I position The Blue LED indicates amplifier has been turned on 2 RESET BUTTON This button can be used to reset the QC amplifier s DSP for service operations Use a paper clip rod to press and hold this button when powering the amplifier ON this will perform a reset of the ...

Страница 13: ...ing negative or cold Sleeve shield or ground When connecting an unbalanced signal wire them as follows Pin2 Tip positive or hot Pin 1 3 Sleeve shield or ground NOTE whenever possible use always balanced cables Unbalanced lines may also be used but may result in noise over long cable runs In any case avoid using a balanced cable for one channel and an unbalanced one for the other 14 LINK This is a ...

Страница 14: ...omproaudio com clicking on downloads section of the product To connect QC amplifiers to a PC running PRONET control software the network connectors on the front panel and PROEL USB2CAN or USB2CAND converters optional must be used The first time you connect a device with the USB2CAN converter Windows O S will ask you to install the driver files which you can find in the Driver folder within the Pro...

Страница 15: ...lifiers can operate alone without the PC control software All the features of the built in CORE DSP are described in the PRONET user s manual included with the software see HELP menu so in this manual only a few peculiarity of the QC amplifiers architecture are explained Routing Signals To start it s important to understand QC signal routing Each QC amplifier has 2 or 4 physical inputs each of the...

Страница 16: ...1 The speaker power handling PAES measured with the AES2 1984 r2003 standard AES Recommended Practice Specification of loudspeaker components used in professional audio and sound reinforcement usually it is indicated in the speaker technical data in WAES this standard is actually the best method to know the power handling capability of the speaker for a standard music program In case of a group of...

Страница 17: ...ɏ ϭϬϬϬt ϴɏ ϭϬϬϬt ϰɏ ϮϬϬϬt ϴɏ ϮϬϬϬt ϰɏ ϰϬϬϬt ϴɏ 25 13 0 16 0 19 0 50 10 0 13 0 16 0 75 8 2 11 2 14 3 100 7 0 10 0 13 0 150 5 2 8 2 11 2 200 4 0 7 0 10 0 250 3 0 6 0 9 0 300 2 2 5 2 8 2 350 1 5 4 6 7 6 400 1 0 4 0 7 0 450 0 5 3 5 6 5 500 0 0 3 0 6 0 600 2 2 5 2 700 1 5 4 6 800 1 0 4 0 900 0 5 3 5 1000 0 0 3 0 1250 2 0 1500 1 2 1750 0 6 2000 0 0 25 10 0 16 0 13 0 19 0 16 0 22 0 50 7 0 13 0 10 0 16 0 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ...REV 40 15 CODE 96MAN0105 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com ...

Отзывы: