• Accessories: 20A test leads, user manual, temperature probe, holster, gift box, and 9V battery.
2.2. Technical characteristics
2.2.1. Accuracy
± (a% of the r least significant bit); guaranteed accurate ambient temperature: (23±5)° C; relative
humidity: <75%; guaranteed calibration period: one year since the date of delivery.
2.2.2. DC voltage measurement
Range / Accuracy / Resolution
200mV / ±(0.1%+5) / 0.01mV
2V / ±(0.1%+5) / 0.1mV
20V / ±(0.1%+5) / 1mV
200V / ±(0.1%+5) / 10mV
1000V / ±(0.2%+5) / 100mV
Input impedance: 200mV:1MΩ, other range is 10MΩ;
Over load protection: 250V DC or AC peak value for range 200mV; 1000V DC or AC peak value for other
ranges.
2.2.3. AC Voltage Measurement
Range / Accuracy / Resolution
200mV / ±(0.8%+25) / 0.01mV
2V / ±(0.8%+25) / 0.1mV
20V / ±(0.8%+25) / 1mV
200V / ±(0.8%+25) / 10mV
750V / ±(1.0%+25) / 100mV
Input impedance: 200mV range: 1MΩ and the other is 10 MΩ;
Overload protection: DC1000V or AC750V peak value;
Frequency response: The frequency scope for all ranges is 40Hz – 1kHz (applicable to standard sine wave
and triangle wave).
Display: Sine wave RMS (Average value response)
2.2.4. DC current measurement
Range / Accuracy / Resolution
200uA / ±(0.8%+5) / 0.01uA
2mA / ±(0.8%+5) / 0.1uA
20mA / ±(0.8%+5) / 1uA
200mA / ±(0.8%+5) / 10uA
20A / ±(2.0%+15) / 1mA