Non-Contact AC Voltage Measurements 

 

 

 

1.

 

Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. 

2.

 

If AC voltage is present, the detector light will illuminate. 

NOTE

: The conductors in electrical cord sets are often twisted. For best results, rub the probe tip 

along a length of the cord to assure placing the tip in close proximity to the live conductor. 

NOTE

: The detector is designed with high sensitivity. Static electricity or other sources of energy 

may randomly trip the sensor. This is normal operation 
 

MODE BUTTON 

To select DC/ACV,OHM/ Diode/Continuity 

 

Data Hold Button 

To freeze the LCD meter reading, press the data hold button. The data hold button is located on the 
left side of the meter (top button). While data hold is active, the 

HOLD 

display icon appears on the 

LCD. Press the data hold button again to return to normal operation. 

 

MAX Hold Button 

The max. Hold position is used to measure the maximum value. The maximum measured value is up 
dated continuously. Press once again the button, will release the hold and allow a further 
measurement. 

 

RANGE BUTTON 

When the meter is first turned on, it automatically goes into AutoRanging. This automatically 
selects the best range for the measurements being made and is generally the best mode for most 
measurements. For measurement situations requiring that a range be manually selected, perform 
the following: 

1. Press the RANGE button. The “Auto Range” display indicator will turn off, The “Manual Range” 
display indicator will turn on 
2. Press the RANGE button to step through the available ranges until you select the range you want. 
3. Press and hold the RANGE button for 2 seconds to 
exit the ManualRanging mode and return to AutoRanging. 
 

Battery Replacement 
1.

 

Remove the one rear Phillips head screw 

2.

 

Open the battery compartment 

3.

 

Replace the Requires One 9V Battery.  

4.

 

Re-assemble the meter 

WARNING: 

 Risk of Electrocution. Before use, always test the Voltage Detector on a known live 

circuit to verify proper operation 