6
1.
Set the Function switch to the
400.0A ~ 2.000A
range.
2.
If the range of the measured is not known,
select the higher range first then move to the lower
range if necessary.
3.
Press the trigger to open jaw. Fully enclose one conductor to be measured.
The clamp meter LCD will display the reading.
DC/AC Voltage Measurements
1.
Insert the black test lead into the negative
COM
terminal and the red test lead into the positive
V
terminal.
2.
Set the function switch to the V position.
3.
Select AC or DC with the
MODE
button.
4.
Connect the test leads in parallel to the circuit under test.
5.
Read the voltage measurement on the LCD display.
Resistance Measurements
1.
Insert the black test lead into the negative
COM
terminal and the
red test lead into the positive terminal.
2.
Set the function switch to the
•)))
position.
3.
Touch the test probe tips across the circuit or component under test. It is best to disconnect one
side of the device under test so the rest of the circuit will not interfere with the resistance reading.
4.
For Resistance tests, read the resistance on the LCD display.
Diode and Continuity Measurements
1.
Insert the black test lead banana plug into the negative COM jack and the red test lead banana
plug into the positive diode jack.
2.
Turn the rotary switch to the
•))) position.
3.
Press the MODE button until “
“ appears in the display.
4.
Touch the test probes to the diode under test. Forward voltage will indicate 0.4V to 0.7V.
Reverse voltage will indicate “OL”. Shorted devices will indicate near 0mV and an open device will
indicate “OL” in both polarities.
For Continuity tests, if the resistance is < 150, a tone will sound.
Red Black Black Red
Probe Probe Probe Probe
Forward test Reverse test