background image

Manufacturer

AXING AG 

Gewerbehaus Moskau

 8262 Ramsen

EEA contact address

Bechler GmbH

Am Rebberg 44

 78239 Rielasingen

State of the art 2018-08-17

Technical improvements, changes in design, printing- and other errors expected.

Safety advices:

 

Installation and repairs to the equipment may only be carried out by 
technicians observing the current VDE guidelines. No liability will be 
assumed in the case of faulty installation and commissioning.

 

Before opening the equipment pull out the power plug or remove the 
power supply, otherwise there is danger of electrocution. This is also 
valid for cleaning the equipment or working on the connections. 

 

Only use the mains cable connected to the device. Never replace any 
parts or make any modifications on the mains cable. Otherwise there is a 
risk of mortal injury for which we cannot be held liable.

 

Providing that a serviceable fuse exists, the power plug must be pulled 
out before changing the fuse. Defective fuses may only be replaced with 
standard compliant fuses that have the same nominal value.

 

The equipment may only be operated in dry rooms. In humid rooms or 
outdoors there is danger of short-circuit (caution: risk of fire) or  
electrocution.

 

To prevent damage to your equipment and to avoid possible peripheral 
damages, the devices foreseen for wall mounting may only be installed 
on a flat surface.

 

Choose the location of installation or mounting so that the power plug 
can be reached and pulled out of the socket easily in case of danger. 
Choose the location of installation or mounting such that children may 
not play unsupervised near the equipment and its connections. The 
location of installation or mounting must allow a safe installation of all 
cables connected. The mains cable as well as feeder lines may not be 
damaged or clamped by objects of any kind. 

 

Choose the location of installation or mounting so that under no  
circumstances liquids or objects can get into the equipment (e.g.  
condensation, water coming from leaking roofs or flowing water, etc.).

 

Avoid exposure of the equipment to direct sunlight and to other heat 
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices 
that are equipped with heat sinks or ventilation slots must under no 
circum-stances be covered or blocked. Also ensure for a generous air 
circulation around the equipment. In this way you avoid possible damage 
to the equipment as well as a risk of fire caused by overheating.  
Absolutely avoid that cables come near any source of heat (e.g.  
radioators, other electrical devices, chimney, etc.).

SPU 1708-06 | SPU 1712-06 
SPU 1716-06 | SPU 1724-06 
SPU 1732-06

basic

-line

Multiswitches / 
Cascade units

Operation instructions

Technical data:

Article

SPU 1708-06

SPU 1712-06

SPU 1716-06

SPU 1724-06

SPU 1732-06

Frequency range (TERR | SA

T)

5…862 MHz | 950…2400 MHz

Number of inputs

17

Number of trunk outputs

17

Subscriber ports

8

12

16

24

32

Tap 

loss TERR

24 dB ±2 dB

28 dB ±3 dB

32 dB ±3 dB

Tap loss SA

T

2...0 dB ±2 dB

3...0 dB ±2 dB

2...0 dB ±2 dB

Max.

 output level subscriber ports SA

T

1

102 dBµV

Switch commands

13/18 

V,

 0/22 kHz,

 DiSEqC 1.0

Through 

loss TERR

3 dB ±1,5 dB

2…5 dB ±1,5 dB

3…5 dB ±1,5 dB

Through loss SA

T

1…2 dB ±1,5dB

1…3 dB ±1,5 dB 

2,5...5 dB ±1,5 dB

Isolation V®H.

>30 dB

Isolation 

TERR input®SA

T. input

30 dB

Ambient temperature range (acc.

 to EN 60065)

-20…+50°C

Current consumption per subscriber port

< 52 mA

Max.

 LNB supply current

1500 mA

Current consumption per subscriber port 

(without LNB supply)

10 mA

Equipotential bonding connection

4 mm2

Dimensions (W × H × D) appr

.

128 x 291 x 63 mm

189 x 291 x 63 mm

308 x 291 x 63 mm

Protection class

IP 20

3rd order SA

T max.

 EN50083-3 35dB KMA (2 Sender Messmethode) 

Herewith AXING AG declares that the marked products comply with the valid 

guidelines. You can call up the complete EU declaration of conformity for 

download by entering the article in the search field at www.axing.com.

WEEE Nr. DE26869279 | Electrical and electronic components must not be 

disposed of as residual waste, it must be disposed of separately.

Отзывы: