Manufacturer
AXING AG
Gewerbehaus Moskau
8262 Ramsen
EEA contact address
Bechler GmbH
Am Rebberg 44
78239 Rielasingen
State of the art 2018-08-17
Technical improvements, changes in design, printing- and other errors expected.
Safety advices:
Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
Before opening the equipment pull out the power plug or remove the
power supply, otherwise there is danger of electrocution. This is also
valid for cleaning the equipment or working on the connections.
Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
Providing that a serviceable fuse exists, the power plug must be pulled
out before changing the fuse. Defective fuses may only be replaced with
standard compliant fuses that have the same nominal value.
The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or
electrocution.
To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
SPU 1708-06 | SPU 1712-06
SPU 1716-06 | SPU 1724-06
SPU 1732-06
basic
-line
Multiswitches /
Cascade units
Operation instructions
Technical data:
Article
SPU 1708-06
SPU 1712-06
SPU 1716-06
SPU 1724-06
SPU 1732-06
Frequency range (TERR | SA
T)
5…862 MHz | 950…2400 MHz
Number of inputs
17
Number of trunk outputs
17
Subscriber ports
8
12
16
24
32
Tap
loss TERR
24 dB ±2 dB
28 dB ±3 dB
32 dB ±3 dB
Tap loss SA
T
2...0 dB ±2 dB
3...0 dB ±2 dB
2...0 dB ±2 dB
Max.
output level subscriber ports SA
T
1
102 dBµV
Switch commands
13/18
V,
0/22 kHz,
DiSEqC 1.0
Through
loss TERR
3 dB ±1,5 dB
2…5 dB ±1,5 dB
3…5 dB ±1,5 dB
Through loss SA
T
1…2 dB ±1,5dB
1…3 dB ±1,5 dB
2,5...5 dB ±1,5 dB
Isolation V®H.
>30 dB
Isolation
TERR input®SA
T. input
30 dB
Ambient temperature range (acc.
to EN 60065)
-20…+50°C
Current consumption per subscriber port
< 52 mA
Max.
LNB supply current
1500 mA
Current consumption per subscriber port
(without LNB supply)
10 mA
Equipotential bonding connection
4 mm2
Dimensions (W × H × D) appr
.
128 x 291 x 63 mm
189 x 291 x 63 mm
308 x 291 x 63 mm
Protection class
IP 20
1
3rd order SA
T max.
EN50083-3 35dB KMA (2 Sender Messmethode)
Herewith AXING AG declares that the marked products comply with the valid
guidelines. You can call up the complete EU declaration of conformity for
download by entering the article in the search field at www.axing.com.
WEEE Nr. DE26869279 | Electrical and electronic components must not be
disposed of as residual waste, it must be disposed of separately.